Submersible Hydrostatic Level Transducer

Pressure Systems 705 Non-fouling Wastewater Level Transducer

Shock Recorder The Series 705 transducer is an economically-sized non-fouling level transducer featuring a 0.90" non-stick sensing area. It is designed to provide reliable depth measurement in highly viscous wastewater applications. Its welded 316 Stainless Steel or Titanium housing carries an IP 68/NEMA 6P rating and accommodates advanced electronics. The Series 705 Transducer is available in 4 different Outputs and various electrical connection options.

Level Transducer includes
1. Desiccant-filled Vent Filter
Prevents mositure from entering the vent tube for at least 1 year without maintenance. The vent provides an atmospheric reference for the sensor, allowing for the highest possible accuracy. An Aneroid Bellows is available if periodic maintenance is not practical.
2. Flush Elastomeric Outer Diaphragm
Works well in grease and highly liquids that could cause buildup on the measuring end.

Features   Specifications   Product Options   Accessories   Applications   Documentation

NOTES:
Cable is purchased separately. (Shipping Costs on the cable length are approximate and subject to change because of length and transport method)
Only Teflon-coated Elastomeric Diaphragm Pressure Connection is currently available.
Only Vented Gauge Reference Pressure is currently available.

ALL Submersible Transducers are custom made at time of purchase - NO RETURNS OR REFUNDS.

NOTE: To order or learn more about the 705 Level Transducer, please email or call 1-877-275-9606 our sales department.

Submersible Transducer Features

  • Flush Teflon coated Elastometric Diaphragm
  • Custom Level Ranges from 6-115 ft H2O
  • Analog Outputs of 4-20mA or 0-5 VDC
  • Available in Welded 316 Stainless Steel or Titanium Construction
  • Optional Temperature Measurement Output available
  • Custom Polyurethane or Tefzel Cable Lengths

Level Transducer Applications

  • Lift Stations
  • Slurry
  • Pump Control
  • Waste water applications

Level Transducer Optional Accessories

Level Transducer Specifications

Full Scale Level Ranges 6 to 115 ft H2O ( 2 to 35 m H2O)
Proof Pressure 1.5 xFS
Burst Pressure 2.0 xFS
Static Accuracy* ±1.00% FSO
Resolution Infinitesimal
Wetted Materials 316 Stainless Steel or Titanium, Teflon®, Polyurethane or Viton®
Compensated Temp Range 0 to 50 °C
Thermal Error** ±0.10 %FSO/°C ( for level ranges >23" (7m) H20 )
Prorated ( for level ranges <=23" (7m) H20 )
Operating Temp Range -20 to 60 °C
Protection Rating IP 68, NEMA 6P
Electrical Excitation 9 - 30 VDC for mA and VDC output
Electrical Input Current 20 mA ( mA output )
3.5 mA (VDC output )
Electrical Output 4 - 20 mA
0 - 5 VDC
Electrical Zero Offset ± 0.20 mA (for mA output)
<0.1 VDC (for VDC output)
Electrical Output Impedance <10 ohm for VDC output (loop Resistance Diagram )
Electrical Insulation Resistance 100 Mega Ohm at 50 VDC
Electrical Circuit Protection Polarity, surge/shorted output
Electrical Connections 4 options available:
1. Molded Cable Seal
2. 1/2"-14 NPT Male Conduit Fitting with Molded Cable Seal
3. Gland Cable Seal
4. 1/2" - 14 NPT Male Conduit Fitting with Gland Cable Seal
Weight .5 lbs (227 grams)
Cable Jacket Material Polyurethane
Pull Strength 200 lbs (90 kg)
Number of Conductors 4
Conductor Size 22 AWG
Cable Seal Molded Polyurethane Viton® Gland  
Temperature Output Option ( Available for 4-20mA output only)
Temperature Range 0 to 50 °C  
Output Signal 4 - 20 mA  
Temperature Measurement Accuracy ±4 °C  
Lightning Protection (Optional)
Life Expectancy > 1000 operations  
Peak Clamping Voltage 36 volts  
Response Time < 10 nsecs  
* Static accuracy includes the combined errors due to nonlinearity, hysteresis and nonrepeatability on a Best Fit Straight Line ( BFSL ) basis at 25 °C per ISA S51.1
** Thermal error is the maximum allowable deviation from the BFSL due to a change in temperature, per ISA S51.1

Level Transducer Datasheet and Detailed Specifications
Level Transducer User Manual

Level Transducer Product Options

Housing (Casing) Options
1. Stainless Steel
2. Titanium

Output Options
1. Volts DC Output
2. 4-20mA
3. 4-20mA with Temperature Measurement Option 0 to 50°C
4. 4-20mA with Temperature Measurement Option -20 to 60°C

Electrical Connection Options
1. Molded Seal Cable
2. 1/2" - 14 NPT Male Conduit Fitting with Molded Cable Seal
3. Gland Cable Seal
4. 1/2" - 14 NPT Male Conduit Fitting with Gland Cable Seal

 

MicroDAQ.com accepts
Visa, MasterCard and American Express
Buy Data Loggers from Microdaq.com with Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax