AEMC 2126.05 L261 Single Channel Voltage Data Logger for Recording Voltage Signals up to 600 TRMS Volts AC/DC

L261 Voltage Simple Logger II

AEMC 1 Channel Voltage Data Logger Recording up to 600 Volts AC/DC

Part Number: 2126.05

Ask a question (2)

Be the first to review this product

  • TRMS Voltage Recording up to 600 Volts AC/DC

  • Store up to 240,000 Samples/Readings in Non-Volatile Memory

  • Records up to 64 Samples/Cycle

  • 5 LED Indicators Quickly and Clearly Display Logger Status

  • 100 Hours to 45 Day Battery Life

Includes DataView Software, (2) Color-Coded 5ft Voltage Leads, Color-Coded Alligator Clips and (2) AA Alkaline Batteries

Special order - please allow 5-7 days for this item to ship.


AEMC 2126.05 L261 Voltage Simple Logger Specifications

Number of Channels 1 Channels
Input Connection (2) Recessed 4mm Banana Jacks
Measurement Range 0 to 600 Volts
Resolution 0.1 V
0 to 5V: unspecified
5V to 500 V: ±(0.5% of Reading + 1 Volt)
50V to 600 V: ±(0.5% of Reading + 0.5 Volt)
Sample Rate 64 Samples/Cycle
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM™)
Storage Rate Programmable from 125ms to 1 Day
Recording Length 15 Minutes to 8 Weeks
Programmable Using DataView Software
Data Storage Capacity 240,000 Readings/Measurements
(Stored in Non-Volatile Memory, Retained If Battery is Low or Removed)
Communication USB 2.0 Optically Isolated
Power Source (2) 1.5 Volt AA-cell Alkaline Batteries
Battery Life 100 Hours to > 45 Days
(Dependent on Sample Rate and Recording Length)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Dimensions 4.94" x 2.75" x 1.28" (125mm x 70mm x 32mm)
Weight 6.4 oz (181 grams)

Customer Reviews

Write Your Own Review

You're reviewing: L261 Voltage Simple Logger II

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars


  • Answer:

    The storage rate can be set using the software.  Anywhere from every 125ms to once per day averaging. 

    The logger samples at 64 samples per cycle. 

Leave a Reply

  • Answer:

    The data is retrieved via a USB cable using the software that is included with the logger.  It has onboard memory so an SD card is required or compatible.

Leave a Reply

Ask Your Question

* Required Fields