You have no items in your shopping cart.

Subtotal: $0.00

SmartReader Plus 4 Data Logger: 4 Channels  Pressure, Temperature and 2 for optional RH/Temp Probes

  • SmartReader Plus 4 Data Logger: 4 Channels  Pressure, Temperature and 2 for optional RH/Temp Probes


SRP-004 SmartReader Plus 4 Pressure Data Logger

ACR 01-0120 4 Channel Data Logger: Pressure, Temperature and 2 for optional RH/Temp Probes

Part Number: 01-0115

Be the first to review this product


  • Measure Pressure and Temperature with (2) External Inputs for Temp and RH

  • Self-Contained with 1/4" Quick-Release Pressure Fitting Connection

  • (7) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C

  • 25/second to 8 Hour User-Selectable Sampling Rate

  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery

  • Continuous (FIFO) or Stop When Full Sampling Methods


Requires ACR TrendReader 2 Software and USB Cable Kit

Please allow 5-7 days for this item to ship.

$1,096.00
$1,096.00

SmartReader Plus 4 Pressure Data Logger Specifications

Channels Four (4). Internal Ambient Temperature, Pressure and two (2) optional temperature and Humidity
Accuracy ±0.5% of full scale @25°C (77°F)
Pressure Sensor Multiple Ranges Available:
1. 0 to 10" WC (2.5 kPa) Gauge @ 0.006" Resolution
2. 0 to 5 psi (30 kPa) Gauge @ 0.003 psi (0.02 kPa) Resolution
3. 0 to 30 psi (200 kPa) Absolute @ 0.015 psi (0.1 kPa) Resolution
4. 0 to 30 psi (200 kPa) Gauge @ 0.015 psi (0.1 kPa) Resolution
5. 0 to 100 psi (700 kPa) Absolute @ 0.05 psi (0.34 kPa) Resolution
6. 0 to 100 psi (700 kPa) Gauge @ 0.05 psi (0.34 kPa) Resolution
7. 0 to 150 psi (1000 kPa) Gauge @ 0.05 psi (0.34 kPa) Resolution
Temperature Sensor Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25°C (77°F)
Temperature Accuracy ± 0.2°C, over the range of 0 to 70°C (±0.3°F over the range of 32 to 158°F)
Temperature Range -40 to 70°C (-40 to 158°F)
Temperature Resolution 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C (158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F)
Memory 128KB (87,000 Readings)
External Connector Removable Screw-Type Terminal Strip with Common (-) Connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
Clock Accuracy +/- 2 Seconds per Day
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods Continuous: First-In, First Out (not available with Sample Rates faster than 8 seconds)
Stop when Full: (Fill-then-Stop)
Sampling Rates User Selectable Rates from 25 per second to 1 Reading Every 8 Hours. Battery Pack (#BP-101) or Power Supply (#PS-201) required for sample Rates Faster than 8 second
Resolution 12 Bit (1 part in 4,096)
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regualtions of the FCC
Meets Radiated and Conducted Emission Requirements for the Interfernce Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 Seconds (150 mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine).
Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192-28 curies @ 320 second exposure source to object distance 5"
Battery 3.6 Volt Lithium, 1 Amp-Hour
Battery Life 10 Year Warranty (under normal use), Factory Replaceable
Case Material Noryl Plastic
Mounting Magnetic Backing or Locking Eyelet
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 grams (3.75 Ounces)
Software Compatiblity Windows 8, 7 (32-bit and 64-bit), Vista (32-bit) and XP (SP3)

Customer Reviews

Write Your Own Review

You're reviewing: SRP-004 SmartReader Plus 4 Pressure Data Logger

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Value