DataChart 1250 Paperless Data Recorder

Monarch Instrument 2-Channel Paperless Recorder for Measuring DC Voltage, DC Current, Thermocouples, RTD's or Pulse Inputs
SKU
DC1250-U00
$690.00
  • Measures DC Voltage, DC Current, thermocouples, RTD's as well as frequency and pulse inputs
  • Highly Reflective Twisted Nemantic LCD Display with Bright White LED Backlight
  • Measure Display and Record RPM (5 - 600,000 Range)
  • Easy to Follow Configuration Menu
  • Real Time Clock and Internal RAM for Preserving Data

Includes Power Supply and Navigator Lite Software

Special order - please allow 5-7 business days for this item to ship.

Overview of the Monarch DC1250 2-Channel Paperless Data Recorder

The Monarch Instruments DC1250 2-Channel Paperless Recorder is a feature packed data acquisition system that offers two universally configurable inputs for measuring DC voltage, DC current, thermocouples, and RTDs along with frequency and pulse inputs. Included with the DC1250 are four internal alarm setpoints, two alarm relay outputs, and one digital control input. With a maximum storage rate of 100 samples per second, the two channels can capture short duration process signal anomalies. The DC1250 uses a highly reflective twisted nematic LCD with a bright LED backlight. The interface can be configured to display real-time data in a digital or trend format. Configuration is done using an easy-to-follow intuitive menu system. When purchased with the optional Ethernet port the recorder can be accessed remotely over a standard 10/100BaseT network.

Paperless Recorder Specifications

All information is based on Standard version. See Options for Related Specs.

Input Power 9 V DC +/- 0.5 VDCC @ 5VA (Depends on External Loads) provided by external AC wall transformer (provided), non-isolated. 100-240 V AC 50/60 Hz
Output 2 Outputs 5 Volts DC @ 50mA to power external sensors.
Number of Channels 2 Universal, User Selectable Channels
Collection Mode First In - First Out (FIFO) or Stop when Full
Isolation 300 Volt AC/DC Channel Input to Chassis Ground
DC Input Voltage Range: 0-250mV;0-1.25Volt; 0-2.5V;0-5V;0-12.5V;0-25V
Accuracy: 0.1% of Reading
Resolution: 0.025% of full scale
DC Input Current Range: 0-20mA;4-20mA;0-50mA
Accuracy: 0.1% of reading excluding 250 ohm external shunt (required)
Resolution: 0.025% of full scale
Thermocouple Accuracy: 0.3% if full Scale (Typical)
Ambient Temperature Sensor Accuracy: +/- 1.5C
RTD Accuracy: 0.3% of full Scale (typical)
Resolution: 0.1°C
Internal Current Source: 1mA
Pulse Input (Hz) / Speed Input (RPM) Range: 0 to 10,000 Hz / 0 to 600,000 RPM
Accuracy: Freq: +/- 1Hz; RPM: +/- 1RPM
Input: Low <1.0 Vdc; High: > 3.0 < 12.0VDC <br > Pulse Width: 10 microsecond Minimum
Input Impedence > 100k ohms
Measurement Rate Up to 100 samples/second per Channel.
Math Function Y = mx + b; average, hi peak, low peak
Media CompactFlash™ to 2 GB
Display LCD Graphics, 160 x 80 pixels, Black FSTN with white LED backlight. User controlled Backlight level and contrast adjust (Electronic)
Display Modes Trending (horizontal), large Dual Digital Readout, Mixed Mode
User Interface 5 Button Keypad (Dual Function Buttons)
Clock Auto Leap Year and daylight Savings Adjustment. Internal Battery back up
Relay Output Two Alarm Outputs: 30 V 0.5A Form A Relays
Opt-Isolated Input One Input, 5 to 12VDC Activation @ 10mA typical.
Audible Internal Beeper (Multiple Tones available)
Dimensions 96mm x 96mm (1/4DIN) x 152mm (3.78" x 3.78" x 6")
Software Navigator Lite: Allows Viewing of Data in Table Format and Exporting (Included)
Navigator: Graphic Analysis, Printing and Exporting (#Navigator - Sold Separately)
OS Compatibility Windows XP, Vista and Windows 7 (32 and 64-Bit)
Environmental Indoor Use Only:
Installation Category II per IEC 664
Pollution Degree Level II per IEC61010-1
Temperature: -10°C to 50°C Operating per 61010-1
Humidity: Maximum Relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% RH at 40°C.
Customer Questions
Will I be able to down load the recorded data from this instrument to my computer?
The data can be opened on a PC using the software but it must be transferred by the memory card (Compact Flash).  If you want to transfer/view data on the PC in real time you will need to order it with either the USB or Ethernet options. 
Please, mind that only logged in users can submit questions
Copyright © 2024 MicroDAQ, LLC. All Rights Reserved.