SRP-009 SmartReader Plus 9 Pulse Data Logger
ACR 2 Channel Logger: Two External Inputs for Pulse Signals and Dry Switch Contact Closures
SKU
01-0130
$1,262.00
- (2) External Inputs for Externally-Generated Pulse Signals and Dry Switch Contact Closures
- Measures up to 4,095 Pulses per Sample Period with Accuracy of ±1 Pulse/Sample Period
- Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
- 25/second to 8 Hour User-Selectable Sampling Rate
- Continuous (FIFO) or Stop When Full Sampling Methods
Due to Increased Freight Costs, All ACR Systems Orders Must Have a Minimum Order Value of $100
Special order - please allow 6-8 weeks for this item to ship.
SRP-009 ACR Systems SmartReader Plus 9 (Cat#01-0130) Pulse Data Logger Specifications
Channels | Two. (Two external inputs for externally-generated pulse signals and dry switch contact closures) |
Maximum Frequency | 100 KHz |
Memory Size | Available in 32 KB (21,500 readings) or 128 K (87,000 readings) versions |
Size | 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”) |
Weight | 110 grams (3.75 ounces) |
Case Material | Noryl Plastic |
External Connector | Removable screw-type terminal strip with Common (-) connection |
Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing) |
Clock Accuracy | ±2 seconds per day |
Battery | 3.6 volt Lithium, 1 Amp-Hour |
Battery Life | 10 year warranty (under normal use), factory replaceable |
Power Consumption | 5 to 10 microamps (continuous) |
Sampling Methods | 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds) 2. Stop when full (Fill-then-stop) |
Sampling Rates | User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds) |
Resolution | 12 bit (1 part in 4,096) |
Mounting | Magnetic backing or locking eyelet |
OS Compatibility | Windows 11, 10 and 7 (32 and 64 Bit) |
Product Approvals | Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission requirements for the Interference Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE) |
Resistance to X-Rays | Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5” |
Pulse Inputs | |
---|---|
Range | 4095 pulses/sample period |
Accuracy | ± 1 pulse/sample period |
Absolute Max. Voltage | +24/-22 volts DC |
Input Impedance | > 1.0 M for Vin < 5V > 4.0 K for Vin > 5V |
Min. Pulse Width 50% Duty Cycle |
Slow input: 2 milliseconds Fast input: 10 microseconds |
Switch Inputs | |
Input Type | Uncommitted "dry" contacts (relay or switch) |
Excitation | 5 microamps contact current 3.6 volts open circuit |
Voltage Inputs | |
Input Type | Active logic signals |
Input Voltage | Low: 0 to 0.5 volts DC High: 4.5 to 24 volts DC |
Customer Questions