  1. Ethernet LAN Humidity and Temperature Data Logger with External Sensors
    TR-72NW
    • Measure and Record Temperature and Humidity Readings Using External Sensor Probes
    • 0°C to 55°C Temperature and 0 to 95% RH Measurement Ranges with ±0.5°C and ±5% RH Accuracy
    • Stores up to 8,000 Readings Between Data Transfers to PC or TandD WebStorage Cloud Service
    • USB or Ethernet LAN Connectivity (Cloud Storage Requires Ethernet and Free Cloud Storage Account)
    • Automatic Transmission of Data (Current or Logged) at Set Interval Using Wired Network and Cloud Storage

    Includes Humidity/Temperature Sensor (#THA-3001), T&D PC Software Available as a Download, (2) AA Alkaline Batteries and User Manual.

    NOTE: Setup Requires Advanced Understanding of Network Connectivity & Security Settings. Not Compatible with Enterprise Wireless Network Security.

  2. Ethernet LAN Better Accuracy Humidity and Temperature Data Logger with External Sensors
    TR-72NW-S
    • Measure and Record Temperature and Humidity Readings Using External Sensor Probes
    • -40°C to 80°C Temperature and 8 to 95% RH Measurement Ranges with ±0.3°C and ±2.5% RH Accuracy
    • Stores up to 8,000 Readings Between Data Transfers to PC or TandD WebStorage Cloud Service
    • USB or Ethernet LAN Connectivity (Cloud Storage Requires Ethernet and Free Cloud Storage Account)
    • Automatic Transmission of Data (Current or Logged) at Set Interval Using Wired Network and Cloud Storage

    Includes Humidity/Temperature Sensor (SHA-3151), T&D PC Software Available as a Download, (2) AA Alkaline Batteries and User Manual.

    NOTE: Setup Requires Advanced Understanding of Network Connectivity & Security Settings. Not Compatible with Enterprise Wireless Network Security.

  3. TandD TR-75NW Ethernet LAN Thermocouple Data Logger
    TR-75NW
    • 2 External Thermocouple Sensor Input for Temperature Measurements in an Indoor Environment
    • Transmission of Recorded Readings to Cloud Storage Using Existing Ethernet LAN for Viewing and Analysis of Data from Any Device
    • User-Replaceable Alkaline Batteries with 10 Day to 1.5 Year Typical Life (Dependent on Auto-Upload Interval)
    • Stores up to 8,000 Measured Readings with Date/Time Stamp if Your Existing Ethernet Communications Not Available
    • Compatible with the Free TandD WebStorage Cloud Service for Viewing your Recorded Readings Anywhere, Anytime
    • TandD PC Software and Apps Available from Apple Store and Google Play for Setup and Reporting

    Includes Alkaline Batteries, Strap and Cable Clamp

    NOTE: Setup Requires Advanced Understanding of Network Connectivity & Security Settings. Not Compatible with Enterprise Wireless Network Security.

  4. VIM-3010 Voltage Input Module
    VIM-3010
    • Measurement Range: 0 to 22 Volts
    • Accuracy (10°C to 40°C): ±(0.5 mV + 0.3% of Reading)
    • Accuracy (-40°C to 10°C): ±(1.0 mV + 0.5% of Reading)
    • Accuracy (40°C to 80°C): ±(1.0 mV + 0.5% of Reading)
    • Measurement Resolution (Up to 400 mV): 0.1 mV
    • Measurement Resolution (Up to 800 mV): 0.2 mV
    • Measurement Resolution (Up to 999 mV): 0.4 mV
    • Measurement Resolution (Up to 3.2 V): 1 mV
    • Measurement Resolution (Up to 6.5 V): 2 mV
    • Measurement Resolution (Up to 9.999 V): 4 mV
    • Measurement Resolution (Up to 22 V): 10 mV
    • Compatible with the RTR-505B Input Module Data Logger