Power Quality Data Loggers
AEMC Power Quality Data Logger Models PQL 100 and PQL 120
The AEMC Power Quality Loggers are single-phase
data loggers designed to measure and log a complete
suite of electrical and power quality parameters. Designed
for North American commercial, industrial and residential applications,
the Power Quality Loggers can be plugged into standard
USA 120 V AC receptacles.
Included with each Power Quality Logger
1. DataView Software and User Manual
Features Specifications
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| AEMC Power Quality Logger with 6ft extension cable |
PQL120
|
$895.00 |
call |
 |
Power Quality Logger Features
Measures and Stores Electrical Parameters: V, A, Hz and more
- Measures and Stores Power Parameters: W, VA, VAR, Demand, Peak Demand and more
- Measures and Stores Power Quality Parameters: Harmonics, THD (RMS and fundamental), K-Factor
and more
- Automatically captures worst-case Surge, Sag and THD waveforms
- High accuracy and resolution: 128 samples/cycle, 16 bit resolution
- Records up to 12 data channels
- Battery backup data integrity during power outages for up to one year (configuration in nonvolatile
memory)
- Includes DataView® Lite software for data storage, analysis and report generation
Power Quality Logger Specifications
| Measurements |
True RMS measurement. 128 samples are simultaneously taken for voltage
and current channel. |
| Voltage |
| Range |
0 to 140V |
| Resolution |
0.1V |
| Accuracy |
±(0.3% of Reading + 0.3V) |
| Current |
| Range |
0 to 15A (70A peak maximum) |
| Resolution |
0.01A |
| Accuracy |
±(0.5% of Reading + 0.03A) @ 0.75A to 15A ±0.30A @ < 0.75A |
| Frequency (Hz) |
| Range |
45 to 65Hz |
| Resolution |
0.01Hz |
| Accuracy |
0.1Hz |
| Harmonics |
| Range |
45 to 65Hz |
| Resolution |
0.1V for Voltage & 0.1A for Current |
| Power– Watt/VA/VAR |
| Range |
0 to 2,100 Watt, VA or Var |
| Resolution |
0.1W, 0.1VA, 0.1Var |
| Accuracy |
±(2.0% of Reading + 4x), where x is Watt or VA or Var |
| Power & Power Factor |
| Resolution |
0.01 |
| Accuracy |
±0.03% @ PF/DPF = 1 |
| Programmable Parameters |
| |
V,A,Hz,Odd & Even Harmonics (V & A), W, VA, Var, THD (V & A), PF, DF, K-Factor |
| Demand |
VA, W (10/15/30 minutes or user-definable) |
| Peak Demand |
Over demand period |
| Voltage Sag |
User-definable magnitude |
| Voltage Surge |
User-definable magnitude |
| Input |
| Input Channels |
1 Voltage/1 Current |
| Sample Rate |
128 per cycle per channel |
| Recording |
| Storage Rate |
125ms to 7 days |
| Recording Session Length |
15 minutes to 8 weeks (user programmable) |
| Total Memory |
1MB |
| Date and Time |
MM/DD/YY hh/mm/ss.sss |
| Surge and sag and THD Waveform Storage |
20 worst-case |
| |
|
| General Specifications |
| Operating Range |
14° to 122°F (-10° to 50°C), 0% to 85%RH @ 95°F
(35°C), non-condensing |
| Storage Temperature |
-4 to 140°F (-20° to 60°C) |
| Material |
UL94V-O ABS plastic |
| Dimensions |
5.91 x 3.15 x 2.36" (150 x 80 x 60mm) |
| Weight |
1lb 7oz (650g) including the batteries |
| Safety Rating |
IEC 1010-1, 150V Cat. III, Pollution Degree 2 |