MN261 AC Current Probe

AEMC Compact Probe Accommodating Conductors up to 250 MCM
SKU
2115.82
$239.40
  • Tape-Wound Cores Improve High and Low End Performance
  • 100mVac/Aac - 10 mVac/Aac Output Signals
  • 0.78" Jaw with Hooked Design Facilitates Clamping and Hooking onto Conductors
  • 40Hz to 10kHz Response
  • Designed to EN 61010, 600 Volt Cat III Safety Standards

Compatible with AEMC L101 Simple Logger II, L102 Simple Logger II and L562 Simple Logger II

Special order - typical lead time is 2-4 weeks, however there may be shipping delays beyond our control

Overview of the AEMC MN261 High Sensitivity Current Probe

The MN261 is a high sensitivity probe with voltage outputs (100mV/A and 10mV/A) and two selectable current ranges of 0.1 to 24A and 0.5 to 240A AC. It is designed to meet even the most stringent demands in industrial and electrical contracting. The MN261 meets EN 61010, 600V, Cat. II safety standards and is CE Marked and UL approved in both Canada and the United States. The probe has a 0.78” (20mm) jaw opening and can accommodate conductors up to 250MCM. The MN261 features a unique hooked jaw design which allows it to securely clamp onto conductors. The MN261 is perfect for use with oscilloscopes and any other BNC terminated instruments.

AEMC 2115.82 MN261 AC Current Probe Specifications

Nominal Range 20 Amp & 200 Amp
Measurement Range 0.1 to 24 Amp, 0.5 to 40 Amp
Transformation Ratio Voltage Output
Output Signal 20 Amp: 100 mV/A
200 Amp: 10 mV/A
Accuracy
(20 Amp Range)
1% of Reading ±50mV
Phase Shift
(20 Amp Range)
N/A
Overload
(20 Amp Range)
24A for 10 min ON, 30 min OFF
Accuracy
(200 Amp Range)
0.5 to 10A: 3% of Reading ± 5mV
10 to 40A: 2.5% of Reading ± 5mV
40A to 100A: 2% of Reading ± 5mV
100 to 240A: 1.0% of Reading ± 5mV
Phase Shift
(200 Amp Range)
0.5 to 10A: N/A
10 to 40A: ≤5.0°
40 to 100A: ≤3.0°
100 to 240A: ≤2.5°
Overload
(200 Amp Range)
240A for 10 Min ON, 30 Min OFF
Frequency Range 40 to 10kHz
Limit Operating Conditions 200A Permanently to 1kHz
Derating Above 3kHz: 200 A x (1/0.333F), F in kHz
Crest Factor 3 @ 200Arms with an Error (due to CF) of 4%
Working/Common Mode Voltage 600 Vrms
Output Termination 6ft BNC
Operating Range Temperature: 14°F to 131°F (-10°C to 55°C)
Humidity: 85% @ 10°C to 35°C (w/o Roll-Off Above 35°C)
Storage Range Temperature: -40°F to 158°F (-30°C to 80°C)
Jaw Opening 0.83" (21mm)
Conductor Size 0.78" (20mm) Maximum
Polycarbonate Material Polycarbonate with Fiberglass Charge, UL94 V0
Double Insulation Yes
Standards Compliance CE, UL (USA and Canada), EN 61010-2-32
Dimensions 13.9cm x 5.16cm x 3.0cm (5.47" x 2.00" x 1.18")
Weight 6.5 oz (180 grams)