PowerPad III Model 8336
- Measures TRMS Voltages up to 1000 Vrms AC or 1200 VDC for 1, 2 and 3-phase Systems
- Measures TRMS Current up to 10 kArms (Sensor Dependent)
- (4) Voltage Inputs and (3) Current Inputs
- Stores Trend Data, 4,000 Alarms, 51 Captured Transients and up to 12 Screen Snap Shots
- VA, var, W, kVAh, VARh, kWh and Totals (per Phase) Measurements and Recordings
Includes (4) Black 10ft Voltage Leads, (4) Black Alligator Clips, (12) Color-Coded Input ID Markers, NiMH Battery, 110/240 V Power Adapter with US Power Cord, Carrying Bag, Soft Carrying Pouch and USB Stick with Software and User Manual
Overview of the AEMC PowerPad Model 8336 Power Quality Analyzer
The PowerPad Model 8336 is a 3-phase power quality analyzer that is easy to use and built with durability in mind. The 8336 takes true RMS single, two, and three phase measurements at 256 samples per cycle and features an easy-to-read color LCD screen. It can measure TRMS voltage up to 1000 Vrms AC or 1200 VDC. The 8336 has four current and five voltage input terminals and is IEC 6100-4-30 Class B and safety rated to 600V CAT IV. It displays and records voltage, current, and power harmonics to the 50th order, including direction, in real time. The 8336 can capture up to 210 transient that contain four cycles for each active input. Offered as a standalone device or with current probes. The 8336 is perfect for technicians and engineers to measure and carry out diagnostics and power quality work on single, dual, and three-phase networks.
AEMC PowerPad III Model 8336 Specifications
Input Terminals | (5) Voltage (4) Current |
Inputs | (4) Voltage (4) Current |
Voltage | TRMS (AC+DC): 2 to 1000 Volts Ratio: Up to 500kV |
Current (TRMS AC+DC) |
MN93 Clamp: 500mA to 200Amps AC MN193 Clamp: 0.005 to 100 Amps AC SR193 Clamp: 1 Amp to 1000 Amps AC AmpFlex or MA193 Clamp: 100mA to 10,000Amps AC MR193 Clamp: 1 Amp to 1300Amps AC/DC SL261 Clamp: 50mA to 100Amps AC/DC Ratio: Up to 60kA |
Data Storage Capacity | 2 GB (Internal) |
Frequency | 40Hz to 69Hz |
Distribution Systems | 1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W and 3P 5W, 2 1/2 Element & Aron Meters |
Power Values | W, VA, var, VAD, PF, DPF, cos φ, tan φ |
Energy Values | Wh, VARh, VAh, VADh |
Harmonics | 1st to 50th Direction, Sequence THD: 0 to 50, phase |
Transients | up to 210 |
Flicker (Pst & Plt) | Yes |
Inrush Mode | Yes > 10 Minutes |
Unbalance | Yes |
Recording | Yes |
Alarm Mode | 40 types, 10,000 Recorded |
Peak | Yes |
Phasor Display | Automatic |
Display | Type: Color 1/4 VGA TFT Screen Dimensions: 320 x 240, 148mm (Diagonal) |
Snapshots | 50 |
Power Supply | 9.6 Volt NiMH Rechargeable Battery Pack (Included) External AC Supply: 110/230 Volts AC ±10% (50/60 Hz) |
Battery Life | > 13 Hours; 25 Hours (Record Mode) |
Communications | USB |
Languages | Supports more than 27 |
Software | DataView (Included) |
OS Compatibility | Windows 11, 10 and 7 (32 and 64 Bit) |
Standards Compliance | CE, IP50, IEC61010-4-30, 1000 V CAT III, 600 V CAT IV |
Weight | 1.95 kgrams (4.3 lbs) |
Dimensions | 24.0cm x 18.0cm x 5.5cm (9.8" x 7.8" x 2.6") |