LOGiT Dual Temperature Logger
Supco 2 Channel Temperature Logger with External Probes
The LOGiT 2 channel temperature data logger measures and logs temperature readings using 2 external probes. The logger features high and low alarms, fast 1 second sampling rate, single point offset calibration through software, 21,500 storage and long battery life.
Included with each Temperature Logger
>> (2) Temperature Probes
Required with each LOGiT Data Logger
>> LOGiT Software (#LLS or #LLSU)
>> 9 Volt Battery
NOTE: NIST Calibration is available. Large Quantity Discounts Are Available!
Features Specifications Thermocouple Ranges
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| LOGiT Dual Temperature Logger (2 external probes) |
LTT
|
$190.00 |
call |
 |
| Software and Interface Kit - 1 Required |
| LOGiT PC Software and Serial Interface Cable Kit (Includes Software, Serial Cable and LINT Interface) |
LLS
|
$67.00 |
call |
 |
| LOGiT PC Software and USB Cable Kit (Includes Software, USB Cable and LINTU Interface) |
LLSU
|
$56.00 |
call |
 |
| Battery - Required |
| 9 Volt Lithium battery, 1200 mAH |
U9VL-FP
|
$10.00 |
call |
 |
| Standard NIST Calibration Service |
| Optional Accessories |
| USB Serial Adapter |
Cable-USB232
|
$39.00 |
$35.00 |
 |
| USB 4-Port Serial Adapter |
USA-49WG
|
$149.00 |
call |
 |
LOGiT External Temperature Logger Features
- 2 External Temperature Probes
- Store up to 21,500 Samples (10,750 per Channel)
- Sampling Rate of 1 Second to 18 Hours
- High and Low Alarms
- Single Point Offset Calibration through Software
- Requires LOGiT Software and 9 Volt Battery
LOGiT Eternal Temperature Logger Specifications
| Data Storage Capacity |
10,750 Samples for 2 Temperature Probes or
21,500 Samples for 1 Temperature Probe |
| Sampling Rate |
1 second to 18 hours |
| Alarms |
Over and Under Alarms for each probe |
| Temperature Range External Sensors |
-50°F to 300°F (-46°C to 150°C) |
| Temperature Accuracy |
±2°F (1°C) |
| Temperature Resolution |
0.1°F (0.05°C) |
| Time Accuracy |
±100ppm @ 75°F |
| Operating Temperature Range |
9V Alkaline Battery: 32°F to 140°F (0°C to 60 °C)
9V Lithium Battery: -40°F to 150°F(-40°C to 65°C) |
| Operating Humidity Range |
0% to 95% RH, non-condensing |
| Storage Conditions |
Temperature: -40°F to 170°F (-40°C to 77°C) |
| Calibration |
Single point offset calibration available through
software. |
| Dimensions |
3" x 2.5" x 1.1" (7.6cm x 6.4cm x 2.8cm) |
| Weight |
2.5oz (71g) |
| Power Source |
9V Alkaline or Lithium Battery (Sold Separately) |
| Battery Life |
9V Alkaline Battery: 20 Months
9V Lithium Battery: 40 Months |
Applications
- Refrigerators
- Greenhouses
- Florists
- Museums
MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.
No U.S. sales tax
|