Onset HOBO MX2001-02-SS-S Stainless Steel Water Level Sensor (0 to 100 ft)

SKU
MX2001-02-SS-S
$420.00
  • Water Level Sensor for MX2001 Bluetooth Data Logger, MicroRX Water Level Stations (RX2103 and RX2104) and RX3000 Remote Monitoring Station
  • 0 to 100 ft Water Depth Range and 0.05% FS Typical Accuracy
  • Durable Ceramic Sensor and Non-Vented Design Reduces Maintenance
  • Stainless Steel Housing

Includes Protective Cap

Special order - please be advised that due to supply shortages, some items may require 6 weeks for shipment

Onset HOBO MX2001-02-SS-S Water Level Sensor Specifications

Pressure (Absolute) and Water Level Measurements with MX2001-02-S Operating Range (Sea Level): 0 to 400 kPa (0 to 58 psia, 0 to 30.6 Meters, 0 to 100 ft) of Water Depth
Operating Range (3,000 Meter Altitude): 0 to 400 kPa (0 to 58 psia, 0 to 33.6 Meters, 0 to 111 ft) of Water Depth
Factory Calibrated Range: 69 to 400 kPa (10 to 58 psia) @ 0°C to 40°C (32°F to 104°F)
Burst Pressure: 500 kPa (72.5 psia) or 40.8 Meters (134 ft) Depth
Water Level Accuracy (Typical): ±0.05% FS, 1.5cm (0.05 ft) Water
Water Level Accuracy (Maximum): ±0.1% FS, 3.0cm (0.1 ft) Water
Raw Pressure Accuracy: 0.3% FS, 1.20 kPa (0.17 psi) Maximum Error
Resolution: <0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) Water
Pressure Response Time: <1 second at a Stable Temperature
* With Accurate Reference Water Level Measurement, Known Water Density, and a Stable Temperature Environment. System Water Level Accuracy Equals the Sum of the Barometric Water Level Accuracy plus the Selected Water Level Accuracy.
** Absolute Pressure Sensor Accuracy includes all Sensor Drift, Temperature and Hysteresis-induced Errors.
*** Changes in Temperature: Allow 20 Minutes in Water to Achieve Full Temperature Compensation of the Pressure Sensor. There Can Be Up To 0.5% of Additional Error Due to Rapid Temperature Changes. Measurement Accuracy Also Depends on Temperature Response Time.
Barometric Pressure Operating Range: 66 to 107 kPa (9.57 to 15.52 psia)
Temperature Calibrated Range: -20°C to 50°C (-4°F to 122°F)
Accuracy: ±0.2 kPa (±0.029 psi) Over Full Temperature Range at Fixed Pressure; Max Error: ±0.5% FS
Water Level Accuracy (Typical): ±0.075% FS, 0.3cm (0.01 ft) Water
Water Level Accuracy (Maximum): ±0.15% FS, 0.6cm (0.02 ft) Water
Resolution: <0.01 kPa (0.0015 psi)
Response Time: <1 second at a Stable Temperature
Drift (Stability): <0.01 kPa (0.0015 psi) per Year
Temperature Operating Range (Sea Level): -20°C to 50°C (-4°F to 122°F)
Accuracy: 0.44°C from 0°C to 50°C (0.79°F from 32°F to 122°F)
Resolution: 0.1°C at 25°C (0.18°F at 77°F)
Response Time (90%): 5 Minutes in Water (Typical)
Stability (Drift): 0.1°C (0.18°F) per Year