Graphtec GL240 10-Channel Multifunction Data Logger

  • Graphtec GL240 10-Channel Multifunction Data Logger
  • Graphtec GL240 10-Channel Multifunction Data Logger
  • Graphtec GL240 10-Channel Multifunction Data Logger


Graphtec GL240 Midi Data Logger

Part Number: GL240

Ask a question (2)

Be the first to review this product


  • 10 Channels for Voltage, Temp, Humidity, Pulse and Logic Measurements

  • 10ms to 1 Hour Sampling Rate

  • Isolated Input System Ensures Signals are Not Corrupted by Other Channels

  • Supports 20mV to 100 Volts, Thermocouple Type: R, S, B, K, E, T, J, N and W and 4 Pulse or Logic Channels with Optional Cable (#B-513)

  • Ring and Relay Memory Functions for Saving Data to External Storage

  • New! Transfer Data to Internal Storage (4GB) or External Storage (SD Memory Card up to 32GB)

  • WLAN Compatible Using GL100-WL and Optional Wireless LAN Unit (B-568)


Includes Software, 100 to 240 VAC Adapter and User Manual

$995.00

All Calibration Orders Have a 5 to 7 Business Day Lead Time
1 Year Calibration Due Date Unless Otherwise Specified

$995.00

Graphtec GL240 Midi Data Logger Specifications

Number of Input Channels 10 Analog Channels
External Analog Input 1 Channel: Trigger or Sampling Input
4 Channels: Logic or Pulse Input
External Analog Output Alarm Output 4 Channel
Measurement Ranges Voltage: 20, 50, 100, 200, 500mV; 1, 2, 5, 10, 20, 50V, 100V 1 to 5 Volt FS
Temperature: Thermocouples Type K, J, E, T, R, S, B, N, W
Humidity: 0 to 100% (with Optional Graphtec B-530 Humidity Sensor)
Measurement Accuracy Voltage:
• ±0.1% Full Scale 
Type R Thermocouple:
• 0°C ≤ TS ≤ 100°C: ±5.2°C
• 100°C < TS ≤ 300°C: ±3.0°C
• 300°C < TS ≤ 1600°C: ±(0.05 % of Rdg + 2.0°C)
Type S Thermocouple:
• 0°C ≤ TS ≤ 100°C: ±5.2°C
• 100°C < TS ≤ 300°C: ±3.0°C
• 300°C < TS ≤ 1760°C: ±(0.05 % of Rdg + 2.0°C)
Type B Thermocouple:
• 400°C ≤ TS ≤ 600°C: ±3.5°C
• 600°C < TS ≤ 1820°C: ±(0.05% of Rdg + 2.0°C)
Type K Thermocouple:
-200°C ≤ TS ≤ -100°C: ±(0.05% of Rdg + 2.0°C)
• -100°C < TS ≤ 1370°C: ±(0.05% of Rdg + 1.0°C)
Type E Thermocouple:
• -200°C ≤ TS ≤ -100°C: ±(0.05% of Rdg + 2.0°C)
• -100°C < TS ≤ 800°C: ±(0.05% of Rdg + 1.0°C)
Type T Thermocouple:
• -200°C ≤ TS ≤ -100°C: ±(0.1% of Rdg + 1.5°C)
• -100°C < TS ≤ 400°C: ±(0.1% of Rdg + 0.5°C)
Type J Thermocouple:
• -200°C ≤ TS ≤ -100°C: ±2.7°C)
• - 100°C < TS ≤ 100°C: ±1.7°C)
• 100°C < TS ≤ 1100°C: ±(0.05% of Rdg + 1.0 °C)
Type N Thermocouple:
• 0°C ≤ TS ≤ 1300°C: ±(0.1% of Rdg + 1.0°C)
Type W Thermocouple:
• 0°C ≤ TS ≤ 2000°C: ±(0.1% of Rdg + 1.5°C)
Reference Junction Compensation: ±0.5°C
Analog Input Filter Off, 2, 5, 10, 20, 40 (Moving Average in Selected Number)
Input Terminal Type Screw Terminal (M3 Screw)
Sampling Interval Voltage: 10ms (1 Channel), 20ms (2 Channels), 50ms (5 Channels), 100ms -1 Hour (All Channels)
Temperature: 100ms-1 Hour (All Channels)
Input Method Scans by the photo-MOS-relay, All Channels Isolated, balanced input
Time Scale 1 Second to 24 Hour /Division
Trigger, Alarm Function Trigger Action:
• Start or Stop Capturing Data by the Trigger
Repeat Action:
• Off, On (Auto Rearmed)
Source:
Start: Off, Measured Signal, Alarm, External, Clock, Week or Time
Stop: Off, Measured Signal, Alarm, External, Clock, Week or Time
Combination:
• OR or AND Condition at Level of Signal or Edge of Signal
Condition Setting:
Analog: Rising, Falling, Window-in, Window-out
• Pulse: (High), Falling (Low), Window-in, Window-out
Logic Signal: Pattern (Combination of Each Input Signal in High or Low)
Alarm Output:
• Outputs a Signal When Alarm Condition Occurs in the Input Signal
A/D Converter Sigma-Delta Type, 16Bits (Effective Resolution: 1/40000 of the Measuring Full Range)
Pulse Input Accumulating Count Mode:
• Number of Pulses from the Start of Measurement
Range: 50, 500, 5k, 50k, 500k, 5 M, 50 M, 500 M Counts/FS
Instant Count Mode:
• Counting the Number of Pulses per Sampling Interval
Range: 50, 500, 5k, 50k, 500k, 5 M, 50 M, 500 M Counts/FS
Rotation Count (RPM) Mode:
• Counting the Number of Pulses per second then Convert to RPM (Rotations per Minute)
Range: 50, 500, 5k, 50k, 500k, 5 M, 50 M, 500 M Counts/FS
Display Size: 4.3" TFT Color LCD (WQVGA: 480 x 272 pixels)
Language: English, French, German, Chinese, Korean, Russian, Spanish and Japanese
Information: Waveform in Y-T with Digital Values, Waveform Only, Digital Value, Digital Values and Statistics Values
A/D Converter ΣΔ Type; 16 Bits (Effective Resolution: 1/40,000 of Full Range)
Calculation Function Between Channels: Addition, Subtraction, Multiplication and Division for Analog Inputs
Statistical: Select 2 Calculations from Ave, Peak, Max, Min, RMS
Search Function Search for Analog Signal Levels, Values of Logic, Pulse or Alarm Points in Captured Data
Interface to PC USB (Full Speed), WLAN (Using the Graphtec B-568 Wireless LAN Adapter)
Storage Capacity Internal Storage: 4GB
Media: SD Memory Card (SDHC up to 32GB)
Saved Contents: Captured Data, Setting Conditions, Screen Copy
Capturing Mode Mode: Normal, Ring, Relay
Ring: Saves Most Recent Data (1,000 to 2 Million Readings)
(Size of the Capture Data Will Be Limited to 1/3 of Available Memory)
Replay Data Replays Captured Data That Was Saved (BGD or CSV Format)
Scaling Engineering Unit Function Set Based on the Reference Point of the Scaled Output and Input Signal for Each Channel
Analog Voltage: Converts using 4 Reference Points (Gain, Offset)
Temperature: Converts using 2 Reference Points (Offset)
Pulse Count: Converts using 2 Reference Points (Gain)
Withstand Voltage Between Channels: 350V p-p (1 Minute)
Between Channel / GND: 350 V p-p (1 Minute)
Maximum Input Voltage Between +/- Terminals: 60V p-p
Between Channels: 60V p-p
Between Channel / GND: 60V p-p
Action During Data Capture Displaying parst data (using Dual Display Mode - Current + Past Data)
Hot-swapping the SD Memory Card
Saving Data in Between Cursors
Power Source AC Adapter: 100 to 240 Volts AC, 50/60 Hz (1 pc of Adapter is Attached as Standard Accessory)
DC Power: 8.5 to 24 Volts DC (Graphtec B-514 DC Power Cable is Required)
Battery Pack: Mountable Battery Pack - 7.2 Volts DC, 2900mAh (Requires Graphtec B-569 Battery Pack)
Power Consumption Max. 36 VA
Operating Environment Temperature: 0 to 45°C
Humidity: 5 to 85% RH (Non-condensing)
OS Compatibility Windows 10, 8.1, 8, 7, Vista
Weight 500 grams (Excluding Protrusions)
Dimensions 188mm x 117mm x 42mm (17.64 ounces)

You may also be interested in the following product(s)

Graphtec  B-530 Humidity Sensor

Graphtec B-530 Humidity Sensor

  • Temperature Range: -25°C to 80°C
  • Humidity Range: 0 to 100% RH
  • RH Accuracy: ±3% RH (5% to 98% RH @ 25°C)
  • Response Time: 15 Seconds (90% Response Time When Membrane Filter Installed)
  • Cable Length: 3 Meters
Learn More
$425.00
Welded Tip PFA Thermocouple w/ 72" Bare Wire Leads

Welded Tip PFA Thermocouple w/ 72" Bare Wire Leads

  • 32 AWG Solid PFA Insulated Twisted Pair Leads
  • Lead Length: 72"
  • Operating Range: -75°C to 250°C (-103°F to 482°F)
  • Available in Type J, K, T or N
Learn More
$10.00
Thermocouple Type

Welded Tip PFA Thermocouple w/ 180" Bare Wire Leads

Welded Tip PFA Thermocouple w/ 180" Bare Wire Leads

  • 32 AWG Solid PFA Insulated Twisted Pair Leads
  • Lead Length: 180"
  • Operating Range: -75°C to 250°C (-103°F to 482°F)
  • Available in Type J, K, T or N
Learn More
$17.00
Thermocouple Type

Customer Reviews

Write Your Own Review

You're reviewing: Graphtec GL240 Midi Data Logger

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Value

Questions

  • Answer:

    This product is not rated intrinsically safe nor is it FM rated. 

Leave a Reply

  • Reload captcha
  • Answer:

    Yes, the GL240 can be calibrated for temperature.  In order to do so you would need to purchase thermocouple sensors with it for us to test with.  The other option would be for us to do a simulated thermocouple calibration.  In this case we just test the inputs at a simulated temperature so we don't need the sensors.  If you would like a quote for either service please use the following form - https://www.microdaq.com/contact-microdaq