GL1100 Hard Disk Data Logger
Graphtec Logger with 40 GB Hard Drive and Sampling Rate up to 40 MS/s per Channel
The GL1100 Hard Disk Logger provides high speed and simultaneous sampling of voltage, voltage/temperature, strain and frequency amplifiers. The data logger features high speed sampling up to 40 MS/Second per Channel, Web and FTP Server, Internal 40GB hard drive, Built-in Ethernet and USB Interfaces, PCM drive slot, Internal 2 MS memory and accepts 4 or 8 GL11 Series preamps.
2 Versions of GL1100 Logger Available
>> 8-Channel (#GL1100-8)
>> 16-Channel (#GL1100-16)
PreAmps (Amplifiers) Available
>> 2-Channel Voltage Module (#GL11-HSV)
>> 2-Channel Multi-Input Module (#GL11-M)
>> 2-Channel DC Strain Module (#GL11-DCB)
Included With Each Logger
>> User Manual and Software
Features Specifications Amplifiers
NOTE: Large Quantity Discounts available!
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| Graphtec 40 MHz 8-Channel Hard Disk Data Logger |
GL1100-8
|
$3,700.00 |
call |
 |
| Graphtec 40 MHz 16-Channel Hard Disk Data Logger |
GL1100-16
|
$4,700.00 |
call |
 |
| Plug-in Amplifiers - 1 Required |
| Graphtec Voltage Preamp 2 Channel Module |
GL11-HSV
|
$1,000.00 |
call |
 |
| Graphtec Multi-Input Preamp 2 Channel Module |
GL11-M
|
$800.00 |
call |
 |
| Graphtec DC Strain Preamp 2 Channel Module |
GL11-DCB
|
$1,000.00 |
call |
 |
| Optional Accessories |
| Graphtec 8.4" TFT Color Monitor |
B-534
|
$1,400.00 |
call |
 |
| 100mm wide Printer, Thermal Array, 25 mm/s Max Chart Speed |
B-535
|
$1,000.00 |
call |
 |
| 12 Volt DC Power Supply Option (10-16 VDC, approximately 150 VA) |
B-505
|
$1,600.00 |
call |
 |
| Extended Monitor Cable Set (1m and 22.5cm) |
B-506
|
$300.00 |
call |
 |
| Cable to connect two GL units together(synch), 1 meter |
B-515
|
$50.00 |
call |
 |
| Graphtec AC Current Clamp: 0 to 1200 AAC |
CM-102
|
$95.00 |
call |
 |
| Graphtec Digital Clamp Meter |
CM-111
|
$795.00 |
call |
 |
| Graphtec Digital Clamp Meter |
CM-108
|
$50.00 |
call |
 |
| Graphtec Temperature Probe, -30C to 200C, (use with Digital Clamp Meter #CM-111) |
RIC-110
|
$75.00 |
call |
 |
| Graphtec Floating Voltage Input Probe |
CM-105
|
$495.00 |
call |
 |
| Graphtec Voltage Fluctation Probe |
CM-106
|
$495.00 |
call |
 |
| Alligator Clip Cable |
RIC-08
|
$50.00 |
call |
 |
| Graphtec IC Clip Cable |
RIC-09
|
$50.00 |
call |
 |
| Graphtec Logic IC Cable |
RIC-07
|
$50.00 |
call |
 |
| Graphtec Logic Probe Set (1 each of RIC-07, RIC-08, RIC-09) |
RIC-10
|
$125.00 |
call |
 |
| Graphtec Isolated Probe, x1/x10 |
RIC-142-US
|
$125.00 |
call |
 |
| Graphtec BNC to BNC 6ft Cable |
RIC-112
|
$35.00 |
call |
 |
| Graphtec BNC to Banana 6ft Cable |
RIC-113
|
$36.00 |
call |
 |
| Graphtec BNC to Alligator Clips 6ft Cable |
RIC-114
|
$27.00 |
call |
 |
Hard Disk Logger Features
- Available in 8 or 16-Channel Input Versions
- Up to 40 MS/s Sampling per Channel
- Allows combined use of Voltage, Voltage/Temp, Strain and Frequency Amplilfiers
- Built-in Web and FTP Server to share and transfer data
- Optional 8.4" Color TFT LCD Display and Printer
- Includes Windows software for setup, control, data transfer, data conversion to ASCII and Excel formats, and on-screen data review with cursors
- Requires at least 1 PreAmplifier Plug-in to Operate
Hard Disk Logger Specifications
| Analog Input |
GL1100-8: 8 Channels (4 Slots)
GL1100-16: 16 Channels (8 Slots) |
| Logic Input |
GL1100-8: 8 Channels
GL1100-16: 16 Channels |
| Internal Memory Storage |
GL1100-8: 2 Mword/channel
GL1100-16: 2 Mword/channel |
| Hard Drive Storage |
40 GB |
| Synchronize Function |
N/A |
| PC Interface |
PCMCIA Slot (Type II), Ethernet LAN or USB |
| Operating Environment |
Temperature: 0 to 40C
Humidity: 30 to 80% RH |
| Rated Power Supply |
GL1100-8: AC Adapter (100V to 240V AC)
GL1100-16: N/A |
| Power Consumption |
GL1100-8: 90 VA Max
GL1100-16: 135 VA Max |
| External Dimensions |
GL1100-8: 11.81" x 8.74" x 2.24"
GL1100-16: 11.81" x 8.74" x 4.48"
Excludes Rubber Boot |
| Weight |
GL1100-8: 2.4kg (includes 4 amplifiers)
GL1100-16: 4.2kg (includes 8 amplifiers)
Optional AC Adapter Excluded |
Hard Disk Logger Amplifiers
2-Channel Voltage Preamp Module
- Floating Ground with Unbalanced Load Input (Independent Channels)
- 200mV to 200 Volt Full-Scale
- 25 ns Sample Interval (40MHz) @ 12-bit Resolution
- Frequency Response: DC to 10 MHz
- Input Filter: 5, 50, 500, 5k, 50k, 500k (Hz)
2-Channel Multi-Input Preamp Module
- Floating Ground with Unbalanced Load Input (Independent Channels)
- Voltage Input: 20 MV to 500V Full-Scale
- Thermocouple Inputs: J, K, T, R, E, B
- 10 us Sample Interval (100kHz) @ 16-Bit Resolution
- Frequency Response: DC to 20 kHz
- Input Filter: 1.5, 5, 10, 30, 50, 500, 5k (Hz)
2-Channel DC Strain Preamp Module
- Floating Ground with Unbalanced Load Input (Independent Channels)
- 1000 to 20,000 x 10-6 Strain Full-Scale
- 10 us Sample Interval (100kHz) @ 16-Bit Resolution
- Frequency Response: DC to 20 kHz
- Input Filter: 1.5, 5, 30, 100, 300, 1k (Hz)
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.