MicroLog External Input Sensors
Below are the specifications for the optional external sensors that are
available for the MicroLog external
input channels available on the EC600, EC650, EC700 and EC750 Data Loggers. |
 |
DT132 External Temperature Sensor with Probe
This MicroLog sensor takes external
temperature measurements in a wider range than the
internal temperature sensor. With a faster response
time than the internal sensor, it enables measuring
materials that cannot be measured with the internal
sensor. Download the
External
Temperature Sensor PDF file.
| Range |
-50 to 100°C (-58 to 212 °F) |
| Resolution |
Better than 2°C |
| Accuracy |
±2% of reading |
| Probe Tip |
100mm |
| Cable Length |
2.5 Meters |
| Probe OD |
3.2mm |
| Maximum Temperature |
150°C |
External PT100 Temperature Sensor
| Range |
-10°C to 10°C (DT252 Adapter Required)
-100°C to 120°C (DT253 Adapter Required) |
| Resolution |
0.1°C / 1.1°C |
| Accuracy |
±0.25°C / ±1°C |
| Connector |
Screw Terminal |
| Requirements |
External Adapter DT252 or DT253. |
DT093 External Temperature Sensor with Probe
| Range |
-50 to 100°C (-58 to 212 °F) |
| Resolution |
Better than 2°C |
| Accuracy |
±2% of Reading |
| Probe Tip |
100mm |
| Cable Length |
8 Meters |
| Probe OD |
3.2mm |
| Maximum Temperature |
100°C |
Light Sensor
| Range |
0-5000 lx |
| Resolution |
25 lx |
| Accuracy |
25% of reading |
pH Sensor
| Range |
1 to 14pH |
| Resolution |
0.116pH |
| Accuracy |
2% of reading |
| Calibration: |
Single point, done with a small trimmer on the
sensor. |
0-10 Voltage Sensor
A general sensor that will measure
any device or transmitter that produces a linear
analog 0-10V output. The voltage can easily be
converted to the correct measured units with the
help of the MicroLab program. Download the
0-10 Volt Sensor PDF file.
| Range |
0-10V |
| Accuracy |
±3% before calibration |
| Input Impedance |
3M |
| Calibration |
Two point calibration |
| OV Protection |
+30V |
| Resolution |
0.05V |
0 - 20 mAmp External Current Sensor
This MicroLog external sensor can sample
any device or transmitter, producing a linear current
between 0-20 mA. The 0-20 mA can be converted to
the correct measured units by using MicroLab's calibration
option. Download the 0-20
mAmp External Sensor PDF file.
| Range |
0-20mA |
| Resolution |
±0.1mA |
| Accuracy |
±3% before calibration |
| Calibration |
Two point calibration |
| OC Protection |
55mA |
External Contact Adapter
This MicroLog sensor monitors Reed
Relay contacts and switch status (open/closed), to
identify the correlation between phenomena such
as temperature change and door status. Download
the
External Contact Adapter PDF file.
| Range |
Open/Close |
| Connector |
Screw terminal |
| Cable Length |
2.5m |
| Internal Pull-Up Resistor |
No need for external power source |