Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

DASYLab Software - Module Details

Note: Any order for Measurement Computing Products to be Shipped Outside the US will require an "End User Export Agreement" form to be Completed and Returned Prior to Products being Shipped.

DASYLab Software Module Functions

NOTE: All functions are not available with all versions. Please consult the version chart to see if the function, or feature is available.

Inputs/Outputs

Analog In-/Output:
Up to 32 input modules and up to 512 channels up to 2 output modules and up to 32 channels

Digital In-/Output:
Up to 32 input modules and up to 512 channels up to 2 output modules and up to 32 channels

Counter Input:
Up to 2 modules and up to 32 channels

Frequency Output:
Up to 2 modules and up to 32 channels

RS 232 Input:
Extremely expandable with Master/ Slave modules (up to 256 channels with each serial interface)

RS 232 Output:
Output of data or fixed strings for up to 16 channels

Icom Input: Universal serial module to be used with TCP/IP,GPIB and RS232. Master-/ Slave modules with max. 256 channels.

Icom Output:
Output of data or Strings via TCP/IP, GPIB or RS232.

IEEE 48 In-/Output:
supports Measurement Computing GPIB, National Instruments, INES (Input only), or IOtech hardware

DDE In-/Output:
Up to 16 modules and up to 256 channels

IVI Modules:
Handles devices with an IVI compatible interface (Oscilloscope, Multimeter, Function Generator).

MODBUS Modules:
With these modules the MODBUS protocol enables DASYLab to read and write Analog and Digital registers for signed and unsigned integer registers, RS232 only.

Signal Processing

Filter:
Digital IIR filter with definable order and characteristics

Correlation:
Compute correlation coefficient, cross-correlation, autocorrelation, spectrum

Data Window:
Various types of evaluation windows, e.g. rectangle, Gauss, Bartlet and other types

FFT:
Calculate and analyse the discrete spectrum of a signal

Polar/Cartesian:
Convert data values between polar and cartesian coordinates

Electrical Characteritics:
Use the values of Current and Voltage to calculate electric characteristics such as Ueff, cosp etc..

Harmonic Distortion:
Calculates the amplitude and phase of the fundamental frequency and up to 48 harmonic waves.

Period Check:
Calculates the period of a signal by checking its zero crossings.Period Check: Calculates the period of a signal by checking its zero crossings.

Trigger

Start/Stop Trigger:
Selectable start and stop conditions

Pre/Post Trigger:
Amplitude- and slope-based triggers with hysteresis can be specified

Combi Trigger:
Separate signal segments according to logical conditions

SampleTrigger:
Separate intervals of a signal based on a predetermined number of samples.

Trigger on Demand:
Separate samples depending on the dynamic behavior of the signals.

Relay:
Control up to 15 channels with one input signal

Control

Generator:
Signal generation with frequency and amplitude modulation

Switch:
On/off or momentary switch for program and data control

Coded Switch:
Select from preset values by positioning a rotating switch or clicking on buttons.

Slider:
Definable signal range; signal level to be modified during measurement

PID Control:
Proportional, integral and derivative components can be specified freely; new auto-tuning function

Two Point Control: Up to 8 control circuits. Selectable set values are compared with actual values

Time Delay:
Data output after a specified period of time

Latch:
Constantly outputs the input value received last

TTL Pulse Generator:
generates TTL signals with specified duration and switch conditions

Read Variable:
Read Global Variable to generate a data channel to be used in the worksheet

Save Variable:
Save data channel to a Global Variable to be used in module parameters and computations

Router: Route data channel based on control input (amplitude or edge) or based on time (blocks, time, or action controlled)

Block Time:
Extracts the time information of a block and puts time and date into global variables.

Stop:
Stops or interrupts measurement according to specified conditions.

Display

Y/t Chart:
High-speed scope display for fast data with a wide range of display options

X/Y Chart:
Display data blocks of two dependent signals as an X/Y plot, including a Polar plot view.

Polar Plot Chart:
Display data blocks of two dependent signals (X/Y or polar data) in polar coordinates with a third data as flags.

Analog Meter:
Provides several shapes of instruments and offers peak hold and trend indicator options

Digital Meter:
Display the value, with trend display and lower/upper marks. Formats include decimal, hex, octal, binary, ASCII & Clock

Bar Graph:
Bar (horizontal/vertical), thermometer, LED or triangle style; trend and range display options

Chart Recorder:
Chart display for slow data, wide display area and a wide range of display options.

List:
Show data values displayed in list form; several formatting options

Status Lamp:
TTL or Digital Signal status displayed as text and/or images.

Files

Read Data:
Read data from floppy/hard disk files; supports DASYLab, IEEE-32-bit, ASCII format

Write Data:
Write data to floppy/hard disk files; supports DASYLab, IEEE-32-bit, ASCII, Diadem and other formats

ODBC Input/Output:
Exchange data between DASYLab and ODBC data bases.

Data Reduction

Average:
Reduce data using running or summation averages

Block Average/Peak Hold:
Reduce data across data blocks using running or summation average, or using Peak Hold (Minima or Maxima)

Separate:
Reduce data by skipping defined number of samples (or blocks) only; outputs one, then repeats

Merge/Expand:
Merge data from several channels or distribute signals from one channel to others

Cut Out Block:
Output specified samples of a block

Time Slice:
Output data from different channels according to specified switch conditions

Shift Register:
Stores data, one point at a time, into a temporary register, and outputs the block repeatedly

Circular Buffer:
Save an interval of the data stream and send it to the modules output via event driven action

Special Modules

Black Box:
Sub-worksheet unit containing worksheet sections; use for common functions or to manage complexity

Import/Export (Black Box):
Data interface between worksheet levels (main worksheet and Black Boxes)

Action:
Trigger various actions on the occurence of specified events

Message:
Display or print an operator message; play a wave/AVI file; send DDE message; log messages to dedicated printer

Time base:
Extract and output the time or frequency information of a signal

Signal Adaptation:
Synchronize signal flows of differing characteristics

Send e-Mail:
Use Windows E-Mail to send messages to any address including attachments and custom messages/alarms

Mathematics

Formula Interpreter:
Link data from several channels according to mathematical functions entered as formulas

Arithmetic:
Basic arithmetic operations; various operands and exponential functions

Trigonometry:
Sine, tangent, arc- and hyperbolic functions

Differentiation/Integration:
Integration of signal values or slopes in the signal flow

Scaling:
Linear scaling, interpolation tables, RTD linearization, thermocouple linearization, offset adjust, linear conversion factors for a large number of measurement systems

Slope Limitation:
Limit the difference between values

Reference Curve:
Calculates a reference Curve using one or more test runs

Logical Operations:
Evaluate TTL data from input channels; operators AND, OR, XOR, NAND, NOT

Bit Operations:
Perform logical operations (bit by bit) with the received data words, combine, extract, mask and shift operations

Flip-Flop:
Use bistable trigger elements for intermediate data storage (FlipFlop and MonoFlop)

Gray-Code:
Decodes signals generated by position encoders

Channel Comparator:
Compares channels and a constant or to corresponding channels.

Statistics

Statistical Values:
Compute max/min, average, effective values, variance and standard deviation.

Position in Signal:
Extract the value position as defined by sample number, date/time or frequency

Histogram:
Classify data according to specific intervals and numbers of classes

Regression:
Calculate constant, linear or polynomial regression curves up to an order of 20

Counter:
Count blocks, edges, samples, maxima/minima, zero/level crossings and duration

Minimum/Maximum:
Determine extreme values in the signal flow

Check Reference Curve:
Compare the signal with a previously saved reference curve and signal deviations.

Pulse Width Analysis:
Calculates the frequency, length of pulses, pauses and pulse/pause ratio in a TTL pulsed signal.

Channel Sort:
Rearranges the input channels based on their values.

Network

Net Input/Output:
Receive or send data to one or more DASYLab Net via a TCP/IPnetwork

Message Input/Output:
Receives or Sends messages from or to other DASYLab Net via a TCP/IP network.

DataSocket Import/Export:
Exchange data with OPC server via network.

Analysis Add-On (optional)

Sequence Generator:
Generate curves and ramps of different types which can be combined in many ways.

Transfer Function:
The Transfer and Coherence functions are calculated for up to 8 pairs of values.

Block Weighting:
Weight each sample in block by a predefined function.

Convolution:
Up to 16 Input signals are processed (superimposed) with digital filters.

Write UFF Format:
Write data in the Universal File Format 58 for use in system analysis.

FFT Filter:
Frequency intervals of up to 16 signals are filtered with defined conditions.

Universal Filter:
Create user defined FIR or IRR Filters with a helpful filter wizard for FIR Filters.

FFT Maximum:
Calculates the maximum of energy of a FFT spectrum by analysing intervals of the frequency band.

n-th Order Harmonic:
Calculates the maximum of the Harmonic up to an order of 20 of FFT data

Rainflow:
Several counting algorithms classify samples for Time-Stress Analysis

Two-channel Classification:
Classifies the values of two diferrent temporal functions to be used for Time-Stress Analysis.

Octave Analysis:
This module is used for One-Third or Octave Analysis of a signal using digital filters optimized to 40KHz

Ordering Information

On-Line Ordering Information    |        View Shopping Cart Contents    |    Checkout
Description Part Number Qty 1-9 Qty 10+  
DASYLab Data Acquisition Software
DASYLab Lite DAQ Software DASYLab_Lite
$499.00 call
DASYLab Basic DAQ Software DASYLab_Basic
$1,299.00 call
DASYLab Full DAQ Software DASYLab_Full
$1,799.00 call
DASYLab Pro DAQ Software DASYLab_Pro
$2,499.00 call
Additional DASYLab Runtime License DASYLab_Runtime
$449.00 call
  • You may change quantities from within your cart.
  • If you do not wish to order online call us toll free at 877-275-9606 between the hours of 9-5 Eastern Standard time.

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax