OWL 100 Temperature Data Logger
ACR 1 Channel Ambient Temperature Logger
The OWL 100 data logger records temperature in environments that typical
data loggers cannot withstand. The datalogger is also available
in a water-resistant polyurethane enclosure (#OWL-100-POLY)
so it can be used in hostile environments where vibration or
excess moisture is present.
Required with Temperature Data Logger
>> TrendReader 2 Software for OWL (#TR2-LIC)
NOTE: NIST Calibration is available. Large Quantity Discounts Are Available!
Features Specifications
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| OWL Single Channel Temperature Logger (catalog # 01-0250) |
OWL-100-PLASTIC
|
$350.00 |
call |
 |
| OWL Single Channel Temperature Logger - Water Resistant (catalog # 01-0050) |
OWL-100-POLY
|
$450.00 |
call |
 |
| Software Kit - 1 Required |
| TrendReader 2 Software with LIC-101, Manual and Serial Interface Cable for OWL Series (catalog # 01-0227) |
TR2-LIC
|
$230.00 |
call |
 |
| TrendReader 2 Software with Manual and LIC-102 USB Interface Cable (#01-0230) |
TR2-LIC102
|
$240.00 |
call |
 |
| Standard NIST Calibration Service |
| Optional Accessories |
| ACR USB optical Interface Cable |
LIC-102
|
$145.00 |
call |
 |
Data Logger Features
- 10 Year Battery Life
- Can Store about 32,000 Readings
- Very Lightweight
- Very Small and Compact
- Great For Transportation of temperature sensitive goods
Data Logger Specifications
| General Specifications |
| Number of Channels |
One (one internal channel for ambient temperature) |
| Size |
60 mm x 48 mm x 19 mm (2.4" x 1.9" x 0.7") |
| Weight (plastic version) |
54 grams (1.9 ounces) |
| Weight (water-resistant version) |
80 grams (2.8 ounces) |
| Case (plastic version) |
Noryl® plastic |
| Case (water-resistant version) |
Polyurethane |
| Battery |
3.6 volt Lithium, 10 year life typical |
| Warranty |
Data Logger: 3 years, Battery: 10 years |
| Resolution |
8-bit (1 part in 256) |
| Mounting |
Magnetic backing or lock eyelet |
| Clock Accuracy |
±2 seconds per day |
| Sampling Methods |
Continuous (First-in, First-out), Stop When Full
(First-in, First-out not available with sample rates faster
than 8 seconds) |
| Operating Limits |
-40 to 70°C (-40 to 158°F) |
| Submergence Rating |
IP67 - 1 m (3.28') in fresh water for 30 minutes (OWL-100
- POLY) |
| PC Requirements |
IBM PC or 100% compatible with at least one free serial
port,
2 MB of RAM memory, and 2 MB of hard disk space |
| Software Requirements |
TrendReader
2 Software and Interface
Kit |
| Communication |
Optical data transfer; data can be transmitted through
glass,
water, or any transparent medium up to 25 mm (1") away |
| Memory Size |
32KB (capable of storing up to 32,767 readings) |
| Sampling Rates |
User selectable rates from 5 per second to once every 12 hours |
| Internal Temperature Sensor |
| Temperature Sensor |
NTC Thermistor |
| Range |
-40 to 70°C (-40 to 158°F) |
| Total Accuracy* |
± 0.5°C @ 25°C (± 0.9°F @ 77°F)
*Can be increased by using narrow range feature (see below) |
| Resolution* |
0.5°C at 25°C (0.9°F @ 77°F); better
than 1°C (1.8°F) between
-25 and 70°C (-13 and 158°F); better than 2.0°C
(3.6°F)
between -40 and -25°C (-40 and -13°F)
*Can be increased by using narrow range feature (see below) |
| Measurement Range |
Over 200 software selectable ranges available (measurement
spans as narrow as 10°C [18°F] and as wide as 110°C [200°F]) |
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|