Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

Track-It Temperature and Humidity Data Loggers

Monarch Instrument Humidity Recorders Available with LCD Display and Optional Analog Input Modules

The Monarch Instrument Track-It™ Temperature & RH Data Logger is a stand alone compact data logger that records up to 64,000 total readings (32,000 if attaching an analog input module). This compact full featured logger has two independent triggers that allow it to be started or stopped in a variety of ways. You can start the logger Instantaneous, when an alarm threshold has been crossed, at a specific time and date (start and stop) or via push button start. This advanced features also allows you to record only during the duration the logger is in an alarm state.

The Track-It™ logger allows for sampling as fast as once every two seconds to once every 24 hours. The Track-It™ Temp Logger can be ordered with or without an LCD display. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. Both models have a multicolored LED indicator to notify user of alarms or general activity. The logger is easily configured using the included Track-It™ Software.

NOTE: NIST Calibration is available.
Large Quantity Discounts Are Available!

  • Specifications
  • Applications
  • Documentation
  • Software
  • Purchase

Humidity Logger Specifications

Data Storage Capacity 64,000 Total Samples/Readings
(NOTE: If Attaching an Analog Input Module, Only 16,000 Temperature and 16,000 Humidity Readings Available.)
Sampling Rate 2 Seconds to 24 Hours (User-Selectable via Software)
Humidity Range: 0 to 100% RH
Accuracy (Typical): ±3% (20% to 80% RH)
Accuracy (Max): ±5% (0 to 100% RH)
Resolution: 0.5% RH
Repeatability: 0.1% RH
Temperature Range: -20°C to 85°C (-4°F to 185°F)
Accuracy (0°C to 50°C): ±1.0°C
Accuracy (-20°C to 85°C): ±2.0°C
Resolution: 0.4°C (1.0°F)
Repeatability: ±0.1°C (±0.2°F)
Time Accuracy ±1 Minute per Year
Triggers Number: 2 Independant Triggers
Modes: Instanteous, Button Control, On Alarm, Time and Date, Day of Week
Battery 3-Volt CR-2032 Lithium Battery (User Replaceable)
Battery Life Typically 1 Year @ 1 Minute Sampling Rate
Operating Modes >> Continuous
>> Start and Stop Using Buttons on Front of Logger
>> Start and Stop at Predetermined Date/Time
>> Start When Alarm Condition is Sensed
Display Not Available on All Models
Type: 4 Digit LCD
Functions: Temperature, Engineering Units, Alarms, Record Mode, Battery Condition, Time/Data Stamp and Memory
LED User Programmable: Alarm Indicator, Recordings and Triggers
Button User Programmable: View Display, Record On/Off, Reset Alarms, Reset Timer
Alarms (2) User Programmable Visual Alarms. High or Low
Communications Interface Direct USB Connection
Software Track-It Software Required (Included)
OS Compatibility Windows XP, Vista and Windows 7 (32 and 64-Bit)
Standards Compliance CE
Dimensions 92.9mm x 19.1mm x 29.5mm (3.66" x 0.75" x 1.16")

Track-It Data Logger Applications

  • Shipping, Transportation and Warehouse Monitoring
  • Monitor Food, Museums, Building, Laboratories, Libraries, Computer Room and Communications Equipment
  • HVAC, Refrigeration, Pharmaceutical, Agriculture Monitoring

Track-It Software

  • Setup, Retrieval, Analysis and Export of Recorded Readings
  • Programs Logging Interval, High and Low Alarms, Engineering Units, Recording Triggers and LCD Displays (if Available)
  • View Tabular Data or Graphs of Recorded Data
  • One Click Export Function to Excel Spreadsheet
  • Compatible with Windows 7, Vista and XP (32 and 64 Bit)
  • Download the Software Here.

Track-IT Temperature Humidity Logger with No Display Track-IT Temperature Humidity Logger with No Display
>> Stores 64,000 Total Readings
>> -20°C to 85°C (Temp) and 0 to 100% (Humidity) Range
>> Includes Rubber Boot, Track-It Software and Battery
Price: $79.00
Part #: 5396-0203

Track-IT Temperature Humidity Logger with Display Track-IT Temperature Humidity Logger with Display
>> Stores 64,000 Total Readings
>> -20°C to 85°C (Temp) and 0 to 100% (Humidity) Range
>> LCD Display Shows Current Readings
>> Includes Rubber Boot, Track-It Software and Battery
Price: $119.00
Part #: 5396-0201

Optional NIST Calibration Service
Standard NIST Temperature Calibration Service Standard NIST Temperature Calibration Service
>> 1 Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders

Price: $49.00
Part #: CAL-NIST-TEMP
Temp:

Standard NIST Temp/Humidity Calibration Service Standard NIST Temp/Humidity Calibration Service
>> 1 Temperature and Humidity Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders

Price: $96.00
Part #: CAL-NIST-RH
Temp/RH:



  • Input Modules
    (Optional)
  • Accessories
    (Optional)

Optional Analog Input Modules

These additional input modules can be swaped or interchanged to measure different voltage and current ranges.

  • Adds (2) Analog Channels for DC Voltage or Current Measurement
  • Stores up to 32,000 DC Voltage or Current Readings
500 mV Analog Input Module 500 mV Analog Input Module
>> Range: 0 to 500 mVolts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Price: $40.00
Part #: 5396-0501

1 Volt Analog Input Module 1 Volt Analog Input Module
>> Range: 0 to 1 Volt DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Price: $40.00
Part #: 5396-0502

5 Volt Analog Input Module 5 Volt Analog Input Module
>> Range: 0 to 5 Volts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Price: $40.00
Part #: 5396-0503

10V Analog Input Module 10V Analog Input Module
>> Range: 0 to 10 Volts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Price: $40.00
Part #: 5396-0504

20 mA Analog Input Module 20 mA Analog Input Module
>> Range: 0 to 20mA Current
>> 2 Input Channels for Measuring Current
>> Stores 32,000 Current Readings
Price: $40.00
Part #: 5396-0505

Optional Accessories

USB Docking Ball Extension USB Docking Ball Extension
>> 5ft USB 2.0 Cable with Upright Stand
>> Handy Extension Cable For All USB Devices
Price: $12.00
Part #: USB-DB

CR2032 Batteries CR2032 Batteries
>> Pack of 5
QuantityPrice Each
1 - 9$10.00
10+ $8.00
Part #: HRB-TEMP-5

Replacement Rubber Sleeve for Track-It Loggers Replacement Rubber Sleeve for Track-It Loggers
>> Splash-Proof Protective Rubber Cover
>> Included with Temperature and Humidity Track-It Loggers
Price: $10.00
Part #: 5396-9903

Track-It Software on CD Track-It Software on CD
Price: $25.00
Part #: 5396-9902

Locking Protective Wall Cover Locking Protective Wall Cover
>> Clear Plastic
>> Dimension: 3 7/8" x 3 1/2" x 2 1/2"
>> Vertical or Horizontal Mounting
>> Includes Locking Key and Mounting Hardware
Price: $12.00
Part #: BTG-EK

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax