MicroDAQ.com
Toll Free: 1-877-275-9606
(603) 746-5524
$5.99 Flat Fee Economy Shipping on Most Items Shipped in the Continental USA

You have no items in your shopping cart.

Subtotal: $0.00

MadgeTech HiTemp140-TSK Extreme High Temperature Data Logger Kit

  • MadgeTech HiTemp140-TSK Extreme High Temperature Data Logger Kit
  • MadgeTech HiTemp140-TSK Extreme High Temperature Data Logger Kit


HiTemp140 Data Logger with Thermal Shield

Madgetech Stainless Steel Data Logger with Low and High Temperature Ranges and Multiple Sensor Options

Part Number: HITEMP140-5.25-TSK-V

Be the first to ask a question about this product

Be the first to review this product


  • HiTemp140 Data Logger with Thermal Shield

  • Exernal Sensor (Multiple Sensor Options Available) to Record Temperatures in Harsh Areas

  • Probe Measurement Range of -200°C to 260°C with a ±0.1°C Calibrated Accuracy

  • Records onto Non-Volatile Internal Memory up to a Total of 32,700 Temperature Readings

  • 1 Second to 24 Hour User-Selectable (via Software) Sampling Rate

  • Stainless Steel Housing Designed for Autoclaves, HACCP, Food, Pasteurization Studies


Requires Communications Interface and Software Kit (#IFC400)

Call for Availability

$589.00

All Calibration Orders Have a 5 to 7 Business Day Lead Time
1 Year Calibration Due Date Unless Otherwise Specified

$589.00

MadgeTech HITEMP140-TSK Extreme Temperature Data Logger with Thermal Shield Kit Specifications

Temperature Sensor Type: 100Ω Platinum RTD
Range: -200°C to 260°C (-328°F to 500°F)
Calibrated Accuracy: ±0.1°C (±0.18°F) @ 20°C to 140°C; ±0.3°C @ -20°C to 19.99°C; ±0.4°C @-40°C to -20.01°C
Resolution: 0.01°C (0.02°F)
Data Storage Capacity 32,700 Total Temperature Readings/Samples
Sampling Rate 1 Second to 24 Hours
Baud Rate 125,000
Time Accuracy ±1 Minute/Month @ 20°C to 30°C (Stand Alone Mode)
Start Modes Immediate Start or Delayed Start (up to 18 Months)
Stop Modes Manual via Software or Specific Date/Time
Data Format Date/Time Stamp, °C, °F, K, °R
Operating Environment Temperature: -200°C to 250°C (-328°F to 482°F)
Humidity: 0 to 100% RH
Power Source 3.6V High Temperature Lithium Battery (User Replaceable)
Battery Life 1 Year @ 1 Minute Sampling Rate
Dependant Upon Environment and Sampling Rate
Communication Type USB Connection to PC Computer via Docking Station (#IFC400 Software and Communications Kit Required)
Housing PTFE Enclosure
OS Compatibility Windows 10, 8, 7, Vista and XP (32-bit and 64-Bit)
Standards Compliance CE, IP68, CE
Weight Data Logger:4.2 oz (120 grams)
Flush Top:6.7 oz (190 grams) - Excluding Data Logger
Vented Top: 9.5 oz (270 grams) - Excluding Data Logger
Dimensions 1.9" x 0.97" (4.8cm x 2.5cm)
HITEMP140-5.25 Probe: 5.25" x 0.188" OD
HITEMP140-5.25-TD Probe: 5.25" x 0.125" OD w/ 0.188 Trans. Dia.
HITEMP140-7 Probe: 7.0" x 0.188" OD/td>

Maximum Exposure Time Chart

Flush Versions
Vented Versions
Ambient Temperature Exposure Time in Air Exposure Time in Liquid Exposure Time in Air Exposure Time in Liquid
-180°C (-292°F) 13 Minutes N/A 15 Minutes N/A
-160°C (-256°F) 15 Minutes N/A 16Minutes N/A
-140°C (-220°F) 17 Minutes N/A 18 Minutes N/A
-120°C (-184°F) 19 Minutes N/A 21 Minutes N/A
-100°C (-148°F) 22 Minutes N/A 2 Minutes N/A
-80°C (-112°F) 27 Minutes N/A 30 Minutes N/A
-60°C (-76°F) 37 Minutes 22 Minutes 42 Minutes 25 Minutes
-40deg;C to 140°C (-40°F to 284°F) Indefinitely Indefinitely Indefinitely Indefinitely
150°C (302°F) 59 Minutes 34 Minutes 66 Minutes 40 Minutes
160°C (320°F) 51 Minutes 29 Minutes 57 Minutes 34 Minutes
170°C (338°F) 43 Minutes 25 Minutes 48 Minutes 29 Minutes
180°C (356°F) 37 Minutes 23 Minutes 42 Minutes 26 Minutes
190°C (374°F) 34 Minutes 20 Minutes 38 Minutes 23 Minutes
200°C (392°F) 31 Minutes 18 Minutes 34 Minutes 21 Minutes
210°C (410°F) 29 Minutes 17 Minutes 32 Minutes 19 Minutes
220°C (428°F) 27 Minutes 16 Minutes 30 Minutes 18 Minutes
230°C (446°F) 25 Minutes 15 Minutes 27 Minutes 17 Minutes
240°C (464°F) 23 Minutes 14 Minutes 26 Minutes 16 Minutes
250°C (482°F) 22 Minutes 13 Minutes 24 Minutes 15 Minutes

You may also be interested in the following product(s)

High Temperature XL-050H 1/2 AA Lithium Battery

High Temperature XL-050H 1/2 AA Lithium Battery

  • Temperature Range: -55°C to 130°C (150°C Max)
  • Nominal Capacity: 0.8Ah @ 0.6mA, 85°C to 2.0 Volts
  • Nominal Voltage: 3.6 Volts
  • Continuous Current: 10mA Max
  • Dimensions: 14.5mm x 25.1mm

As of January 1st, 2017, all orders consisting solely of lithium batteries may be subject to Hazmat fees due to the new lithium battery shipping regulations. This fee will be added to your order at the time of shipment, and is not included in the price at the time of checkout. Please call 877-275-9606 with any questions regarding the purchase of lithium batteries.

Learn More
$15.00

Customer Reviews

Write Your Own Review

You're reviewing: HiTemp140 Data Logger with Thermal Shield

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Value

There are no product questions yet.

Ask Your Question

* Required Fields