Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

Wireless Temperature Measurement Module

Measurement Computing Wireless and USB 8 Channel Thermocouple Module

The Measurement Computing Wireless Thermocouple Module is a USB 2.0 full-speed thermocouple sensor module providing 8 differential input channels with wireless communications. The wireless module provides two (2) integrated cold junction compensation (CJC) sensors for thermocouple measurements. The wireless input module is fully software calibrated. An unlimited number of thermocouple modules can communicate with the wireless interface (#WLS-IFC) all in the specifed maximum range.

Included with each Thermocouple Module:
>> AC to USB Power Adapter (2.5 Watt Supply)
>> US Plug
>> USB Cable
>> Universal Library
>> Universal Library for LabView
>> InstaCal and TracerDAQ 2.0 Software

NOTE: 1 Wireless Interface Device (#WLS-IFC) can be used for multiple Wireless Modules. Several Modules can communicate with only a single wireless interface.

Features      Specifications      Documentation

Description Part Number Qty 1-9 Qty 10+  
MCC Wireless Temperature ValuePack (includes WLS-TC and WLS-IFC) WLS-TC-VP
$599.00 call
MCC Wireless 8 Channel Thermocouple Input Module WLS-TC
$549.00 call
Wireless Gateway Device - 1 Required
MCC USB-to-Wireless Interface Module WLS-IFC
$149.00 call
Optional Thermocouples
6ft.Beaded Type J Thermocouple w/ connector TC6-J
$15.00 $14.00
6ft. Beaded Type K Thermocouple w/ connector TC6-K
$15.00 $14.00
6ft. Beaded Type T Thermocouple w/ connector TC6-T
$15.00 $14.00
12" Probe Type K Thermocouple w/connector - 6 ft. cable TCP6-K12
$35.00 $33.00
Subminiature Connector for Type J Wire SMC-J
$5.00 call
Subminiature Connector for Type K Wire SMC-K
$5.00 call
Subminiature Connector for Type T Wire SMC-T
$5.00 call
Patch Style Thermocouple Type J PST-J
$25.00 $20.00
Patch Style Thermocouple Type K PST-K
$25.00 $20.00
Patch Style Thermocouple Type T PST-T
$25.00 $20.00
Type K 24 Gauge 3 ft Long Thermocouple Probe (Limited Quantity - 9 Available) 08515-01
$21.00
$17.00
call
Type T 24 Gauge 3 ft Cable Length Thermocouple Probe (Limited Quantity - 13 Available) 08515-02
$21.00
$17.00
call
Type K 24 Gauge 10ft Cable Length Thermocouple Probe 08516-82
$29.00 $24.00
Optional Accessories
Keyspan USB Server for connecting USB-based Devices ( Data Logger ) over a LAN US-4A
$129.00 call
Optional Software
Das-Wizard Software for USB DAQ Devices Das-Wizard
$149.00 call
DASYLab Lite DAQ Software DASYLab_Lite
$499.00 call
DASYLab Basic DAQ Software DASYLab_Basic
$1,299.00 call
DASYLab Full DAQ Software DASYLab_Full
$1,799.00 call
DASYLab Pro DAQ Software DASYLab_Pro
$2,499.00 call
Additional DASYLab Runtime License DASYLab_Runtime
$449.00 call

Wireless Thermocouple Module Features

  • 8 Temperature Input Channels
  • J, K, R, S, T, N, E and B Type Thermocouples Supported
  • 8 Digital I/O bits User Configurable for Alarming
  • 802.15.4 Wireless Protocol
  • Multiple Temperature Modules can be connected to a single wireless Interface (#WLS-IFC)
  • A Wireless Range Up to 150 ft indoors and 2400 ft Outdoors
  • Lifetime Warranty & Harsh Environment Warranty

Wireless Thermocuple Module Specifications

Sampling Rate 2 Samples/second/channel
A/D Converters Four (4) Dual 24-bit Sigma-Delta type
Number of Channels 8 Differential Channels
Input Isolation 500 VDC minimum between field wiring and USB interface
Channel Configuration Thermocouple Sensor Type
Differential Input Voltage Range Thermocouple: ±0.080 Volts
Absolute Maximum Input Voltage ±25 Volt power on
±40 Volt power off
Input Impedance 5 Gigohm Minimum
Input Leakage Current Open Thermocouple Detect Enabled: 105 nA Maximum
Normal Mode Rejection Ratio 90 dB Minimum
Common Mode Rejection Ratio 100 dB Minimum
Resolution 24 Bits
Input Coupling DC
Warm-up Time 30 Minutes Minimum
Open Thermocouple Detect Automatically enabled when the channel pair is configured for thermocouple sensors. The maximum open detection time is 3 seconds.
CJC Sensor Accuracy 15 °C to 35 °C ±0.25 °C Typical
±0.5 °C Maximum
0 °C to 70 °C -1.0 to +0.5 °C Maximum
Digital Input/Output Type CMOS
Number of Digital I/O 8 (DIO0 to DIO7)
Digital I/O Configuration Independently configured for input or output.
Power on reset is input mode unless bit is configured for alarm
Digital Pull up/Pull down Configuration All pins pulled up to +5 V via 47 K resistors (default). Pull down to ground (GND) also available.
Digital I/O Transfer Rate
(software paced)
Digital Input - 50 port reads or single bit reads per second typical.
Digital Output - 100 port writes or single bit writes per second typical.
Digital Input High Voltage: 2.0 V Minimum; 5.5 V absolute Maximum
Low Voltage: 0.8 V Maximum; -0.5 V absolute Minimum
Digital Output Low Voltage (IOL = 2.5 mA): 0.7 V Maximum
High Voltage (IOH = -2.5mA): 3.8 V Minimum
Wireless Standard IEEE 802.15.4, ISM 2.4GHz Frequency Band, Non-Beacon, Point-to-Point
Wireless Range Indoor/Urban: Up to 150 ft (50 Meters)
Outdoor RF Line-of-Sight: Up to 2400 ft (750 Meters)
Encryption 128-bit AES (Software Selectable)
Temperature Alarms 8 (1 per Digital I/O line)
Alarm Update Rate 1 Second
USB Cable Type A-B Cable, UL type AWM 2725 or equivalent (min 24 AWG VBUS/GND, min 28 AWG D+/D-)
USB Cable Length 3 Meters Maximum
Dimensions 127mm x 88.9mm x 35.56mm
Operating Temperature Range 0° to 70°C
Storage Temperature Range -40° to 85°C
Humidity 0 to 90% non-condensing

Measurement Computing Wireless Easy Setup Guide
(#WLS-IFC) Wireless Interface Device User Manual
(#WLS-TC) Wireless Thermocouple Module Detailed specifications
(#WLS-TC) Wireless Thermocouple Module User Manual

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax