Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

ICP Signal Conditioner Modules

Isolated DC Voltage, 4-20mA or Strain Gauge Input/Output Modules

ICP Signal Conditioner Modules ICP Signal Conditioners are voltage/current input to voltage/current output modules. They have 3000Vdc three-way isolation for input, output and power and they can change the input/output range via internal configuration switches. Modules are available in voltage, current or strain gauge versions.

Each signal conditioner module has an LED display to show whether it is functioning correctly and has two VRs (Zero, Span) to calibrate the input/output range accuracy. The strain gauge module has three VRs (Zero, Span, Exci).

The bandwidth of the signal conditioner modules is typically 3KHz. They are easy to mount on a standard DIN rail and can operate in environments with wide temperature range.

Ordering Information


Specifications

SG-3071 Isolated DC Voltage Input/Output Module

Voltage Input
  • Bipolar: ±5V, ±10V
  • Unipolar: 0 to 5V, 0 to 10V
  • Input impedance: 2MΩ
  • Input bandwidth: 3KHz (typical) at -3dB
Voltage Output
  • Bipolar: ±5V, ±10V
  • Drive: 10mA (max.)
  • Output impedance: <50Ω
Current Output
  • Current: 0 to 20mA, 4 to 20mA
  • Current load resistor: 0 to 500 Ω (Source)
General
  • Isolation (three-way): 3000Vdc
  • Accuracy: ±0.1% of full range (typical)
  • Operation temperature range:-25°C to 75°C
  • Storage temperature range:-30°C to 85°C
  • Operation bandwidth: 3KHz
  • Weight: 94 gram
Supply Voltage
  • Input Range: 10 to 30Vdc at 24Vdc (Typical)
  • Consumption: 1.80W (voltage output), 2.30W (current output)

SG-3081 Isolated Current Input / Output Module

Current Input
  • Unipolar: 0 to 20mA, 4 to 20mA
  • Input impedance: 250Ω
Voltage Output
  • Unipolar: 0 to 5V, 0 to 10V
  • Drive: 10mA (max.)
  • Output impedance: <50Ω
Current Output
  • Current: 0 to 20mA, 4 to 20mA
  • Current load resistor: 0 to 500 Ω (Source)
General
  • Isolation (three-way): 3000Vdc
  • Accuracy: ±0.1% of full range (typical)
  • Operation temperature range:-25°C to 75°C
  • Storage temperature range:-30°C to 85°C
  • Operation bandwidth: 3KHz
  • Weight: 95.5 gram
Supply Voltage
  • Input Range: 10 to 30Vdc at 24Vdc (Typical)
  • Consumption: 1.61W (voltage output), 2.10W (current output)

SG-3016 Isolated Strain Gauge Input Module

Voltage Specifications
  • Electrical input: ±10mV, ±20mV, ±30mV, ±50mV, ±100mV
  • Excitation voltage: 1 ~10Vdc (20mA max.)
Voltage Output
  • Bipolar: ±5V, ±10V
  • Unipolar: 0 to 5V, 0 to 10V
  • Output impedance: <50Ω
Current Output
  • Current: 0 to 20mA
  • Current load resistor: 0 to 500 Ω (Source)
General
  • Isolation (three-way): 3000Vdc
  • Accuracy: ±0.1% of full range
  • Bandwidth: 3KHz (typical) at -3dB
  • Operation temperature range:-25°C to 75°C
  • Storage temperature range:-30°C to 85°C
Supply Voltage
  • Input Range: 10 to 30Vdc
  • Consumption: 1.44W (voltage output), 1.74W (current output)
Ordering Information
On-Line Ordering Information    |        View Shopping Cart Contents    |    Checkout
Description Part Number Qty 1-9 Qty 10+  
Isolated DC Voltage Input/Output Module SG-3071
$179.00 $149.00
Isolated DC Current Input/Output Module SG-3081
$179.00 $149.00
Isolated Strain Gauge Input Module SG-3016
$209.00 $179.00
  • You may change quantities from within your cart.
  • If you do not wish to order online call us toll free at 877-275-9606 between the hours of 9-5 Eastern Standard time.

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax