Specifications for the DaqPro 8-Channel Data Logger

General Specifications
Communication USB 1.1 compliant
Sampling Capacity 512KB
Analog Sampling Rate Variable, 1 sample/hour to 4,000 samples/sec, 1 channel**
Analog Sampling Resolution 16 bits
Operating Temperature 0 to 50°C
Case Plastic ABS Box
Dimensions 182x100x28 mm
Weight 450g
Man Machine Interface Full keyboard operation - enables manual programming of the logger
Graphic LCD 64x128 pixels
Power Supply Internal rechargeable 7.2V NiCa battery
Built in battery charger
External 9V to 12V DC input
Battery life: 40 hours between charges
Standards Compliance: CE, FCC
Note: ** The Number of Sensors in Use limits the Maximum Sampling Rate. Refer to Section 1.2.10 of the User Manual for Details.
 Input Specifications
Channels 8 differential inputs
Selectable type for each input 0-24mA, 0-50mV, 0-10V, NTC, PT-100, Thermocouple, Pulse and frequency (Input 1 only)
 
0-24mA Inputs
Range 0-24mA
Resolution 0.47µA
Accuracy ±0.5% FS
Loop Impedance 195Ω
 
0-50mV Inputs
Range 0-50mV
Resolution 3µV
Accuracy ±0.5% FS
 
0-10V Inputs
Range 0-10V
Resolution 200µV
Accuracy ±0.5% FS
Input Impedance 125kΩ
 
Temperature NTC
NTC 10/100KΩ resistor
Range -25 to 150°C
Resolution 0.05°C
Accuracy ±0.5% FS
 
Temperature PT-100
Range -200 to 400°C
Resolution 0.1°C(7mΩ)
Accuracy ±0.5% FS
Note: The DaqPRO offers up to 8 PT-100 2 wire channels or 4 PT-100 3 wire channels
 
Temperature Thermocouple Type J
Range: -200 to 1200°C
Resolution 0.1°C(1µV)
Accuracy ±0.5% FS
Cold Junction Compensation Error ±0.5°C
 
Temperature Thermocouple Type K
Range -250 to 1200°C
Resolution 0.1°C(1µV)
Accuracy ±0.5% FS
Cold Junction Compensation Error ±0.5°C
 
Temperature Thermocouple Type T
Range -200 to 400°C
Resolution 0.1°C(1µV)
Accuracy ±0.5% FS
Cold Junction Compensation Error ±0.5°C
 
Internal Temperature
Range -25 to 70°C
Resolution 0.1°C(1µV)
Accuracy ±0.5% FS
 
Pulse Counter (Input 1 only)
Input type Optocoupler input
Range 0-65,000
Input Signal 0-5V
Input Impedance 470Ω
Bandwidth 0-50hz
 
Frequency Meter (Input 1 only)
Input type Optocoupler input
Range 20-4,000Hz
Input Signal 0-5V
Input Impedance 470Ω
 
A to D Specifications
Noise 30µV rms
Internal Linearity Error ±0.08% of FSR
Offset Error 0.1%
 
Open Collector Output (Output B)
Maximum Current Sink 50mA (fuse protected)
Input Impedance 50Ω