MSR145WD Wireless Data Logger and Recorder with Bluetooth Communications

MSR Electronics Data Recorder Measures Temperature, Humidity, Pressure, Light and Acceleration
SKU
MSR145WD
Please open the Configurator tab to choose your desired options.
  • Measures and Records Temperature, Humidity, Light, Pressure and Acceleration Simultaneously
  • Stores up to 1 Million Total Readings onto Internal Non-Volatile Memory
  • OLED Display Shows Graphical History or Data of Recorded Readings
  • View Data on Any Device (Phone, Tablet or Computer) Using Optional Cloud Storage (MSR SmartCloud)
  • Built-in Bluetooth for Transmitting Data to MSR SmartCloud for Review and Analysis
  • Lithium Polymer Battery is Recharged by Using USB Cable (Included) and PC Computer
  • Data from any number of loggers can be merged synchronously into a single Data Record
  • Made in Switzerland, Swiss Made  Swiss Made - Made in Switzerland

Includes Software CD, USB Cable and Access to MSR SmartCloud

Click on the "Configurator" Tab Below to Choose the Ordering Options

MSR Data Loggers are Built to Order and Not Eligible for Return. All Sales Are Final.
Special order - please allow 4 weeks for this item to ship.

Configure your own custom MSR145WD variant here!

With a few clicks you are able to select your desired datalogger.

  1. Select the housing and the corresponding battery.
  2. Select the configuration.
  3. Choose the FlexSensors if required.
  4. Do you require a base station to transmit the measured values to the MSR SmartCloud?
  5. The use of MSR SmartCloud.
  6. General technical data of the MSR145WD.

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat
material
Item no.
Standard
IP 60
Design housing
with 230 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 17 x 57 mm
(W x H x L)
approx. 27 g
Air PC, not
encapsulated
145WDB25
Error
Design housing
with 1000 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 25 x 57 mm
(W x H x L)
approx. 43 g
Air PC, not
encapsulated
145WDB23
Error
Waterproof
IP 67
Design housing
with 230 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 17 x 57 mm
(W x H x L)
approx. 36 g
Air,
various liquids
PC,
encapsulated
145WDB26
Error
Design housing
with 1000 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 25 x 57 mm
(W x H x L)
approx. 62 g
Air,
various liquids
PC,
encapsulated
145WDB22
Error

2. Select the configuration.

You can select various internal sensors as well as up to five external sensors or connectors.

Measured parameter /
Measurement/
storage rate
Technical data Internal External (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
Working range:
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±0.1 °C (-25...+55 °C)
±0.3 °C (-40...+125 °C)
Item no. T9
Error
Item no. FT9/020
Error

Item no. FT9/100
Error

Item no. FT9/160
Error

Working range:
-55...+125 °C

Max. deviation:
±0.5 °C (10...+70 °C)
±2 °C (-55...+125 °C)
only available
externally
Item no. FT2/020
Error

Item no. FT2/100
Error

Item no. FT2/160
Error

Connector for thermal
element of Type K

(without sensor)


1/s to every 12 h
Working range:
-200...+1350 °C
only available
externally
Item no. FT3/020
Error

Item no. FT3/100
Error

Item no. FT3/160
Error

Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±2 % rel. humidity
(10...80 %, +25 °C)
±3 % rel. humidity
(80...100 %, +25 °C)
Item no. H3
Error
Item no. FH3/020
Error

Item no. FH3/100
Error

Item no. FH3/160
Error

Air pressure absolute,
with integrated
temperature

1/s to every 12 h
Working range:
10...2000 mbar absolute
external: -40...+85 °C
internal: -20...+65 °C

Max. deviation:
±2 mbar
(750...1100 mbar absolute,
+25 °C)
Item no. P5
Error
Item no. FP10/020
Error

Item no. FP10/100
Error

Item no. FP10/160
Error

Working range:
0...14 bar absolute
-20...+65 °C

Max. deviation:
±50 mbar
(1...10 bar abs., +25 °C)
only available
externally
Item no. FP7/020
Error

Item no. FP7/100
Error

Item no. FP7/160
Error

Fluid pressure
with integrated
temperature

1/s to every 12 h

Material in contact with
media:
  • Stainless Steel
    AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings:
    Viton® 70° Shore
Working range:
-1000...3000 mbar rel.
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP9/020
Error

Item no. FP9/100
Error

Item no. FP9/160
Error

Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP3/020
Error

Item no. FP3/100
Error

Item no. FP3/160
Error

Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
only available
externally
Item no. FP4/020
Error

Item no. FP4/100
Error

Item no. FP4/160
Error

Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
only available
externally
Item no. FP8/020
Error

Item no. FP8/100
Error

Item no. FP8/160
Error

Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
only available
externally
Item no. FP12/020
Error

Item no. FP12/100
Error

Item no. FP12/160
Error

3-axis-acceleration
(static)

1/s to every 12 h
Working range:
-15...+15 g
-20...+65 °C

Max. deviation:
±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Error
Item no. FA/020
Error
Item no. FA/100
Error
Item no. FA/160
Error
Light

1/s to every 12 h
Working range:
0...83 000 lx

Max. sensitivity
at 550 nm
Item no. L3
Error
Item no. FL3/020
Error

Item no. FL3/100
Error

Item no. FL3/160
Error

Connection for
strain gauges
Characteristics:
  • full bridge
  • rated output 1 mV/V
  • bridge voltage 3 V
only available
externally
Item no. FD/020
Error

Item no. FD/100
Error

Item no. FD/160
Error

Analogue inputs
(resolution: 12 bit)

1/s to every 12 h
Input configuration:




only available
externally
Exxxx/020
Error
Exxxx/100
Error
Exxxx/160
Error
Input configuration:




only available
externally
Exxxx/020
Error
Exxxx/100
Error
Exxxx/160
Error
Control terminal Characteristics:
  • Alarm output
  • Input for starting and
    stopping data recording
  • 3 V voltage output
only available
externally
Item no. FY/020
Error
Item no. FY/100
Error
Item no. FY/160
Error
FlexConnector
(only combined with
B22 and B23 cases)
The appropriate
FlexSensors are below
presented for choice.
only available
externally
Item no. FX/020
Error
Item no. FX/100
Error
Item no. FX/160
Error

3. Choose the FlexSensors if required.

If you have selected a FlexConnector or already own an MSR145WD data logger with a FlexConnector, you can order suitable sensors here. Please note only one interchangeable FlexSensor can be connected to the FlexConnector at a time.

Measured parameter /
Measurement/
storage rate
Technical data Item no.
Temperature

1/s to every 12 h
Working range:
-40...+125 °C

Max. deviation:
±0.1 °C (-25...+55 °C)
±0.3 °C (-40...+125 °C)
FXT9/160
Error
Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
-40...+125 °C

Max. deviation:
±2 % rel. humidity
(10...80 %, +25 °C)
±3 % rel. humidity
(80...100 %, +25 °C)
FXH3/160
Error
Fluid pressure
with integrated
temperature

1/s to every 12 h

Material in contact with
media:
  • Stainless Steel
    AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings:
    Viton® 70° Shore
Working range:
-1000...3000 mbar relative
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
FXP9/160
Error
Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
FXP3/160
Error
Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
FXP4/160
Error
Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
FXP8/160
Error
Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
FXP12/160
Error
3-axis-acceleration
with Fast Peak
(800 Hz)

1/s to every 12 h
Working range:
-15...+15 g
-20...+65 °C

Max. deviation:
±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
FXA4/160
Error
Light

1/s to every 12 h
Working range:
0...83 000 lx

Max. sensitivity at 550 nm
FXL3/160
Error

4. Do you require a base station to transmit the measured values to the MSR SmartCloud?

MSR base station Description Item no.
The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR Smart Cloud.

The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR SmartCloud.

N10115
Error

5. The use of MSR SmartCloud.

The cloud solution managed by MSR Electronics GmbH records data measured by MSR data loggers in a database. Through online access to MSR SmartCloud you are able to gain insight into your measured data, manage it, and create alert messages. When ordering the MSR145WD data logger you will automatically receive the access code to MSR SmartCloud.

Service Description
MSR SmartCloud Free access to MSR SmartCloud when you purchase the MSR145WD data logger.
Data capacity up to 100 000 measurements, Data memory up to three months.

6. General technical data of the MSR145WD.

Memory capacity: Over 1 000 000 measured values.
Key button: With the button you can activate and deactivate the display, the BLE-module and the data recording.
LED:  
Blue:
Red:
Yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply: Lithium-polymer battery, rechargeable via the USB connection
OLED display: High-contrast, brilliant OLED (organic light-emitting diode) colour display
to show data and graphical charts, resolution 96 x 64 pixels.
Interface: USB, Bluetooth Low Energy
PC software: MSR Setup, Reader, Viewer and Online software, System requirements: Windows 7 or higher, USB port
Operation conditions:
Temperature: -20...+65 °C
Storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145WD complies with EU-Directives RoHS/WEEE.

Your selection:

Price:
Item no.:

MSR145 Bluetooth Wireless Data Logger Specifications

Measured Parameters Temperature
Relative Humidity (RH) with Integrated Temperature
Air Pressure with Integrated Temperatureration (ie. Determining Position)
Light
Temperature Range: -20°C to 65°C
Accuracy: ±0.2°C (-10°C to 50°C); ±1.0°C (-40°C to 125°C)
Note: Available in C Only.
Humidity Range: 0 to 100% RH @ -20°C to 65°C
Accuracy: ±1.8% (10 to 85% RH); ±4% (85 to 95% RH)
Air Pressure Range: 0 to 2000 mbar Absolute @ -20°C to 65°C
Accuracy: ±2 mbar (750 to 1100 mbar Absolute, 25°C)
Acceleration Range: ±15g @ -20°C to 65°C
Accuracy: ±0.15G @ 25°C
Light Range: 0 to 65,000 lx
Accuracy: 100 to 65,000 lx, Max ±5% Linearity Error, Max Sensitivity at 500 nm
Bluetooth Type: Bluetooth 4.0 Smart
Frequency: 2.4 GHz
Radio Range: Approximately 10 Meters
Note: Communication with Multiple Data Loggers at the Same Time
Sampling Rate 1 Second to 12 Hours
Data Storage Capacity Approximately 1 Million Total Readings
Display Type: High Contrast OLED (Organic Light-Emitting Diode)
Resolution: 96 x 64 pixels
Display Area: 22.14 mm x 15.42mm
Fast Response Time: <10 µs
Wide Viewing Angle:>160°
Alarms None
LEDs Blue: Recording Indicator
Red: Alarm Indicator
Yellow: Battery Charge Indicator
Power Supply Rechargeable Lithium Polymer Battery (260mAh or 900mAh)
(USB Connection to PC Recharges Unit)
Battery Life Variable - Depending on Settings Used 
Operating Mode Push Button Start/Stop
Storage Conditions Temperature: 5°C to 45°C
Humidity: 10 to 95% RH, non-condensing
Enclosure Poly Carbonate (Waterproof Version is Encapsulated)
Media Air and Various Liquids (Waterproof Version)
Standards Compliance RoHS/WEEE
Software Compatible Desktop: Windows 11, 10 and 7 (32 and 64-Bit)
App: Android 4.4+, iPhone 4S+, iPad 3+
NOTE: Not Compatible with iOS 9.X at this Time
Dimensions 230mAh Battery Version: 57mm x 35mm x 17mm
900mAh Battery Version: 57mm x 35mm x 25mm
Weight Standard 230mAh Battery Version: 27 grams
Standard 900mAh Battery Version: 43 grams
Waterproof 230 mAh Version: 36 grams
Waterproof 900 mAh Version: 62 grams
Software Downloads
zip
(Size: 255.38 MB)
Version 6.09.01 Includes ShockViewer Add-On for MSR165 and MSR175.
User Manuals and Product Guides

Mounting Instructions for MSR Shock and Vibration Data Loggers

The data loggers should be force-fitted as close as possible to or on the object to be monitored. Fastening to the packaging or the means of transport will lead to deviating results.

Screw the data loggers to the object at the holes provided. Alternatively, the data loggers can also be fastened with high-strength industrial adhesive tape or cable ties. Magnetic fastening should be avoided. It only acts in the direction of the magnetic field lines - it is not force-locking.

Mounting Instructions for MSR Shock and Vibration Data Loggers
User Manuals and Product Guides

Orientation

Align the Axes of the data Loggers with the main direction of movement. The data loggers can be mounted in any position. Make a note of the position and direction of the axes for later evaluation.

MSR Mounting
Customer Questions
Is the software compatible with Windows 10?
Yes, it will work with Windows10
Please, mind that only logged in users can submit questions