SRP-009 SmartReader Plus 9 Pulse Data Logger

ACR 2 Channel Logger: Two External Inputs for Pulse Signals and Dry Switch Contact Closures
SKU
01-0130
$1,262.00
  • (2) External Inputs for Externally-Generated Pulse Signals and Dry Switch Contact Closures
  • Measures up to 4,095 Pulses per Sample Period with Accuracy of ±1 Pulse/Sample Period
  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
  • 25/second to 8 Hour User-Selectable Sampling Rate
  • Continuous (FIFO) or Stop When Full Sampling Methods
Requires ACR TrendReader 2 Software and USB Cable Kit

Due to Increased Freight Costs, All ACR Systems Orders Must Have a Minimum Order Value of $100

Special order - please allow 6-8 weeks for this item to ship.
User Manuals and Product Guides
Application Notes

SRP-009 ACR Systems SmartReader Plus 9 (Cat#01-0130) Pulse Data Logger Specifications

Channels Two. (Two external inputs for externally-generated pulse signals and dry switch contact closures)
Maximum Frequency 100 KHz
Memory Size Available in 32 KB (21,500 readings) or 128 K (87,000 readings) versions
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams (3.75 ounces)
Case Material Noryl Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds)
Resolution 12 bit (1 part in 4,096)
Mounting Magnetic backing or locking eyelet
OS Compatibility Windows 11, 10 and 7 (32 and 64 Bit)
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission requirements for the Interference Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5”

 

Pulse Inputs
Range 4095 pulses/sample period
Accuracy ± 1 pulse/sample period
Absolute Max. Voltage +24/-22 volts DC
Input Impedance > 1.0 M for Vin < 5V
> 4.0 K for Vin > 5V
Min. Pulse Width
50% Duty Cycle
Slow input: 2 milliseconds
Fast input: 10 microseconds
 
Switch Inputs
Input Type Uncommitted "dry" contacts (relay or switch)
Excitation 5 microamps contact current 3.6 volts open circuit
 
Voltage Inputs
Input Type Active logic signals
Input Voltage Low: 0 to 0.5 volts DC
High: 4.5 to 24 volts DC
Customer Questions
Is the software compatible with Windows 10?
Yes, it will work with Windows10
Please, mind that only logged in users can submit questions
Copyright © 2024 MicroDAQ, LLC. All Rights Reserved.