Supported Thermocouple Types: J, K, S, R, B, E, T, N Number of Channels: 32 (64 with TC-32-EXP Expansion Block) A/D Converter: Delta-Sigma Type A/D Resolution: 24-Bit Isolation: 500 Volts DC Absolute Max NOTE: Between Any TC Input Channel and Chassis Ground Channel Configuration: Software-Selectable to Match TC Sensor Type Differential Input Voltage Range: ±78.125 mV Sample Rate: 3 Hz Max (Per Channel) Gain Error: 0.004% FSR (50 Hz or 60 Hz Filtering)
Thermocouple Ranges
J: -210°C to 1200°C K: -270°C to 1372°C S: -50°C to 1768°C R: -50°C to 1768°C B: 0°C to 1820°C E: -270°C to 1000°C T: -270°C to 400°C N: -270°C to 1300°C
Digital Input
Number of Inputs: 8 (16 with TC-32-EXP Expansion Block) Input Voltage Range: 0 to 15 Volts Input Type: Schmitt Trigger, 100 kΩ Pull-Up Resistor, 28.7 kΩ Series Resistor Schmitt Hysteresis: 0.4 Volts (Min); 1.2 Volts (Max) Max. Input Voltage Range: 0 to 20 Volts Max (Power On/Off, Relative to IGND Pins) Transfer Rate (Software Paced): 500 Port Reads per Second Typical Input High Voltage: 1.3 Volts (Min); 2.2 Volts (Max) Input Low Voltage: 1.5 Volts (Max); 0.6 Volts (Min)
Digital Output
Number of Outputs: 32, Shared with Alarms (64 with TC-32-EXP Expansion Block) Configuration: Open Drain Output Output Characteristics: 100 kΩ pull-up, open drain (DMOS transistor) Transfer Rate (Software Paced): Digital Output - 500 Port Reads per Second Typical Off State Leakage Current: 0.1 µA Sink Current Capability: 100 mA Max (Continuous) Per Output Pin
Temperature Alarms
Number of Alarms: 32, Shared with Digital Output Alarm Functionality: Each Alarm Controls its Associated Digital Output Line as an Alarm Output. When an Alarm is Enabled, its Associated Output Line is Driven to the Appropriate State Determined by the Alarm Options and Input Temperature. The Alarm Configurations are Stored in Non-Volatile Memory and Loaded at Power On. Alarm Latency: 1 second, Max. Note: Alarm Settings are applied when changed and at power-on. Temperatures are Constantly Converted on Enabled Channels and Processed for Alarm Conditions Regardless of the Communications Connectivity.
USB Communications
Type: USB 2.0 Full-Speed Compatibility: USB 1.1 and USB 2.0 Connector: Standard B Cable Length: 5 Meters Max Power: Self-Powered (No USB Current Consumed)
Ethernet Communications
Type: 100 Base-TX, 10 Base-T Communication Rates: 10/100 Mbps, Auto-Negotiated Connector: RJ-45, 8 Position Cable Length: 100 Meters Max Additional Parameters: HP Auto-MDIX Support
Power Source
5 Volts DC, 10 W Power Supply (Included)
Operating Range
Temperature: 0°C to 45°C Humidity: 0 to 90% RH Non-Condensing Max
Storage Range
Temperature: -40°C to 85°C Humidity: 0 to 90% RH Non-Condensing Max
OS Compatibility
Windows 11, 10 and 7 (32 and 64-Bit) for Universal Library, LabView Android for UL for Android
Dimensions
482.6mm x 128.6mm x 43.18mm (19.0" x 6.15" x 1.74")