JavaScript is either disabled or not supported by your browser.JavaScript must be enabled in order for this page to properly function. Plese enable JavaScript by changing your browser options, then reload this page or click here.
Contact Sales @ (603) 746-5524 for Questions or to Order the MSR165 Shock Vibration Data Recorder.
Shock and Vibration Data Logger
MSR Electronics Data Recorder with Built-in 3-Axis Accelerometer with Rechargeable Lithium-Polymer Battery
 >> Capable of Making 1600 Acceleration (Shock, Vibrations) Measurements per Second in All 3 Axes
>> 32 Measurement Values are Recorded Even Before the Event Takes Place
>> Measurement Range of ±15g in -20°C to 65°C Temperature Range
>> Also Records Temperature, Humidity, Air Pressure, Light and 4 Analog Input Signals
>> MSR PC Software Manages Settings and View, Edit, Export Measured Data
>> Includes CD Software and USB Cable
Additional Measurement Parameters Available
>> Temperature
>> Humidity
>> Pressure (Air)
>> Light Level
>> Any Analog Input Signal
External Sensors (Temperature, Humidity, Pressure and Light) and 4 Analog Inputs Available. Call 1-603-746-5524 to Order
NOTE: All External Sensors are Available as a Special Order. Large Quantity Discounts Are Available!
All MSR165s are Built to Order - 7-10 Business Day Lead Time is Required.
- Specifications
- Documentation
- Applications
- Purchase
Shock and Vibration Data Logger Specifications
| Measured Parameters |
>> 3-Axis Acceleration (Built-in Internal)
>> Temperature (Internal or External)
>> Relative Humidity (Internal or External)
>> Air Pressure (Internal or External)
>> Light (Internal)
>> Analog Input Signal (External) |
| Acceleration |
Range: ±15g
Accuracy: ±0.15G @25°C |
| Temperature |
Range: -20°C to 65°C (Internal); -55°C to 125°C (External)
Accuracy: ±0.3°C (Internal);±2.0°C (External) |
| Humidity |
Range: 0 to 100% RH, -20°C to 65°C
Accuracy: ±2% (10 to 85% RH, 0°C to 40°C);
±4% (85 to 95% RH, 0°C to 40°C); ±0.5°C (0°C to 65°C) |
| Pressure |
Range: 0 to 2000 mbar Absolute or 0 to 14 Bar Absolute
Accuracy: ±2.5mbar (750 to 1100 mbar Absolute, 25C); ±0.5°C (0°C to 65°C) |
| Light |
Type: SFH 5712 Osram
Range: 0 to 65,000 lx
Accuracy: 100 to 65,000 lx, Max ±5% Linearity Error, Max Sensitivity at 500 nm
Resolution: 4 lx
Temperature Coefficient: 0°C to 50°C, <0.2%/K |
| Analog Input |
Number: 4 (Each Channel Configured for Separate Ranges)
Range: 0 to 3.0 Volts (Standard)**
Resolution: 12 Bits
Note: Additional Ranges Available
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Call 603-746-5524 to Order |
| Sampling Rate |
Acceleration: Up to 1600/s
Temperature: 1/s to 12 Hours
Humidity: 1/s to 12 Hours
Pressure: 1/s to 12 Hours
Light Level: 1/s to 12 Hours |
| Data Storage Capacity |
Approximately 2,000,000 Total Readings Additional Storage Available with Standard SD (>4 GB) Card |
| Operating Conditions |
Temperature: -20°C to 65°C
|
| Storage Conditions |
Temperature: 5°C to 45°C
Humidity: 10 to 95% RH, non-condensing
|
| Color |
Blue, Anthracite |
| Operating Mode |
Push Button Start/Stop |
| Recording Mode |
Set Bookmark or Start and Stop Recording |
| Power Supply |
Rechargeable Lithium Polymer Battery (900mAh)
>> USB Connection to PC recharges unit
>> At a Measurement Rate of 1600/s up to once every 12 Hours, 3-Axis Acceleration data can be recorded over a period of 6 months |
| Housing Enclosure |
Anodised Aluminum Case, PC, Not Encapsulated , Waterproof |
| Media |
Air, Various Liquids |
| Standards Compliance |
RoHS/WEEE, IP67 |
| Software Compatible |
Windows 7, Vista, XP and 2000 |
| Dimensions |
39mm x 23mm x 72mm |
| Weight |
64 grams
|
Shock and Vibration Recorder Documentation
MSR165 User Manual
MSR165 SD Card Manual
Shock and Vibration Data Logger Applications
- Measure Vibrations in Servo-Axles
- Oscillations at a Tool Carousel in Manufacturing Machine
- Monitoring of Transport Goods
Each MSR165 includes a 3-Axis Acceleration Sensor Additional Internal Sensors are Available Below.
| Optional Temperature and Humidity NIST Calibration Service |
The following external sensors are available for the Shock and Vibration Recorder These External Sensors Replace the Internal Sensors.
>> (#F11015) - Temperature Sensor (-55°C to 125°C) with Cable Length of 0.15 Meter
>> (#F11040) - Temperature Sensor (-55°C to 125°C) with Cable Length of 0.40 Meter
>> (#F11100) - Temperature Sensor (-55°C to 125°C) with Cable Length of 1.00 Meter
>> (#F11160) - Temperature Sensor (-55°C to 125°C) with Cable Length of 1.60 Meter
>> (#F20015) - Humidity Sensor with Cable Length of 0.15 Meter
>> (#F20040) - Humidity Sensor with Cable Length of 0.40 Meter
>> (#F20100) - Humidity Sensor with Cable Length of 1.00 Meter
>> (#F20160) - Humidity Sensor with Cable Length of 1.60 Meter
>> (#F30015) - Air Pressure Sensor (2.0 bar) with Cable Length of 0.15 Meter
>> (#F31015) - Air Pressure Sensor (14 bar) with Cable Length of 0.15 Meter
>> (#F30040) - Air Pressure Sensor (2.0 bar) with Cable Length of 0.40 Meter
>> (#F31040) - Air Pressure Sensor (14 bar) with Cable Length of 0.40 Meter
>> (#F30100) - Air Pressure Sensor (2.0 bar) with Cable Length of 1.00 Meter
>> (#F31100) - Air Pressure Sensor (14 bar) with Cable Length of 1.00 Meter
>> (#F30160) - Air Pressure Sensor (2.0 bar) with Cable Length of 1.60 Meter
>> (#F31160) - Air Pressure Sensor (14 bar) with Cable Length of 1.60 Meter
>> (#F40015) - Light Sensor with Cable Length of 0.15 Meter
>> (#F40040) - Light Sensor with Cable Length of 0.40 Meter
>> (#F40100) - Light Sensor with Cable Length of 1.00 Meter
>> (#F40160) - Light Sensor with Cable Length of 1.60 Meter
>> (#B21114) - 4 Analogue Inputs (0 to 3.0 Volts, 12 bit, Max. 2 External Sensors Possible, Light Sensor Not Available.)
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|