Data Loggers - Your Source for Temperature Data Loggers, Humidity Data Loggers, Pressure Data Loggers,Relative Humidity Data Loggers,CO data loggers,CO2 data loggers,Rainfall Gauges,Soil Moisture Content Measurement and many other data logging,measurement or recording devices

HOBO External Sensors and Input Cables

All of the cables and sensors below can be plugged directly into the HOBO H8 series or HOBO U12 series of data loggers that have external input channels. Accuracy specifications for sensors reflect the combined performance of the logger and sensor.

External Temperature Sensors

TMCx-HD Series of Air/Water/Soil Temperature Sensors

These probes can be plugged directly into the external input jacks of HOBO H8 series or HOBO U12 series of data loggers to measure temperature in air, water, or soil.

Air Water Soil Temperature Sensors for HOBO U12 and H8 Data Loggers
  • Range: -40° to 50°C (-40° to 122°F) in water or soil, -40° to 100°C (-40° to 212°F) in air
  • Accuracy with H8 loggers: ±0.5° at 20°C (±0.9° at 68°F), see plot A1 below (insert probe 0.9" min.)
  • Accuracy with U12 loggers: ±0.25° at 20°C (±0.45° at 68°F), see plot A2 below (insert probe 0.9" min.)
  • Drift: < 0.1°C (0.2°F ) per year
  • Resolution with H8 loggers: 0.41° at 20°C (0.7°F at 68°F), see plot A1 below
  • Resolution with U12 loggers: 0.03° at 20°C (0.05°F at 68°F), see plot A2 below
  • Response time in air: 3 minutes typical to 90% in air moving 1 m/sec (2.2 mph)
  • Response time in stirred water: 1 minute typical to 90%
  • Available in 1.8m, 6.1m, and 15.2m foot cable lengths (6, 20, and 50 foot)
  • Housing: Stainless-steel sensor tip
  • Probe dimensions: 0.5 cm x 2.5 cm (0.20" x 1.0")
  • Weight: 37g (1.3 oz), 125g (4.4 oz), or 280g (9.9 oz)

Note: Sensor tip and cable immersion in fresh water up to 50°C (122°F) for one year; radiation shield strongly recommended for use in sunlight.

Plot A1
Temperature Accuracy and Resolution
with H8 loggers
Temperature  Accuraccy and Resolution with HOBO H8 Data Loggers
Plot A2
Temperature Accuracy and Resolution
with U12 loggers
Temperature Accuracy and Resolution with HOBO U12 Data Loggers

TMC1-HD      $28.00 (1 ft.)
TMC6-HD      $30.00
(6 ft.)
TMC20-HD    $35.00
(20 ft.)
TMC50-HD    $40.00
(50 ft.)
Ordering Information



AC Voltage Transmitters

These self-powered external sensors can be plugged directly into the HOBO H8 series or HOBO U12 series of data loggers that have external input channels.

General Specifications
Ranges: 150 VAC: 90-150 volts RMS
300 VAC: 180-300 volts RMS
Sensor Accuracy: < ±0.1% of span (20% to 120% of range) ± 0.25% of span (10% of range)
Over Range : +20% of span
Over Load : +40% of span
Frequency: 60 Hz AC
Supply: Self-powered
Output: 0-20 mA
Response time to 90%: <240 msec
Operating Conditions: -20° to 70°C (-4° to 158°F); 5 - 96% RH, non-condensing
Housing: Plastic polycarbonate
Mounting: Standard 35 mm DIN rail
Protection Level
Box: According to IP-50 DIN 40050
Terminals: According to IP-10 DIN 40050

Requirements

  • 4-20 mA Cable (#CABLE-4-20mA)
150 VAC Voltage Transmitter: $135.00
300 VAC Voltage Transmitter: $135.00
Ordering Information

Other External Measurements

All of the cables and sensors below can be plugged directly into the HOBO H8 series or HOBO U12 series of data loggers that have external input channels.

Voltage Input Cable
  • 1.8m (6 foot) cable with 13mm (0.5") tinned braided wire leads.
    For voltage input specifications, refer to the specifications for the model you will be using.

Part Number: Cable-2.5-Stereo     $8.00

Voltage input cable for Hobo data loggers


Stainless Steel Temperature Probe (TMC6-HC)

This sensor can be plugged directly into the HOBO H8 series or HOBO U12 series of data loggers that have external input channels for measuring temperature in water or soil.

Food grade stainless steel temperature probe for HOBO H8 Data Loggers and HOBO U12 Data Loggers
  • 102mm (4") food-grade stainless steel probe with pointed tip; 3mm (0.12") diameter
  • Range: -40° to 100°C (-40° to 212°F) in air or water
  • Accuracy with H8 loggers: ±0.5° at 20°C (±0.9° at 68°F), see plot A1 above (insert probe 2" min.)
  • Accuracy with U12 loggers: ±0.25° at 20°C (±0.45° at 68°F), see plot A2 above (insert probe 2" min.)
  • Drift: < 0.1°C (0.2°F ) per year
  • Resolution with H8 loggers: 0.41° at 20°C (0.7° at 68°F), see plot A1 above
  • Resolution with U12 loggers: 0.03° at 20°C (0.05° at 68°F), see plot A2 above
  • Response time in air: 3 minutes typical to 90% in air moving 1m/sec (2.2mph)
  • Response time in stirred water: 15 seconds typical
  • 1.8m cable (6 foot)
TMC6-HC      $75.00
Ordering Information

Other External Measurements

All of the cables and sensors below can be plugged directly into the HOBO H8 series or HOBO U12 series of data loggers that have external input channels.


4-20 mA cable*
  • Range: 0 to 20.1 mA
  • Accuracy with H8 series: ±0.1 mA ±3% of reading
  • Accuracy with U12 series: ±0.02 mA ±2.5% of reading
  • Resolution with H8 : 0.4% of full scale
  • Resolution With U12: 0.03% of full scale
  • 457mm (18") cable with 89mm (3.5") tinned braided wire leads

Part Number: Cable-4-20mA     $22.00

* Note: 4-20mA is not designed for use with Intrinsically Safe (IS) loggers

4-20 mA cable for HOBO data loggers


Split-Core AC Sensors*
  • Range available (AC Amps): 0-20, 0-50, 0-100, 0-200, 0-600
  • Accuracy with H8 loggers: ±5.0% of full scale
  • Accuracy with U12 loggers: ±4.5% of full scale
  • Response time: CTV-A approximately 440 milliseconds, CTV-B approximately 200 milliseconds, CTV-C approximately 100 milliseconds, CTV-D approximately 450 milliseconds, CTV-E approximately 490 milliseconds (from 10% to 90% of amplitude)
  • Input current: AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
  • Voltage rating: 600 VAC
  • Construction and operating environment: Molded plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D and CTV-E units is fully removable).
  • 1.8m cable (6 foot)

*Notes:
1) AC current sensors are not CE approved
2) AC current sensors are not designed for use with Intrinsically Safe (IS) loggers

Split Core AC Sensors for HOBO Data Loggers
Part Number Range Window Size Length Width Height Price
CTV-A 0-20 Amps AC 1.10 x .90" 2.9" 2.58" 1.04" $86.00
CTV-B 0-50 Amps AC 1.10 x .90" 2.9" 2.58" 1.04" $86.00
CTV-C 0-100 Amps AC 1.10 x .90" 2.9" 2.58" 1.04" $86.00
CTV-D 0-200 Amps AC 1.54 x 1.26" 3.92" 4.72" 1.14" $109.00
CTV-E 0-600 Amps AC 2.92 x 2.46" 5.3" 5.91" 1.12" $109.00

NOTE: Use a AC line Splitter to measure current without splitting line cords.

Telaire 7001 Carbon Dioxide (CO2) Sensor
(requires CABLE-CO2 to connect to HOBO data loggers)

The Telaire 7001 is a standalone carbon dioxide(CO2) and temperature monitor that can be used with HOBO U12 Data Logger (datalogger sold separately) with an external input to monitor and record carbon dioxide levels.
Part number: 7001   $449.00    
Telaire CO2 sensor for Hobo Data Loggers

Ordering Information
On-Line Ordering Information    |        View Shopping Cart Contents    |    Checkout
Description Part Number Qty 1-9 Qty 10+  
Waterproof Temperature Sensors:
1ft Air/Water/Soil temperature sensor TMC1-HD
$28.00 $26.00
6ft Air/Water/Soil Temperature Sensor TMC6-HD
$30.00 $28.00
20ft Air/Water/Soil temperature sensor TMC20-HD
$35.00 $33.00
50ft Air/Water/Soil temperature sensor TMC50-HD
$40.00 $38.00
Optional Accessory (Compatible with TMCx-HD Sensors)
Solar Radiation Shield RS3
$59.00 $55.00
Stainless Steel Temperature Probe:
Stainless Steel Temperature Probe (4" Probe with 6' Cable) TMC6-HC
$75.00 $69.00
  
Voltage: 
Voltage Input Cable Cable-2-5-Stereo
$8.00 $7.00
Voltage Transmitters: 
conLab AC Voltage Transmitter - 150 VAC T-CON-ACT-150
$135.00 call
conLab AC Voltage Transmitter - 300 VAC T-CON-ACT-300
$135.00 call
  
4-20mA:
4-20 mA Cable Cable-4-20ma
$22.00 $17.00
 
Split Core AC Sensors:
0-20 Amp split-core AC Current Sensor CTV-A
$86.00 $80.00
0-50 Amp split-core AC current sensor CTV-B
$86.00 $80.00
0-100 Amp split-core AC current sensor CTV-C
$86.00 $80.00
0-200 Amp split-core AC Current Sensor CTV-D
$109.00 $101.00
0-600 Amp split-core AC Current Sensor CTV-E
$109.00 $101.00
Optional AC Current Line Splitter for Split-Core AC Sensors
Extech 3-Prong AC Line Separator 480172
$15.00 call
 
Carbon Dixoide :
Telaire 7001 Carbon Dioxide (CO2) Monitor TELAIRE-7001
$449.00 $439.00
Telaire CO2 Monitor to Data Logger Cable Cable-CO2
$25.00 $23.00
  • You may change quantities from within your cart.
  • If you do not wish to order online call us toll free at 877-275-9606 between the hours of 9-5 Eastern Standard time.

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax