Wireless Temperature and Humidity Logger
TandD Wireless Data Recorder with Display and Temp/RH External Sensor
The RTR-53 data logger with external sensor can measure and record temperatures from 0 to +55°C and humidity within
a range of 10 to 95% RH. The logger features wireless data transmission to a collector (Sold Separately) within 100 meters, battery life of 6 months with 1 lithium battery, alarm notifications, 15 sampling intervals and 16K of data storage. Large Battery Option Available.
Required with Wireless Temp/RH Logger
>> Wireless Data Collector (#RTR-5W, #RTR-57U or #RTR-50)
Each Wireless Temp/RH Logger Includes
>> O-Ring, Screws and Silica Gel
>> User Manual
>> Battery
NOTE: NIST Calibration is available.
Large Quantity Discounts available!
Features Specifications Documentation Large Battery Pack Setup
| Description |
Part Number |
Qty 1-9 |
Qty 10+ |
|
| TandD Wireless Humidity and Temperature Logger |
RTR-53
|
$299.00 |
call |
 |
| TandD Wireless Humidity & Temperature Logger - Large Battery Pack Version w/o Batteries |
RTR-53L
|
$309.00 |
call |
 |
| TandD Wireless Humidity & Temperature Logger - Large Battery Pack Version includes Battery |
RTR-53L-B
|
$328.00 |
call |
 |
| Wireless Collector - 1 Required |
| TandD Wireless Data Collector w/ Software and USB Cable |
RTR-57U
|
$419.00 |
call |
 |
| Wireless Data Collector and Repeater |
RTR-50
|
$349.00 |
call |
 |
| TandD Wireless Data Collector with full Network Connectivity |
RTR-5W
|
$579.00 |
call |
 |
| Standard NIST Calibration Service |
| Optional External Sensors |
| TandD Temperature and Humidity Sensor, No Cable |
TR-3310
|
$110.00 |
call |
 |
| Optional Accessories |
| TandD Wall Attachment, Plastic - Limited Quantity (1 In Stock) |
TR-05K2
|
$13.00 $9.00 |
call |
 |
| Wireless Data Collector and Repeater |
RTR-50
|
$349.00 |
call |
 |
| CFR 21 Part 11 Secure Software |
VLD-5US
|
$369.00 |
call |
 |
| TandD Wall Attachment (AI) for TR-5 Series |
TR-05K1
|
$26.00 |
call |
 |
| TandD Wall Attachment (Polycarbonate) for RTR and TR-5 Series Loggers |
TR-05K3
|
$20.00 |
call |
 |
| Wireless Data Collector and Repeater |
RTR-50
|
$349.00 |
call |
 |
| TandD Large Capacity Battery Pack (w/o Battery) |
RTR-05B1
|
$39.00 |
call |
 |
| Extra/Replacement 3.6V 1/2AA Lithium Battery |
HP-B
|
$12.00 |
$11.00 |
 |
Wireless Temp and RH Logger Features
- 2 Channel Wireless Data Recorder with Display and External Temp/RH Sensor
- 15 Different Sampling Interval (1 second to 60 minutes)
- Monitor Environmental Conditons and Transmit Captured Data Wirelesssly
- Audible Alarm when Low/High Thresholds are Met
- Large Capacity Battery Pack Available
- Requires Wireless Data Collector (#RTR-57U ) , Wireless Communications Port (#RTR-50) or Wireless Network Station (# RTR-5W)
- Includes Software, Battery and User Manual
Wireless Temp and RH Logger Specifications
| Measurement Channels |
1 External Temperature and 1 External Humidity Channel |
| External Sensor |
TR-3310 Temperature and RH Sensor with 1m Cable Length |
| Temperature Range |
0°C to 55°C |
| Humidity Range |
10 to +95% RH |
| Resolution |
0.1°C / 1% RH |
| Accuracy |
Avg ±0.3°C
± 5%RH
(at 25°C and 50% RH) |
| Data Storage Capacity |
16,000 Samples (8,000 per Channel) |
| Recording Interval |
1,2,5,10,15,20,30 Seconds / 1,2,5,10,15,20,30,60 Minutes (
Total of 15 choices) |
| Water Resistance |
IP64 (Continuous Spray) |
| Recording Mode |
Endless: Overwrite Oldest Data when Capacity is Full
One-time: Stop Recording when Capacity is Full |
| LCD Display Items |
Current Readings / Recording Settings / Battery Life Warning /
Over Measurement Range Warning / Amount of Recorded Data |
| Power |
Lithium Battery (LS14250(SAFT)) or AC Adaptor (sold separately) |
| Battery Life |
RTR-53: Approx. 6 months
RTR-53L: 2.5 Years
(Battery life depends on measurement environment,
recording interval and battery performance)
|
| Dimension |
62 mm x 47 mm x 19 mm (excluding protrusions / antenna length 20mm) |
| Wireless Method |
FCC Part 15 Section 249 / IC RSS-210 |
| Communication Speed |
When downloading data (Wireless) about 2,000 readings per minute
[Collection of a full unit of data= about 420 seconds (optical
communication= about 160 seconds)] |
| Transmission Distance |
Up to 100 Meters (may vary with conditions) |
| Unit Temp. Resistance |
-40°C to 80°C |
Large Battery Pack Option: The Large Battery Pack provides continuous use for up to 2.5 years. The battery will allow you to measure and record over long periods of time whether the unit is in transit or in a distant place.
Note: Battery life will depend on the recording environment, recording interval, communication frequensy, and ambient temperature. The above battery life test was carried out using brand new batteries and in no way do we guarantee a battery's life.
Removing the battery and not replacing it will result in a loss of all recorded data.
TandD RTR-5 Series of Loggers User Manual (.pdf)
RTR-57 Data Collector Manual (.pdf)

MicroDAQ.com accepts Visa, MasterCard and American Express

All prices are in U.S. Dollars.