Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

SmartReader 2 Data Logger

ACR Four Channel Logger: Temperature, Humidity with options for external Temperature and Humidity

ACR SmartReader 2 Temperature and Relative Humidity Data LoggerThe SmartReader 2 data logger has a built-in temperature sensor, a plug-in relative humidity sensor and is equipped with two extra channels to connect either ACR’s temperature/RH probe or thermistor probes. The RH sensor is field replaceable so you can always be assured of continuous recording. The SmartReader 2 is excellent for monitoring “air quality” conditions.

Required with Temperature Data Logger
>> TrendReader 2 Software

Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)

NOTE: NIST Calibration is available.
Large Quantity Discounts Are Available!

Features   Specifications

Description Part Number Qty 1-9 Qty 10+  
SmartReader 2 4-channels: temperature, RH and optional external temp and RH probes SR-002
$499.00 call
Software Kit - 1 Required
TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series TR2-RS232
$230.00 call
TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series TR2-USB
$240.00 call
TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers TR2-Standard
$130.00 call
External RH/Temp Probe
Remote relative humidity/temperature probe, range 10 to 90% RH, -20° to 40°C (-4° to 104°F) EH-020A
$239.00 $189.00
External Temperature Thermistor Probes
Low Temperature Penetration Probe, stainless steel, 3 1/2" probe w/handle. Thermistor type. Range: -60° to 55°C (-75° to 130°F). Length: 10' (3 meters) ET-004
$168.00 $133.00
Low Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: -60° to 55° (-75° to 130°F). Length: 20' (6 meters) ET-004-GP
$87.00 $69.00
General Purpose Temperature Probe, stainless Steel, 1 X 3/16" probe. Thermistor type. Range: -35° to 95°C (-30° to 200°F). Length: 20' (6 meters) ET-016
$87.00 call
Waterproof Temperature Probe, Stainless Steel, 1 X 3/16" probe. Thermistor type. Range: -40° to 105°C (-40° to 221°F). Length: 20' (6 meters) 35-0035
$119.00 $94.00
Stainless Steel, 1 X 3/16" probe. Thermistor type. Range: 10° to 170°C (50° to 335°F). Length: 20' (6 meters) ET-081
$87.00 $69.00
Oven Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: 70° to 255°C (155° to 490°F). Length: 20' (6 meters) ET-086
$87.00 $69.00
Skin Surface Temperature Probe, stainless steel, 1/3 X 9/64" probe. Thermistor type. Range: 20° to 40°C (68° to 104°F). Length: 5' (1.5 meters) ET-016-STP
$87.00 $69.00
Pipe Surface Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: -35° to 95°C (-30° to 200°F). Length: 20' (6 meters) ET-016-SMP
$87.00 $69.00
Standard NIST Calibration Service
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-TEMP $49.00Temp:
Standard NIST Temp/RH Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-RH
$96.00
Temp/RH:
Optional Accessories
USB Serial Adapter CABLE-USB232
$39.00 $35.00
ACR RS-232 Serial Interface Cable (Limited Quantity - 2 Available) LIC-101--U--
$125.00
$100.00
call
ACR RS-232 Serial Interface Cable LIC-101
$125.00 call

Temperature and RH Logger Features

  • Can Store about 32,000 Readings
  • 10 Year Battery Life
  • Great For HVAC system testing and balancing

Temperature and RH Logger Specifications

General Specifications
Channels Four (one for the internal temperature sensor and one for the internal RH sensor and the remaining two channels can use either ACR’s temperature/RH probe or thermistor probes
Memory 32 KB (32,767 readings)
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams (3.75 ounces)
Case Material Noryl Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Mounting Magnetic backing or locking eyelet
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95%
Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 8 seconds to once every 5 days
Resolution 8 bit (1 part in 256)
Software Compatiblity Windows 3.1, 95, 98, 2000, ME, NT, XP, Vista (32-bit), Windows 7 (32-bit and 64-bit)
Software Requirements TrendReader 2 software and interface cable
Certifications and Standards

- Certified to CE standard EN50082-1: 1992 (European Generic Immunity) covering ESD, RFI and EFT/B
-Meets CE standards EN55011 Class B: 1991 (European Radiated Emissions) and CISPR Class B: 1991(International Radiated Emissions)

Resistance to X-Rays - Tested for protection against a 160kV dose @ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine)
- Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object
distance 5”

Internal Temperature Sensor
Type Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F)
Accuracy ± 0.2°C, over the range of 0 to 70°C (±0.3°F over the range of 32 to 158°F)
Range -40 to 70°C (-40 to 158°F)
Resolution 0.4°C (0.7°F) at 25°C (77°F); better than 1 °C (1.8°F) between -25°C and 70°C (-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C (-40°F and -13°F)

Internal Humidity Sensor
Type Capacitive thin polymer film
Range 0 to 95% RH (non-condensing)
Acccuracy ± 4% RH from 10 to 90% RH (-20 to 40°C [-4 to 104°F])
Resolution Better than 0.4% RH between 25 and 60% RH @ 25°C (77°F)
Response Time Adequate ventilation increases the response time which is approximately 5 minutes in still air
Environmental Conditions Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, Cl2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response.

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax