SRP-003 8 Channel AC Current, Voltage and Temp Data Logger

ACR 01-0011 SmartReader Plus 3 Data Logger with 7 Inputs for 0 to 5 Volts DC
SKU
01-0011
$689.00
  • Measure & Record AC Current, Voltage and Temperature
  • 8 Channels: (1) Temperature and (7) 0 to 5 Volts DC Inputs
  • Temperature Measurement Range of -40°C to 70°C with a ±0.2°C Accuracy
  • 3 Memory and Data Storage Options Available (32 KB, 128K and 1.5MB)
  • 25/Second to 8 Hour User-Selectable Sampling Rate
  • 3.6 Volt Lithium Battery with 10 Year Life (Factory Replaceable)
Requires ACR TrendReader 2 Software and USB Cable Kit

Due to Increased Freight Costs, All ACR Systems Orders Must Have a Minimum Order Value of $100

Special order - please allow 6-8 weeks for this item to ship.

SRP-003 ACR Systems SmartReader Plus 3 (Cat# 01-0011) Current, Voltage and Temperature Data Logger Specifications

Channels 8
(1) Internal Temperature and (7) 0 to 5 Volts DC Inputs for Current Transducers or Single/Three Phase Voltage Transducers
Temperature Sensor Type: NTC Thermistor - 10,000 Ohms @ 25°C
Range: -40°C to 70°C (-40°F to 158°F)
Accuracy: ±0.2°C (±0.3°F) @ 0°C to 70°C
Resolution: 0.03°C (0.5°F) @ 25°C
Voltage Range: 0 to 5 Volts DC
Accuracy (5 to 10A): 3.0% of Reading ± 100mV
Accuracy (10 to 40A): 2.5% of Reading ± 50mV
Accuracy (40 to 100A): 2.0% of Reading ± 50mV
Accuracy (100 to 240A): 2.0% of Reading
Resolution: 0.03°C (0.5°F) @ 25°C
Current Range: 0.5 to 250 Amps (with Current Probe #CT-253)
Resolution 12-Bit (1 Part 4096)
Data Storage Capacity 21,500 Readings (#SRP-003-32KB)
87,000 Readings (#SRP-003-128KB)
1,048,000 Readings (#SRP-003-1.5MB)
Sampling Rate 25/Second to 8 Hours
Note: Battery Pack (#BP-101) or Power Supply (#PS-201) Required for Sampling Rates Faster than 8/Second
Clock Accuracy ±2 Seconds per Day
Operating Modes Continuous (FIFO) or Stop When Full (Fill then Stop)
Operating Range Temperature: -40°C to 70°C (-40°F to 158°F)
Humidity: 0 to 95% RH (non-condensing)
Power Source 3.6V 1Amp-Hour Lithium Battery (Factory Replaceable)
Battery Life 10 Year (Normal Use)
Dependant Upon Environment and Sampling Rate
Power Consumption 5 to 10 microamps (Continuous)
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal
Regulations of the Federal Communications Commission
(FCC). Meets radiated and conducted emission require
ments for the Interference Causing Equipment Standard f
or Digital Apparatus of Industry Canada (ICES-003).
IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity,
EFT/Burst and Radiated Emissions respectively for the
Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30
seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times
that of an airport x-ray machine). Tested for protection
against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object
distance 5”
Communication Type USB or RS-232 Port
(Requires #TR2-USB or TR2-RS232 TrendReader Software Package)
Housing Noryl Plastic
Mounting Magnetic Backing or Locking Eyelet
OS Compatibility Windows 11, 10 and 7 (32 and 64 Bit)
Standards Compliance CE
Weight 3.75 oz (110 grams)
Dimensions 4.2" x 2.9" x 0.9" (10.7cm x 7.4cm x 2.2)
Customer Questions
Is the software compatible with Windows 10?
Yes, it will work with Windows10
Please, mind that only logged in users can submit questions