Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

DC Voltage Simple Logger® II

AEMC 2-Channel Logger Measuring and Recording DC Voltage

The DC Voltage Simple Logger II has 2 independent channels measuring and recording dc voltage using an external probe. The dc voltage logger features non-volatile memory, storage of 240,000 samples, 3 user selectable storage modes and includes software.

>> Monitor and Record Using 2 External DC Voltage Probes
>> 2 Independent Input Channels
>> Store up to 240,000 Samples/Readings in Non-Volatile Memory
>> 3 User Selectable Storage Modes
>> 5 LED Indicators Quickly and Clearly Display Logger Status
>> Includes DataView Software for Real-Time Waveform Display, Analysis and Report Generation

NOTE: Large Quantity Discounts Are Available!

  • Specifications
  • Applications
  • Purchase

DC Voltage Simple Logger® Specifications

Number of Channels 2 Channels
Input Connection Detachable Terminal Strip
Measurement Range ±100mV/1V/10VDC
(Selectable through DataView Software)
Resolution 0.1 mV - 1 mV - 10mV
Accuracy
(DC and 50/60Hz)
0 to 1 mV: unspecified
10 to 100 mV: ±(0.5% of Reading + 1 mV)
0 to 10 mV: unspecified
10 to 1000 mV: ±(0.5% of Reading + 1 mV)
0 to 100mV: unspecified
100 mV to 10.00 V: ±(0.5% of Reading + 10 mV)
Sample Rate 8 Samples Taken at Storage Interval
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM™)
Storage Rate Programmable from 125ms to 1 Day
Recording Length 15 Minutes to 8 Weeks
Programmable Using DataView Software
Data Storage Capacity 240,000 Readings/Measurements
(Stored in Non-Volatile Memory, Retained If Battery is Low or Removed)
Communication USB 2.0 Optically Isolated
Power Source (2) 1.5 Volt AA-cell Alkaline Batteries
Battery Life 100 Hours to > 45 Days
(Dependent on Sample Rate and Recording Length)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Dimensions 5.43" x 2.75" x 1.28" (138mm x 70mm x 32mm)
Weight 6.4 oz (181 grams)

DC Voltage Simple Logger® Applications

  • Circuit Design Troubleshooting
  • Sensor Monitoring
  • Battery Testing
  • Power Supply Profiling
AEMC DC Voltage Simple Logger II AEMC DC Voltage Simple Logger II
Includes:
>> DataView Software
>> (2) AA Alkaline Batteries
Price: $339.00
Part #: L432

Optional Accessories
AA Lithium Batteries AA Lithium Batteries
>> 4 Pack
QuantityPrice Each
1 - 4$19.00
5+ $15.00
Part #: HWSB-LI


 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax