Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

Advanced Pulse WattNode®

Continental Control Systems AC Watt-Hour Transducer with Pulse Output

HOBO U12 Temperature Data LoggerThe WattNode® is a true RMS AC watt-hour transducer with pulse output (solid state relay closure) proportional to kWH consumed. The WattNode® features easy installation, LEDs indicating power, negative power and advanced diagnostics on a per-phase basis.

Required
>> Voltage Input Leadset (#A-WNB-LEADSET)
>> Current Transformer (Minimum 1)

Features   Specifications   Applications

WattNode 208/240 VAC Wye kWh Transducer WattNode 208/240 VAC Wye kWh Transducer
>> Line to Neutral: 120 Volts AC
>> Line to Line: 208-240 Volts AC
>> Phases: 3
>> Wires: 4
Price: $198.00
Part #: WNB-3Y-208-P

WattNode 3 Phase, 230-400 Volts AC, 4 Wires WattNode 3 Phase, 230-400 Volts AC, 4 Wires
>> Line to Neutral: 230 Volts AC
>> Line to Line: 400 Volts AC
>> Phases: 3
>> Wires: 4
Price: $230.00
Part #: WNB-3Y-400-P

WattNode 3 Phase, 277-480 Volts AC, 4 Wires WattNode 3 Phase, 277-480 Volts AC, 4 Wires
>> Line to Neutral: 277 Volts AC
>> Line to Line: 480 Volts AC
>> Phases: 3
>> Wires: 4
Price: $230.00
Part #: WNB-3Y-480-P

WattNode 3 Phase, 347-600 Volts AC, 4 Wires WattNode 3 Phase, 347-600 Volts AC, 4 Wires
>> Line to Neutral: 347 Volts AC
>> Line to Line: 600 Volts AC
>> Phases: 3
>> Wires: 4
Price: $243.00
Part #: WNB-3Y-600-P

WattNode 208/240 VAC 3-Phase Delta kWh Transducer WattNode 208/240 VAC 3-Phase Delta kWh Transducer
>> Line to Neutral: 120 Volts AC
>> Line to Line: 208-240 Volts AC
>> Phases: 3
>> Wires: 3
Price: $230.00
Part #: WNB-3D-240-P

WattNode, 3 Phase, 230-400 Volts AC, 3 Wires WattNode, 3 Phase, 230-400 Volts AC, 3 Wires
>> Line to Neutral: 120 Volts AC
>> Line to Line: 400 Volts AC
>> Phases: 3
>> Wires: 4
Price: $243.00
Part #: WNB-3D-400-P

WattNode 480 VAC 3-Phase Delta kWh Transducer WattNode 480 VAC 3-Phase Delta kWh Transducer
>> OPEN BOX: 1 Available
>> Line to Neutral: 277 Volts AC
>> Line to Line: 480 Volts AC
>> Phases: 3
>> Wires: 3
Price: $244.00 $185.00
Part #: WNB-3D-480-P--U--

WattNode 480 VAC 3-Phase Delta kWh Transducer WattNode 480 VAC 3-Phase Delta kWh Transducer
>> Line to Neutral: 277 Volts AC
>> Line to Line: 480 Volts AC
>> Phases: 3
>> Wires: 3
Price: $243.00
Part #: WNB-3D-480-P

Voltage Input Leadset - Required
Voltage Input Lead Set and Cables Voltage Input Lead Set and Cables
>> Connects WattNode to Voltage Terminals in Circuit Breaker Panel
>> Prevents Mis-Wiring to KWH Transducer
>> 5 Ft Cable Length
>> Includes (5) Alligator Clips with Matching Cable (Black, Blue, Green, Red and White)
Price: $70.00
Part #: A-WNB-LEADSET

Split Core Current Transformers - 1 Required
Split Core Current Transformer w/ 0.75" ID Split Core Current Transformer w/ 0.75" ID
>> Inside Diameter: 0.75"
>> Output: 0.333 AC Volts
>> 8 ft Twisted Pair Lead
>> available Rated Amps: 5, 10, 30, 50, 70, 100, 150, 200
Price: $42.00
Part #: CTS-0750
Rated Amps:

Split Core Current Transformer w/ 1.25" ID Split Core Current Transformer w/ 1.25" ID
>> Inside Diameter: 1.25"
>> Output: 0.333 AC Volts
>> 8 ft Twisted Pair Lead
>> Available Rated Amps: 50, 70, 100, 150, 200, 250, 300, 400, 600
Price: $46.00
Part #: CTS-1250
Rated Amps:

Split Core Current Transformer w/ 2.00" ID Split Core Current Transformer w/ 2.00" ID
>> Inside Diameter: 2.00"
>> Output: 0.333 AC Volts
>> 8 ft Twisted Pair Lead
>> Available Rated Amps: 100, 200, 300, 400, 600, 800, 1000, 1200, 1500
Price: $66.00
Part #: CTS-2000
Rated Amps:

Advanced Pulse WattNode® Features

  • True RMS AC Watt-Hour Transducer with Pulse Output
  • Advanced Pulse Output Separate Pulse Channels for Positive and Negative Power
  • Use of Safe CTs with Output Limited to 1 Volt
  • No External Power Supply Required, Line Powered
  • Digital Signal Processing Accurate kWH Measurement over a Wide Harmonic Range
  • Easy to Install and Remove Detachable Terminal Blocks

Advanced Pulse WattNode® Specifications

Measurement Configurations Single Phase: 2-Wire or 3-Wire
Three Phase: 3-Wire or 4-Wire
Electrical Line Powered
Operating Voltage Range: +15%, -20% of Nominal
Power Line Frequency: 50/60 Hz
CT Input: 0.333 VAC
Pulse Output Optoisolated, solid state relay closures handle up to Max. 60 VDC & to 5mA
Standard: 4.00 Hz Bidirectional Output
Accuracy Normal Operation: Line Voltage: 80% to 115% of Nominal
Power Factor: 1.0
Frequency: 48 to 62 Hz
Ambient Temperature: 25°C
Current: 5% to 100% of Rated Current
Accuracy: ±0.5% of Reading
Operating Range Temperature: -30C to 55C (-22F to 131F)
Humidity: 5 to 90% RH
Enclosure High Impact. UL Rated, ABS Plastic
Connectors UL, CSA Recognized, Detachable, Screw Terminals (14 AWG), 600 Volts
Battery Life Approximately 4 Years
Battery Lithium 2/3A
Dimensions 80.4mm x 140.22mm x 30.2mm (3.3" x 5.6" x 1.25")

Advanced Pulse WattNode® Applications

  • Sub-Metering
  • Energy Management
  • Performance Contract Applications

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax