MicroDAQ.com
Toll Free: 1-877-275-9606
(603) 746-5524
$5.99 Flat Fee Economy Shipping on Most Items Shipped in the Continental USA

You have no items in your shopping cart.

Subtotal: $0.00

Lascar EL-USB-TC USB Thermocouple Data Logger



Lascar EL-USB-TC USB Thermocouple Data Logger

Lascar K, J, T Type Thermocouple Data Recorder with Direct USB Connection and Alarms

Part Number: EL-USB-TC

Ask a question (2)

Be the first to review this product


  • Measure and Record Readings Using External Thermocouple Type J, K or T

  • Stores 32,000 Temperature Readings onto Non-Volatile Internal Memory

  • Powered by User-Replaceable 1/2 AA Lithium Battery with 2-Year Typical Battery Life

  • 2 User-Programmable Alarm Thresholds with Visual LED Indicators

  • Immediate, Delayed and Push-to-Start Data Logging Function


Includes (1) Type K Thermocouple with 1.5 Meter Cable, Protective Cap and 1/2 AA 3.6 Volt Lithium Battery. PC Compatible Software Available for Download.

$76.00
  • Buy 10 for $72.20 each and save 5%
  • Buy 20 for $68.40 each and save 10%

All Calibration Orders Have a 5 to 7 Business Day Lead Time
1 Year Calibration Due Date Unless Otherwise Specified

$76.00

Lascar EL-USB-TC USB Thermocouple Logger Specifications

Measurement Range K-Type Thermocouple: -200°C to 1300°C
J-Type Thermocouple: -130°C to 900°C
T-Type Thermocouple: -200°C to 350°C
Thermocouple Probe
(Included)
Type: 4" Stainless Steel K-Type
Range: 0°C to 200°C (32°F to 392°F)
Green Type K Connector
Part #: K-TYPE-PROBE-1M5
Resolution 1.0°C (2.0°F)
Accuracy ±1.0°C (±2.0°F) @ -10°C to 40°C (14°F to 104°F)
Data Storage Capacity 32,510 Samples
Sampling Rate 1 Second to 12 Hours
Operating Range Temperature: -10°C to 40°C (14°F to 104°F)
(Note: Logger Should Not be Subjected to Temperatures Outside Operating Range)
Battery User Replaceable 1/2AA 3.6V Lithium
Battery Life Typically 2 Years (Dependant on Sampling Rate and Environment)
OS Compatibility Windows 10, 8 and 7 (32-bit and 64-Bit Versions)
LED Green: Recording and Logging
Red: Alarm Thresholds Met
Orange: Low Battery or Logger Data Capacity full
Alarm Visual - Blinking Red LED
Standards Compliance IP61, RoHS
Dimensions 118mm Length x 27mm Width

You may also be interested in the following product(s)

USB Docking Ball Extension Cable

USB Docking Ball Extension Cable

  • 5ft USB 2.0 Cable with Upright Stand
  • Handy Extension Cable For All USB Devices
Learn More
$12.00
BTG-RK Locking Protective Plastic Wall Cover

BTG-RK Locking Protective Plastic Wall Cover

  • Clear Plastic
  • Vertical or Horizontal Mounting
  • Dimensions: 6 3/8" x 3 1/2" x 3"

Includes Locking Key and Mounting Hardware

Learn More
$11.00
6ft. Beaded Thermocouple Sensor Probe w/ Mini Connector

6ft. Beaded Thermocouple Sensor Probe w/ Mini Connector

  • Beaded Thermocouple Probe
  • Insulated 1.8 Meter (6 ft) 30 AWG Wire
  • ANSI Color Coded (J=Black, K=Yellow, T= Blue)
  • Insulation: Teflon (Type J and T) or Glass Braid (Type K)
  • Wire Wound on Spool Caddy and Sub-miniature Connector

Available in Type J, K or T Wire

Learn More
$19.00
Thermocouple Type

Miniature Thermocouple Connector Plug

Miniature Thermocouple Connector Plug

  • Male Miniature Connector Plug with 2 Prongs
  • Color-Coded: Yellow (Type K), Blue (Type T), Black (Type J)
  • Polarized Pins & Connector Body
  • Rated: -58°F to 410°F (-50°C to 210°C)
  • Suitable for Wire Diameters up to 22 AWG (0.025"D);
  • Available in Type J, K or T
Learn More
$6.00
Connector Type

Miniature Thermocouple Connector Jack

Miniature Thermocouple Connector Jack

  • Female Flat Pin Miniature Connector
  • Color-Coded: Yellow (Type K), Blue (Type T), Black (Type J)
  • Polarized Pins & Connector Body
  • Rated: -58°F to 410°F (-50°C to 210°C)
  • Suitable for Wire Diameters up to 22 AWG (0.025"D)
Learn More
$6.00
Thermocouple Type

Customer Reviews

Write Your Own Review

You're reviewing: Lascar EL-USB-TC USB Thermocouple Data Logger

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Value

Questions

  • Answer:

    The overall measurement range of the logger itself is -200°C to +1300°C however the Type K thermocouple it comes with is rated for 0°C to 200°C.  If you need to monitor something beyond that range you will need to use a different thermocouple.  The logger can work with Type K, J, and T thermocouples which are widely available through us and other sources.

    The body of the logger can be used in temps ranging from -10°C to 40°C but keep in mind that the battery life will be reduced when using the logger at the lower or upper end of those ranges. 

    The included thermocouple should work fine for your application measuring liquid up to 205°F but be aware that only the tip of the stainless steel probe should be submerged in liquid.  If the junction of the stainless steel and cable is exposed to moisture it will have a negative impact on the accuracy and eventually shorten the life of the probe. 

Leave a Reply

  • Reload captcha
  • Answer:

    Yes, you can use any thermocouple you would like with this logger.  While the included type k is not long enough for your application you can purchase any other thermocouple we sell or through a 3rd party supplier to use with the logger.  You want to just make sure whatever you purchase comes with a mini plug or you can also repurpose the plug that comes wired to the sensor included with the logger.  They are very easily removed and attached.

    Here is a link to the thermocouples we offer - https://www.microdaq.com/products/thermocouple-sensor-probes.php

Leave a Reply

  • Reload captcha

Ask Your Question

  • Reload captcha

* Required Fields