Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

GL800 Midi Data Logger

Graphtec GL800 Midi Data Logger

GL800 20-Channel Midi Data Logger accepts temperature,voltage, humidity, pulse and logic signals The GL800 midi data logger accepts voltage, temperature, humidity, pulse and logic signals. The sensors are connected via rear mounted screw terminals. With its channel-to-channel isolation, wiring errors or overloaded channels will not affect neighbouring channels, due to its channel-to-channel isolation. Its built-in 12.0MB non-volatile memory retains data even if the power supply is interrupted. The included software provides real-time waveform monitoring, data upload and data export to spreadsheets.

Included With Each Midi Logger
>> User Manual
>> Software

Optional Accessories Available
>> Humidity Sensor (#B-530)
>> 6 Hour Battery Pack (#B-517)
>> DC Power Cable (#B-514)

Features   Specifications   User Manual & Application Notes

NOTE: Large Quantity Discounts available!

Description Part Number Qty 1-9 Qty 10+  
GL800 Midi Data Logger GL800
$1,995.00 call
Optional RTD Sensors
Tip Sensitive RTD ± 0.5% at 0°C RTD-IND-S54PA
$69.00 $65.00
Tip Sensitive RTD ± 0.1% at 0°C (Limited Quantity - 2 Available) RTD-IND-S854PD--U--
$85.00
$68.00
call
Tip Sensitive RTD ± 0.1% at 0°C RTD-IND-S854PD
$85.00 $79.00
Optional Thermocouples
Welded Tip Teflon Thermocouple w/ 72" Bare Wire Leads Welded Tip Teflon Thermocouple w/ 72" Bare Wire Leads
>> Operating Range: -75°C to 250°C
>> Leads: 72" Teflon Insulated Twisted Pair Bare Wire Leads
>> Available in Type J, K, T and N
QuantityPrice Each
1 - 9$10.00
10 - 25$9.00
26+ $8.00
TC Type:

Welded Tip Teflon Thermocouple w/ 180" Bare Wire Leads Welded Tip Teflon Thermocouple w/ 180" Bare Wire Leads
>> Operating Range: -75°C to 250°C
>> Leads: 180" Teflon Insulated Twisted Pair Bare Wire Leads
>> Available in Type J, K, T and N
QuantityPrice Each
1 - 9$19.00
10 - 25$18.00
26+ $16.00
TC Type:

Optional Accessories
Extension Terminal Base Set B-537
$300.00 call
20-Channel Extension Terminal Set B-538
$600.00 call
Graphtec Battery Pack B-517
$120.00 call
DC Power cable, 2 meters, bare ends, for direct connection to DC power source B-514
$50.00 call
Cable: 4x logic inputs, 4x alarm outputs, 2 meters B-513
$80.00 call
Graphtec Humidity Sensor B-530
$400.00 call
Yellow Xtreme Protective Case (11.93" x 9.02" x 4.02") T6000.2
$63.00 call
Black Xtreme Protective Case (11.93" x 9.02" x 4.02") T6000.3
$63.00 call
Cole Parmer 12" Length Cable Adapter, Type K 93786-02
$15.00 call

Midi Logger Features

  • Accepts Voltage (20mv to 50V FS), Thermocouples, RTDs, 4-20mA and Humidity inputs
  • Expandable to 200 Channels
  • 5.7" Color TFT LCD Display
  • Ethernet and USB 2.0 Computer Interfaces
  • Network Ready
  • USB Flash Memory Slot for Data Archival
  • Includes Windows software for setup, control, data transfer, data conversion to ASCII and Excel formats, and on-screen data review with cursors

GL800 Logger Specifications

Number of Channels 20 Channels (Expandable to 200)
Input Method Scanning
Input Types Voltage, Current, Thermocouple, RTD, Humidity
Voltage Input Ranges ±20mV to ±50 V, ±1 to 5V (4 to 20 mA)
Voltage Measurement Ranges 20mV,50mV,100mV,200mV,500mV, 1V,2V,5V,10V,20V,50V, 1-5 Volts FS
Thermocouple Input Types K, J, E, T, R, S, B, N, W
RTD Input Types PT100 and JPT100
Internal Memory Capacity 12.0 MB
Sampling Interval 100 ms to 1 Hour
Alarm Function Analog, Logic or Pulse
Operating Environment Temperature: 0 to 45°C
Humidity: 5 to 85% RH
Certifications CE, RoHS, China RoHS
Software Compatibility Windows 2000/XP
Power Supply 100 to 240 VAC, 50/60 Hz AC Adapter (Included)
DC Input (8.5 to 24VDC), Battery Pack (Optional)
Dimensions 232mm x 152mm x 50mm
Weight 990g (Battery and AC Adapter excluded)

Humidity Sensor Specifications (#B-530)

Measurement Range Temperature: -25 to 80C
Humidity: 0-100% RH
RH Accuracy 3%RH (5 to 98%RH at 25C)
Response Time 15 seconds (90% Rtesponse When Membrane Filter Installed)
Output 0 to 1 Volt DC
Power Source 5 to 16 Volts DC
Power Consumption Approx. 4 mA
Dimensions 14mm x 80mm
Cable Length 3 Meters

Battery Pack Specifications (#B-517)

Capacity 7.2 Volts/2200 mAh
Battery Type Lithium Scondary Battery
Running Time Up to 2 Packs can be Mounted
When LCD is On:
Battery Pack x 1 (Brightness MAX): Approx. 2.5 Hours
Battery Pack x 1 (Brightness MIN): Approx. 3.0 Hours
Battery Pack x 2 (Brightness MAX): Approx. 5.0 Hours
Battery Pack x 2 (Brightness MIN): Approx. 6.0 Hours
When LCD is Off:
Battery Pack x 1: Approx. 4.5 Hours
Battery Pack x 2: Approx. 9.0 Hours
Note: When Capturing to Internal Memory at 1 s, sampling, 20 channel terminals, using new battery packs at 25C Environment.
Note: The Running Time Depends on the Operating Environment.
Charging Method Mount in the Main Unit
Time Required for Charging Battery Pack x 1: Approx. 4.0 Hours
Battery Pack x 2: Approx. 8.0 Hours
Switchover in the Case of a Power Failure Because the Battery is Used Together with the AC Adapter, the Power Supply will be Switched Automatically to the Battery in the Event of a Power Failure.
Note: The AC Adapter is the Primary Power Source.
Operating Environment 15°C to 40°C
Other Functions >> When Battery is Running Low, File is Closed Automatically
(When Captured to Internal Memory or USB Memory)
>> Remaining Amount Indicator

GL800 User Manual (.pdf 9.78 MB)
How to Connect a 4-20mA Sensor (.pdf 400K)

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax