Lascar 21CFR WiFi Dual Channel Thermistor Vaccination Kit

SKU
EL-WIFI-21CFR-VAC2
$573.99
  • 2 External High Accuracy Thermistors for Vaccine Monitoring
  • Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
  • -40°C to 125°C Temperature Measurement Range with ±0.2°C Accuracy
  • Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
  • Logs up to 30 Days of Readings at 10 Second Sample Rate onto Internal Memory
  • LCD Display Shows Current Temperature Readings, Battery Status and Alarm Status
  • Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2017
  • Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 1-Year
  • Data Logger Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
  • Can Be Used as Either Primary or Backup Data Logger
  • Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling

Includes NIST Traceable Calibration Certificate, (2) 3 Meter Thermistor Probes, 160mm Y Splitter Cable, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software Available as A Free Download.

Special Order - please allow 2-4 weeks for this item to ship

Overview of the Lascar EL-WIFI-21CFR-VAC2 21CFR Compliant Dual Channel Vaccine Monitoring Digital Data Logger

The Lascar EL-WIFI-21CFR-VAC2 is 21CFR part 11 compliant, WIFI enabled dual channel data logger designed for monitoring vaccines refrigerators and freezers. Included with the logger are two external temperature sensors with glycol filled buffer bottles which can monitor temperatures ranging from -40°C to +60°C (-40°F to +140°F) with an accuracy of +/-0.2°C. Utilizing its dual sensors and independently configurable alarms the EL-WIFI21CFR-VAC2 can be used to monitor both a refrigerator and freezer with a single logger. The EL-WIFI-21CFR-VAC2 works with your existing WIFI network, enabling it to stream recorded data wirelessly to the EasyLog 21CFR Cloud (paid service). The kit comes with the logger, two sensors with glycol buffer bottles, 1-year ISO/IEC 17025:2017 calibration certificate, and mounting accessories.

Why purchase a 21 CFR compliant data logger?

The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) provide criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you are required to meet these regulations or have internal data security requirements, then choosing a 21 CFR compliant data logger makes sense. If you don’t need to meet these requirements, we suggest looking at the EL-WIFI-VAC2 instead.

When used with the Lascar 21CFR Part 11 software, the logger has all the same core offerings as the original EasyLog software, but includes additional functionality that includes user permissions, data encryption that can’t be edited, full audit trail, and electronic signatures for all activity.

User Manuals and Product Guides
pdf
(Size: 5.98 MB)

Lascar WiFi Dual Channel Thermistor Vaccine Monitoring Kit Specifications

Temperature Measurement Range: -40°C to 125°C
Resolution: ±0.1°C
Accuracy: ±0.5°C
Data Storage Options Local: Store Recorded Readings on Local Computer/Server for Analysis Using EasyLog 21CFR WiFi PC Software
Remote: Store All Recorded Readings in the EasyLog 21CFR WiFi Cloud for Access from Any Device Any Time and Analysis. EasyLog 21CFR WiFi PC Software is used only for the initial Setup.
Data Storage Capacity Up to 30 Days of Samples at 10 Second Interval
Note: If WiFi Connectivity is Not Available. Once Restored, Data is Wirelessly Transmitted to PC or Cloud, Depending on Setup and Configuration
Sampling Rate 10 Second to 12 Hours
Transmission Rate 1 Minute to 24 Hours
How often Data is Transmitted Back to the PC Using Existing WiFi Network
Operating Range Temperature: -20°C to 60°C (-4°F to 140°F)
Power Source Rechargeable Lithium Polymer Battery
Battery Life Typically about 6 Months
Note: Dependent on Sampling Rate and Environment
21CFR Compliance Permissions Based Use and Access, Authority Based Action Sign-Off, Data Records Cannot Be Edited or Deleted and Complete System Audit Trail
OS Compatibility Desktop PC: Windows 11, 10 and 7 (64-Bit and 32-Bit Versions)
NOTE: EasyLog 21CFR Wi-Fi PC Software for Initial Setup or Local Storage of Data
Mobile/Tablet: Android (Available on Google Play) and iOS (Available on App Store)
Display Functions Current, Min and Max Readings, Battery Life, Wireless Signal Strength, Alarm Event Status, Probe Connection Status,
Maximum Logged Temperature, and Minimum Logged Temperature
Alarm and Alerts Visual - Blinking LED
Cloud-Based Storage and Service Provides Additional Email Alerts Not Available on PC Software
Standards Compliance IP43, 21CFR Part 11 (Data Logger), IP67 (Probe)
Weight 4.4 oz
Dimensions 22mm x 82mm x 70 mm (.87" x 3.23" x 2.76")