Data Loggers
Other Products
More Information
MicroDAQ.com, Ltd. Toll Free Phone: © 2010 MicroDAQ.com |
Compressed Air Flow MeterOnset Flowmeter for Compressed Air Systems
>> Measurement Range of 1 to 80 SCFM >> Measures Flow by Maintaining 1 Probe Warmer than the Other >> Calculates the Mass Velocity from the Amount of Heat Required >> Calculates the Flow on the Basis of Pipe Area >> Display Shows Flow Directly with No Setup or Adjustment >> Fits 1" Steel Pipes (2" Steel Pipe Version Available) >> Easy to Install with No Moving Parts or Calibration >> MiliAmp and Pulse Outputs >> Includes 110 Volt DC Power Adapter w/ 20 ft. Cable Compatible with NOTE: Large Quantity Discounts Are Available!
Compressed Air Flow Meter Installation NotesDrilling the holes to install the meter will release some metal shavings into the pipe. When planning the installation, make sure that all downstream equipment is protected by filters, or take other precautions to ensure that shavings do not reach critical equipment or get blown out in a way that could cause injury. For best accuracy, the meter should be installed with at least 20 diameters of straight pipe upstream and three diameters downstream. Avoid installing the meter downstream of any item that could distort or concentrate the flow, such as a partially-closed valve, a regulator, a filter or moisture separator, two closely-spaced elbows in different planes, a long-radius elbow or a curved hose. Allow at least 30 diameters of straight pipe between any such item and the meter. Select a location that meets these requirements and also provides good visibility from the plant floor. If this is not possible, consider using the remote display discussed below. To install the meter, first shut off the supply of air to the pipe where the meter will be mounted and allow the pressure to bleed down. Clamp the drill guide firmly to the pipe, orienting it for best visibility of the meter. Drill the two holes and remove any resulting burrs from the outside of the pipe. Make sure the out-side surface of the pipe is clean and smooth. Once the pipe is prepared, remove the back halves of the rings, insert the probes into the holes in the pipe with the flow arrow pointing in the proper direction, and reassemble the rings. Tighten the cap screws firmly and evenly so that the gaps between the halves of the rings are about equal on both sides of the pipe. If the display is upside down, remove the cover of the meter, rotate it 180 degrees, and reinstall it. Compressed Air Flow Meter Specifications
Compressed Air Flow Meter DocumentationInstructions on Connecting the Air Flow Meter to the H22 Energy Logger and U30 Energy Monitors. View PDF.
MicroDAQ.com accepts
|