Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

SmartReader Plus 10 Data Logger

ACR Four Channel Data Logger: One Internal Thermistor and Three External Channels for RTD Probes

ACR SmartReader Plus 10 Data Logger: 4 Channels - Internal Thermistor and 3 External Channels for RTD ProbesThe SmartReader Plus 10 is a powerful and accurate RTD temperature logger designed for easy monitoring and recording of temperature. Any RTD probe or sensor with a TCR of 0.00385 can be used with this logger.

Required with SmartReader Plus 10 Data Logger
>> TrendReader 2 Software

Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Keyspan USB Server
>> Read the Networking and Remote Communications Guide

NOTE: Large Quantity Discounts Are Available!

Features   Specifications   Fast Sample Rates

Description Part Number Qty 1-9 Qty 10+  
SmartReader Plus 10 128KB, 4-channels: one temp and 3 RTD's (catalog # 01-0132) SRP-010-128K
$1,050.00 call
Software Kit - 1 Required
TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series (catalog # 01-0225) TR2-RS232
$230.00 call
TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series (catalog # 01-0226) TR2-USB
$240.00 call
TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers (catalog # 01-0228) TR2-Standard
$130.00 call
Optional Accessories
Fast Sampling Battery Pack (catalog # 01-0078) BP-101
$54.00 call
Network/Fast Sampling Power Supply - 120V - North American Version (catalog # 01-0165) PS-201-NA
$66.00 $53.00
Network/Fast Sampling Power Supply - 220V - European Version (catalog # 01-0164) PS-201-EU
$76.00 $60.00
Extra RS-232 Interface Cable for SmartReader, SmartReader Plus and Nautilus loggers (catalog # 01-0068) IC-101
$119.00 call
Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN US-4A
$129.00 call
USB Serial Adapter Cable-USB232
$39.00 $35.00
USB 4-Port Serial Adapter USA-49WG
$149.00 call

SmartReader Plus 10 Logger Features

  • Data Storage Capacity of 87,000 Readings
  • 4 Channels
  • 10 Year Battery Life

SmartReader Plus 10 Logger Specifications

General Specifications
Channels Four (one internal thermistor channel for ambient temperature and three external channels for use with RTD* temperature probes)
*Any RTD with a Temperature Coefficient of Resistance (TCR) of 0.00385 can be used
Memory Size 128 K (87,000 readings)
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams (3.75 ounces)
Case Material Noryl Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95%
Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out – not available with
sample rates faster than 8 seconds)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds)
Resolution 12 bit (1 part in 4,096)
Mounting Magnetic backing or locking eyelet
PC Requirements IBM PC or 100% compatible running MS Windows 3.1,
’95, ’98, 2000, Me, NT, XP or Vista 32-bit with at least 2 MB RAM,
2 MB of hard drive disk space and one free serial port
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal
Regulations of the Federal Communications Commission
(FCC). Meets radiated and conducted emission require
ments for the Interference Causing Equipment Standard f
or Digital Apparatus of Industry Canada (ICES-003).
IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity,
EFT/Burst and Radiated Emissions respectively for the
Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times
that of an airport x-ray machine). Tested for protection
against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object
distance 5”

RTD Channels
The following specifications are for:
4-Wire Platinum 100 Ohm @ 0° C & TCR = 0.00385
4-Wire Platinum 1000 Ohm @ 0° C & TCR = 0.00385
Temperature
Range* -230 to 300°C (-382 to 572°F)
Accuracy ± 0.3°C (± 0.54°F) + resolution or
± 0.06% full scale (of logger)
Resolution ± 0.14°C (± 0.25°F)
Resistance (100 Ohm)
Range 5 to 210 Ohm
Accuracy ± 0.13 Ohm, ± 0.06 % full scale
Resolution ± 0.05 Ohm
Resistance (1000 Ohm)
Range 50 to 2100 Ohm
Accuracy ± 1.3 Ohm, ± 0.06% full scale
Resolution ± 0.5 Ohm
*Temperature compensated by internal temperature sensor for the range of -20 to 80°C (-4 to 176°F)

Fast Sampling with Battery Pack or External 120 Volt Power Supply
For sampling rates faster than once every 8 seconds, the Smart Reader Plus data loggers require the use of an external 120 volt power supply (#PS-201) or fast sampling battery pack (#BP-101).

The fast sampling battery pack has replaceable "AAA" batteries and 8" (20cm) cable attached, with a male stereo jack on the end. The stereo jack is plugged into the communication port on the Smart Reader Plus data logger.

The 120 Volt Power Supply is required when network length is greater than 50' , more than 3 loggers are on the network, or for sampling rates greater than 8 seconds on the SmartReader Plus Loggers.

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax