Lascar USB Thermistor Vaccination Monitoring Kit

SKU
EL-USB-VAC
In Stock
$229.99
  • Monitor Vaccine Temperatures Using External Thermistor Probe
  • Stores 32,000 Temperature Readings onto Non-Volatile Internal Memory
  • Powered by User-Replaceable 1/2 AA Lithium Battery
  • 2 User-Programmable Alarm Thresholds with Visual LED Indicators
  • USB Interface for Set-up and Data Download
  • Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2005
  • Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 1-Year
  • Data Loggers are Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
  • Can Be Used as Either Primary or Backup Data Logger
  • Meets 2018 CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling

Includes NIST Traceable Calibration Certificate, 1 Meter Thermistor Sensor Probe attached to Glycol Bottle, Protective Cap and 1/2 AA 3.6 Volt Lithium Battery. PC Compatible Software Available for Download.

Overview of the Lascar EL-USB-VAC Vaccine Monitoring Digital Data Logger

The Lascar EL-USB-VAC is a standalone USB temperature digital data logger designed for monitoring vaccines in refrigerators and freezers. The logger can measure and store over 32k readings before needing to be downloaded. The logger can be used to measure and record temperature over a range of -40°C to +60°C (-40°F to 140°F) and has an accuracy of +/-0.1°C. The display allows you to cycle through current, minimum, and maximum readings. The free and easy to use EasyLog USB software allows you to quickly configure the loggers and view downloaded data. The EL-USB-VAC includes a 1-year calibration certificate from our ISO/IEC 17025:2017 accredited calibration lab, 1-meter thermistor probe attached to a glycol buffer bottle, protective cap, and 1/2AA 3.6-volt lithium battery.

Software Downloads
exe
(Size: 18.6 MB)
EL-WIN Software Version 7.7 - Compatible with Lascar EL-USB Series and EL-GFX Series Data Loggers
User Manuals and Product Guides
pdf
(Size: 0.5 MB)
Lascar EasyLog Step-By-Step Software Instructions

Lascar USB Vaccine Monitoring Kit Specifications

Temperature Measurement Range: -40°C to 125°C (-40°F to 257°F)
Resolution: 0.5°C (1.0°F)
Accuracy: ±0.5°C (±1.0°F)
Response Time: 40 Minutes to 90%
External Sensor and Glycol Bottle Sensor Type: 75mm Stainless Steel Capped Probe
Cable Length: 1.0 Meter (3ft)
Data Storage Capacity 32,000 Samples
Sampling Rate 1 Second to 12 Hours
Start Modes Immediate, Delayed and Push-to-Start
Operating Range Temperature: -35°C to 80°C (-31°F to 176°F)
Note: Data Logger Should Not be Subjected to Temperatures Outside Operating Range
Battery User Replaceable 1/2AA 3.6V Lithium
Battery Life Typically 2 Years
Software Compatibility Windows 11, 10 and 7 (64-bit and 32-Bit Versions)
LED Green: Recording and Logging
Red: Alarm Thresholds Met
Orange: Low Battery or Logger Data Capacity full
Display Functions Recent Logged Temperature Reading
Maximum Logged Temperature
Minimum Logged Temperature
Alarm Visual - Blinking Red LED
Standards Compliance RoHS
Weight 1.52 oz
Dimensions 13.45 cm x 2.12 cm x 2.39 cm (5.29" x 0.83" x 0.94")
Customer Questions
Can this digital device be placed directly in the freezer and continue to function in temperatures that range between -40 C to -15 C? I am trying to find a digital data logger that does not have a wire running form the inside to the outside the freezer unit.
Generally speaking we don't recommend keeping a logger in a freezer unless it's for short term testing.  This is because the cold temperatures greatly reduce the battery life and make the LCD display (if equipped) not readable.  To use a logger...
Hi, Can you tell me if this data logger is VFC compliant with the accuracy range of +/-1.0F (+/-.5C)? What type of battery does it us and how long is the battery life? Thanks
Yes, this logger meets the current requirements of the VFC program. The logger uses a 1/2 AA battery (included) and has a typical battery life of up to 1-2 years. 
can we ask for two year calibration instead of just one?
As the customer you can request any interval you would like however the manufacturer of this product doesn't recommend anything more than a one year interval.  If you order online you can state the interval you wish us to list in the order notes...
Can the calibration cert be requested for more than 2 years? 3, 5 years? State requires we keep a backup thermo for VFC so these sit in a cabinet, never get used, and we have the privilege of paying for them, then throwing money away every year or 2 when they expire or paying to re-calibrate something we don't use, which is usually more expensive than just buying a new one. (Which kills me!)
While technically you as the customer can request any calibration interval you want, the VFC typically won't accept going with any interval that is greater than 2 years or whichever the manufacturer recommends.  For this particular logger the manufacturer...
Please, mind that only logged in users can submit questions