Humidity & Temperature Data Logger
LogTag Recorder for Measuring Temperature and Humidity using Internal Sensors
The LogTag Humidity & Temperature Recorder has been
designed to meet the growing demand for cost effective electronic
temperature & humidity recording solutions. Combining state
of the art technology, innovative design and high volume manufacturing
techniques, the Logtag recorder system provides the most cost
effective, high performance humidity data logging system available
for today's market. One LogTag
Analyser Software Starter Kit is required for operation.
Required with HAXO-8 Data Logger
1. LogTag Analyser Software and Docking Station Kit (#LTI-USB or LTI-RS232)
Features Specifications Documentation Wholesale Pricing
NOTE: NIST Calibration is available.
Large Quantity Discounts available!
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| LogTag Humidity and Temperature Data Logger |
HAXO-8
|
$68.00 |
$63.00 |
 |
| 5 Pack of LogTag Temperature/Humidity Data Loggers |
HAXO-8-5PACK
|
$319.00 |
call |
 |
| 10 Pack of LogTag Humidity & Temperature Data Loggers |
HAXO-8-TENPACK
|
$630.00 |
call |
 |
| Software and Docking Station Kits - Required |
| LogTag Analyser Software and Docking Station (USB) Kit |
LTI-USB
|
$49.00 |
call |
 |
| LogTag Analyser software and docking station (RS232 type) Kit |
LTI-RS232
|
$58.00 |
call |
 |
| Logger, Software and Docking Station Kits (Special Package Pricing) |
| LogTag Complete Starter Kit - Includes (3) Temp/Humidity Data Logger, Software and Docking Station (RS232 type) |
HAXO-8-KIT3-RS232
|
$209.00 |
call |
 |
| LogTag Complete Starter Kit - Includes (3) Temp/Humidity Data Logger, Software and Docking Station (USB) |
HAXO-8-KIT3
|
$199.00 |
call |
 |
| Standard NIST Calibration Service |
| Additional Calibration Points available by contacting Sales at 1-877-275-9606 or by email. |
Data Logger Features
- Fast and easy download. Takes only seconds to download recordings.
- 'Pre-Start' fail-safe logging (records humidity & temperature
data even if not started)
- Low battery indication in software
- Supports humidity filter change
- Recalibration to achieve higher accuracy possible
- High performance at low cost
- Slim credit card sized case
- Customizable alarm settings
- Good for cold chain applications
- Push button start
- Logging inspection mark in log by push button
- Easy to use LogTag Analyser for
Windows™ software that runs on any PC
- Docking station available with USB or RS232 connection
- Designed for FDA 21 CFR Part 11digital signatures
Data Logger Specifications
| Humidity Range |
0 ~ 100%RH but with limitations as detailed
in Humidity Measurement Operating
and Storage Conditions below. |
| Temperature Range |
-40°C ~ +85°C (-40°F ~ +185°F) |
| Humidity Resolution |
better than 0.1%RH |
| Temperature Resolution |
better than 0.1°C or 0.1°F |
| Humidity Accuracy |
better than ±3%RH |
| Temperature Accuracy |
better than ±0.5°C @ 25°C |
| Capacity |
8000 pairs of humidity & temperature readings
(32 Kbytes memory) |
| Sampling frequency |
Adjustable, 30 seconds to several hours |
| Download Time |
Typically with full memory (4000 pairs of readings) in
less than 5 secs depending on computer or readout device
used. |
Standards Compliance
|
IP61 |
| Power Source |
3V Lithium Battery - Non-Replaceable |
| Battery Life |
2 ~ 3 years of normal use |
| Size |
86mm x 54.5mm x 8.6mm |
| Weight |
35g |
| Case Material |
Polycarbonate |
Humidity Measurement Operating and Storage Conditions
This chart shows the normal recommended operating range of the LogTag
Humidity sensor. Conditions outside the recommended range
may temporarily offset the RH signal up to ±3%RH. After return
to normal conditions, the LogTag humidity sensors will
slowly return towards calibration state by itself. Prolonged
exposure to extreme conditions may accelerate the aging of
the HAX0-8 datalogger.
Re-Conditioning Procedure
Exposure of the internal sensor to chemical vapors can interfere with
the internal logging sensors and cause inaccurate readings
to be recorded. In a clean environment, this will slowly
be self-corrected. However, exposure to extreme conditions
or chemical vapors will require the folowing reconditioning
procedure to bring the internal sensor back to calibration
state.
1. 80°C (176°F) at <5%RH for 36 hours (baking) followed by
2. 20-30°C(70-90°F) at >74%RH for 48 hours (re-hydration).
High Levels of pollutants may cause permanent damage to the internal
datalogging sensors.
Exposure to Chemicals
Chemical vapors may interfere with materials used for the humidity sensor.
The diffusion of chemicals into the sensor's polymer may
cause a shift in both offset and sensitivity. In a clean
environment the contaminants will slowly dissipate. The reconditioning
procedure will accelerate this process.
High levels of pollutants may cause permanent damage to the
humidity sensor's polymer.
LogTag Analyser Software Manual (pdf)
Free LogTag Software Download (10.8 MB)
Wholesale/Bulk Pricing of LogTag Temperature/Humidity Recorders
| Part Number |
Qty 1-9 |
Qty 10-29 |
Qty 30-99 |
Qty 100-499 |
Qty 500-999 |
Qty 1000+ |
| HAXO-8 |
$68.00 |
$63.00 |
$62.00 |
$60.00 |
$57.00 |
$49.00 |
MicroDAQ.com accepts Visa, MasterCard and American Express