PowerScout HD 12 Multi-Circuit Power Submeter
- Designed to Monitor Multiple Independent Loads without Purchasing, Mounting, Wiring or Commissioning Individual Energy Meters
- Monitor Voltage, Current, Power, Energy and Many Electrical Parameters on Single or 3-Phase Systems
- Connect up to 12 Split-Core or RoCoil Rogowski-Style CTs (Sold Separately)
- BACnet and Modbus Protocols with Positive and Negative Objects for Net Metering Projects
- Patented PhaseChek™ LED Indicators Guarantee Correct CT Orientation
- Line-Powered 90 to 600 Volt Phase-Phase Power Supply
- Pulse Outputs Rated at 5mA Max Current/40V Max Open Voltage
- 5 Volt DC, 200 mA Output for Powering Other Devices (Radio or Gateway)
- Includes Viewpoint Software on USB Flash Drive
Available with Enclosure, Mounting Plate or Display
Overview of the Dent Instruments PowerScout 12HD Submeter
The Dent Instruments PowerScout 12 HD is a Multi-Circuit Power Submeter that offers maximum flexibility and versatility. This multi-channel instrument can be configured to monitor multiple electrical circuits simultaneously. It can be used with any of Dent’s split-core, solid-core, or the easy to install RoCoil (Rogowski) current transformers. The PS12HD can monitor any combination of up to 4 three-phase or 12 single-phase electrical devices. The meter provides data updates every second and offers ANSI C12.20-210 Class 0.2 revenue grade accuracy when used with the proper CT. The PowerScout is perfect for data center monitoring, tenant submetering, as well as accountability metering in commercial, retail, and industrial facilities.
The PowerScout HD series of meters are not designed to be standalone energy recorders. They need to be connected as a slave device to a data logger, Remote Terminal Unit (RTU), or a building management host network.
Dent Instruments PowerScout 12 HD Revenue-Grade Networked Power Meter Specifications
Service Type | Single Phase, Split Phase, 3 Phase - 4 Wire (WYE), 3 Phase - 3 Wire (Delta) |
Voltage Channels | 80 to 346 Volts AC Line-to-Neutral, 600 Volts Line-to-Line, CAT III 2 Voltage Reference Inputs |
Current Channels | 12 Channels: 0.525 Volts AC Max, 333 mV CTs, 0 to 4000 Amp Range Depending on Current Transducer |
Maximum Current Input | 150% of Current Transducer Rating (mV CTs) to maintain accuracy. Measure up to 4000 Amps with RoCoil CTs |
Measurement Type | True RMS Using High-Speed Digital Signal Processing (DSP) with Continuous Sampling |
Line Frequency | 50/60 Hz |
Power | From L1 Phase to L2 Phase, 90 - 600 Volts AC, RMS CAT III 50/60 Hz, 500mA AC Max. Use of 12 Volt Auxillary Output Requires 100 Volts AC minimum Input Voltage |
AC Protection | 0.5A Fuse 20kA Interrupt Capacity |
Power Out | Unregulated 12 Volts DC Output, 200 mA, Self-Resetting Fuse |
WaveForm Sampling | 1.8 kHz |
Parameter Update Rate | 1 Second |
Measurements | Volts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, kVA deman, Import (Received) kWh, Export (Delivered) kWh, Net kWh, Import (Received) kVAh, Export (Delivered) kVAh, Net kVAh, Import (Received) kVARh, Export (Delivered) kVARh, Net KVARh, THD, Theta, Frequency. All Parameters for Each Phase and System Total. |
Accuracy | 0.2% (<0.1% typical) ANSI C12.20-2010 Class 0.2 |
Resolution | Values Reported in IEEE-754 Single Precision Floating Point Format (32-Bit) |
Display | 4-line Display, Tri-color Backlight (PhaseCheck™) |
Pulse Output | Open Collector, 5mA Max Current, 40 Volts Max Open Voltage |
Communications | Hardware: RS-485, Ethernet & USB (for Configuration Only) Supported Protocols: Modbus (using SunSpec IEEE-754 Single Precision Floating Point Model) or BACnet Max Distance: 1200 Meters with Data Range of 100K bits/second or Less Supported Baud Rates: 9600, 19200, 38400, 57600, 76800, 115200 baud Data Formats: Modbus, BACnet, MS/TP, Modbus TCP or BACnet IP Parity: None, Even, Odd Stop Bit: 2, 1 Data Bits: 8 |
Wire Connections | 12 to 22 AWG 600 Volts AC, Voltage Connection must be #14 AWG or Larger & 600 Volts AC Rated. |
Mounting | Enclosure or Panel Mount |
PCBA Mounting | 0.5" Standoffs #6 (quantity 4) - User Supplied |
High Voltage Cover | IP40 |
Operating Environment | Temperature: -20 to 60°C (-4°F to 140°F) Humidity: 5 to 95% RH (Non-condensing) |
OS Compatibility | Windows 11, 10 and 7 (32 and 64 Bit) |
Enclosure | ABS Plastic, 94-V0 Flammability Rating, Connections Sized for 1-inch EMT conduit |
Compliance Standards | CE, UL (Conforms to Std. 61010-1) |
Weight | 340 grams (12 ounces) - Excluding CTs |