SmartReader 3 Data Logger
ACR Four Channel Logger: One channel ambient temperature and three channels for AC current probes
The SmartReader 3 data logger makes easy and accurate recordings of AC
current. You can use this logger with up to three external
current probes for recording three-phase systems or related
equipment simultaneously. The easy-to-use ACR CTs provide
safe current readings by simply clamping around the power leads.
Required with SmartReader 3 Data Logger
>> TrendReader 2 Software
Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Keyspan USB Server
NOTE: NIST Calibration is available. Large Quantity Discounts Are Available!
Features Specifications
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| SmartReader 3 four channel AC current logger (catalog # 01-0026) |
SR-003
|
$680.00 |
call |
 |
| Software Kit - 1 Required |
| TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series (catalog # 01-0225) |
TR2-RS232
|
$230.00 |
call |
 |
| TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series (catalog # 01-0226) |
TR2-USB
|
$240.00 |
call |
 |
| TrendReader 2 Software with LIC-101, Manual and Serial Interface Cable for OWL Series (catalog # 01-0227) |
TR2-LIC
|
$230.00 |
call |
 |
| TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers (catalog # 01-0228) |
TR2-Standard
|
$130.00 |
call |
 |
| AC Current Probes |
| 0 to 250 Amps, 60 Hz, user-selectable (0-5, 0-25, 0-100, 0-250 Amps), AC current clamp-on probe (Limited Quantity - 3 Available) |
A60FL
|
$143.00 $115.00 |
call |
 |
| 0 to 250 Amps, 50 Hz, user-selectable, AC current clamp-on probe (0-5, 0-25, 0-100, 0-250 Amps) (catalog # 35-0006) |
A65FL
|
$143.00 |
$113.00 |
 |
| 0 to 500 Amps, 60 Hz, user-selectable, AC current clamp-on probe (0-5, 0-25, 0-100, 0-250, 0-500 Amps) (catalog # 35-0005) |
A70FL
|
$150.00 |
$119.00 |
 |
| 0 to 500 Amps, 50 Hz, user-selectable, AC current clamp-on probe (0-5, 0-25, 0-100, 0-250, 0-500 Amps) (catalog # 35-0007) |
A75FL
|
$150.00 |
$119.00 |
 |
| AC Current Transformer |
| Extends the measurement range of any ACR current probe up to 50 times (Max 3000 amps) (catalog # 38-0000) |
CT-50-2
|
$415.00 |
$395.00 |
 |
| Standard NIST Calibration Service |
| Optional Accessories |
| Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN |
US-4A
|
$129.00 |
call |
 |
| USB Serial Adapter |
Cable-USB232
|
$39.00 |
$35.00 |
 |
| USB 4-Port Serial Adapter |
USA-49WG
|
$149.00 |
call |
 |
Smart Reader 3 Logger Features
- Monitoring 3-phase current
- Start-up or long term load analysis
- Demand side management (DSM)
- Monitoring mechanical systems
- Electric motor maintenance scheduling
Smart Reader 3 Logger Specifications
| General Specifications |
| Channels |
Four:
- Three for AC current for use with ACR
Current probes
- One internal for ambient temperature
|
| Memory |
32 KB (32,767 readings) |
| Size |
107 x 74 x 22 mm. (4.2” x 2.9” x
0.9”) |
| Weight |
110 grams (3.75 ounces) |
| Case Material |
Noryl Plastic |
| External Connector |
Removable screw-type terminal strip with Common (-) connection |
| Mounting |
Magnetic backing or locking eyelet |
| Operating Limits |
-40°C to 70°C (-40°F to 158°F)
and 0 to 95%
Relative Humidity (non-condensing) |
| Clock Accuracy |
±2 seconds per day |
| Battery |
3.6 volt Lithium, 1 Amp-Hour |
| Battery Life |
10 year warranty (under normal use), factory
replaceable |
| Power Consumption |
5 to 10 microamps (continuous) |
| Sampling Methods |
1. Continuous (First-in, First-out)
2. Stop when full (Fill-then-stop) |
| Sampling Rates |
User selectable rates from 8 seconds to
once every 5 days |
| Resolution |
8 bit (1 part in 256) |
| PC Requirements |
IBM PC or 100% compatible running Windows
3.1,
’95, ’98, 2000, Me, NT or XP with at least
2 MB RAM,
2 MB of hard drive disk space and one free serial port |
| Software Requirements |
TrendReader
2 software and interface cable |
| Certifications and Standards |
- Certified to CE standard EN50082-1: 1992 (European
Generic Immunity) covering ESD, RFI and EFT/B
-Meets CE standards EN55011 Class B: 1991 (European Radiated
Emissions) and CISPR Class B: 1991(International Radiated
Emissions)
|
| Resistance to X-Rays |
- Tested for protection against a 160kV dose
@ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times
that of an airport x-ray machine)
- Tested for protection
against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object distance 5” |
| Logger Accuracy |
± 4% of full scale above 10% of range |
| Internal Temperature Sensor |
| Type |
Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F) |
| Accuracy |
± 0.2°C, over the range of 0 to
70°C
(±0.3°F over the
range of 32 to 158°F) |
| Range |
-40 to 70°C (-40 to 158°F) |
| Resolution |
0.4°C (0.7°F) at 25°C (77°F); better than
1 °C
(1.8°F) between -25°C and 70°C
(-13°F and 158°F);
better than 2.0°C (3.6°F) between -40°C
and -25°C (-40°F and -13°F) |
| Current Probes |
| Part Number |
Range |
| A60FL (60 Hz) |
5, 25, 100, 250 Amps |
| A65FL (50 Hz) |
5, 25, 100, 250 Amps |
| A70FL (60 Hz) |
10, 50, 250, 500 Amps |
| A75FL (50 Hz) |
10, 50, 250, 500 Amps |
| Current Channels Accuracy: ±3.5%
of full scale (above the lowest 10% of range) |
| Current Transformer |
| Part Number |
Range |
| CT-50-2 |
Up to 3000 Amps |
| The CT-50-2 extends the AC current sensing range of an
ACR Current Probe by 50 times. 3000 amps maximum continuous
duty. Must be clamped around an A60, A65, A70, or A75FL
Current Probe. |
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|