SRP-003 8 Channel AC Current, Voltage and Temp Data Logger
ACR 01-0011 SmartReader Plus 3 Data Logger with 7 Inputs for 0 to 5 Volts DC
SKU
01-0011
$689.00
- Measure & Record AC Current, Voltage and Temperature
- 8 Channels: (1) Temperature and (7) 0 to 5 Volts DC Inputs
- Temperature Measurement Range of -40°C to 70°C with a ±0.2°C Accuracy
- 3 Memory and Data Storage Options Available (32 KB, 128K and 1.5MB)
- 25/Second to 8 Hour User-Selectable Sampling Rate
- 3.6 Volt Lithium Battery with 10 Year Life (Factory Replaceable)
Due to Increased Freight Costs, All ACR Systems Orders Must Have a Minimum Order Value of $100
Special order - please allow 6-8 weeks for this item to ship.
SRP-003 ACR Systems SmartReader Plus 3 (Cat# 01-0011) Current, Voltage and Temperature Data Logger Specifications
Channels | 8 (1) Internal Temperature and (7) 0 to 5 Volts DC Inputs for Current Transducers or Single/Three Phase Voltage Transducers |
Temperature | Sensor Type: NTC Thermistor - 10,000 Ohms @ 25°C Range: -40°C to 70°C (-40°F to 158°F) Accuracy: ±0.2°C (±0.3°F) @ 0°C to 70°C Resolution: 0.03°C (0.5°F) @ 25°C |
Voltage | Range: 0 to 5 Volts DC Accuracy (5 to 10A): 3.0% of Reading ± 100mV Accuracy (10 to 40A): 2.5% of Reading ± 50mV Accuracy (40 to 100A): 2.0% of Reading ± 50mV Accuracy (100 to 240A): 2.0% of Reading Resolution: 0.03°C (0.5°F) @ 25°C |
Current | Range: 0.5 to 250 Amps (with Current Probe #CT-253) |
Resolution | 12-Bit (1 Part 4096) |
Data Storage Capacity | 21,500 Readings (#SRP-003-32KB) 87,000 Readings (#SRP-003-128KB) 1,048,000 Readings (#SRP-003-1.5MB) |
Sampling Rate | 25/Second to 8 Hours Note: Battery Pack (#BP-101) or Power Supply (#PS-201) Required for Sampling Rates Faster than 8/Second |
Clock Accuracy | ±2 Seconds per Day |
Operating Modes | Continuous (FIFO) or Stop When Full (Fill then Stop) |
Operating Range | Temperature: -40°C to 70°C (-40°F to 158°F) Humidity: 0 to 95% RH (non-condensing) |
Power Source | 3.6V 1Amp-Hour Lithium Battery (Factory Replaceable) |
Battery Life | 10 Year (Normal Use) Dependant Upon Environment and Sampling Rate |
Power Consumption | 5 to 10 microamps (Continuous) |
Product Approvals | Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission require ments for the Interference Causing Equipment Standard f or Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE) |
Resistance to X-Rays | Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5” |
Communication Type | USB or RS-232 Port (Requires #TR2-USB or TR2-RS232 TrendReader Software Package) |
Housing | Noryl Plastic |
Mounting | Magnetic Backing or Locking Eyelet |
OS Compatibility | Windows 11, 10 and 7 (32 and 64 Bit) |
Standards Compliance | CE |
Weight | 3.75 oz (110 grams) |
Dimensions | 4.2" x 2.9" x 0.9" (10.7cm x 7.4cm x 2.2) |