LOGiT Current and Voltage Logger
Supco Data Logger Measuring Single Phase AC Current and AC Voltage
The LOGiT current and voltage data logger measures and records single phase AC current and
AC voltage. The logger features alarms, a fast sampling rate of 1 second, single point offset calibration using software and 10,750 data storage per channel. The AC current clamp has a 0 to 300 Amp range and the voltage cables have a range of 0 to 500 Volts AC.
Included with each LCV Data Logger
>> AC Current Clamp
>> Voltage Cables
Required with each LOGiT Data Logger
>> LOGiT Software (#LLS or #LLSU)
>> 9 Volt Battery
NOTE: Large Quantity Discounts Are Available!
Features Specifications
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| LOGiT AC Current and Voltage Logger, includes current clamp and voltage cable |
LCV
|
$199.00 |
call |
 |
| Software and Interface Kit - 1 Required |
| LOGiT PC Software and Serial Interface Cable Kit (Includes Software, Serial Cable and LINT Interface) |
LLS
|
$74.00 |
call |
 |
| LOGiT PC Software and USB Cable Kit (Includes Software, USB Cable and LINTU Interface) |
LLSU
|
$74.00 |
call |
 |
| Battery - Required |
| 9 Volt Lithium Battery, 1200 mAH |
U9VL-FP
|
$10.00 |
call |
 |
| Optional Accessories |
| Supco USB Serial Adapter for Supco Data Loggers |
USBS
|
$62.00 |
call |
 |
| Keyspan USB 4-Port Serial Adapter |
USA-49WG
|
$149.00 |
call |
 |
| Replacement USB Interface Cable for LOGiT Data Loggers |
19449
|
$74.00 |
call |
 |
LOGiT Current and Voltage Logger Features
- 2 Channel Logger: AC Current and AC Voltage
- Store up to 21,500 Samples (1 Channel) or 10,750 (2 Channels)
- Sampling Rate of 1 Second to 18 Hours
- High and Low Alarms
- Single Point Offset Calibration
- Requires LOGiT Software and 9 Volt Battery
LOGiT Current and Voltage Logger Specifications
| Data Storage Capacity |
21,500 Samples (1 Channel: Current or Voltage)
10,750 Samples (2 Channels) |
| Sampling Rate |
1 Second to 18 Hour |
| Alarms |
Over and Under Alarms for both Current and Voltage |
| Current Range |
0 to 300 Amps AC |
| Current Accuracy |
±5% |
| Current Resolution |
0.1 Amp AC |
| Voltage Range |
0 to 500 Volts AC |
| Voltage Accuracy |
±1 Volts AC |
| Voltage Resolution |
0.1 Volts AC |
| Time Accuracy |
±100ppm @ 75°F |
| Operating Temperature Range |
Alkaline Battery: 32°F to 140°F (0°C to 60°C)
Lithium Battery: -40°F to 150°F (-40°C to 65°C) |
| Operating Humidity Range |
0% to 95%, non-condensing |
| Storage Temperature |
-40°F to 170°F (-40°C to 77°C) |
| Power Source |
9V Alkaline or Lithium Battery (Sold Separately) |
| Battery Life |
Alkaline Battery: 20 Months
Lithium Battery: 40 Months |
| Calibration |
Single point offset calibration available through
software. Current and voltage are factory calibrated |
| Dimensions |
Logger: 3" x 2.5" x 1.1" (7.6cm x 6.4cm x 2.8cm) |
| Weight |
1.2 lbs. (544 grams) |
Applications
- Compressor and Fan Run Cycles
- Troubleshooting Intermittent problems
- Verification of Power Conditions
- Use three LCV's for Three Phase Applications
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|