Onset HOBO Standard Water Level Kit
Temperature and Water Level Measurements
SKU
KIT-S-U20-01
$799.00
- Measure and Log Water Level and Temperature Readings at a Depth up to 13, 30 or 100ft
- A non-Vent Tube Design Allows for Easy Deployment
- (8) User-Defined Logging Intervals Over an 1 Second to 18 Hour Sampling Rate
- Stainless Steel Housing with Lightning Protection Shields Electronics
- Factory-Replaceable 5-Year 2/3 AA Lithium Battery
Includes (1) U20 Water Level Data Loggers, Shuttle Data Transporter (U-DTW-1) and HOBOware Pro Software (BHW-PRO-DLD)
Special order - please be advised that due to supply shortages, some items may require 6 weeks for shipment
Overview of the HOBO KIT-S-U20 Series Water Level Data Logger Kit
The Onset HOBO KIT-S-U20 series are deluxe prebuilt kits designed for high accuracy water level monitoring. These money savings kits include everything needed to start logging as quickly as possible. They are ideal for monitoring water levels and temperatures in wells, streams, lakes, and freshwater wetlands. With multiple depth range options there’s a version that’s perfect for each application. Each kit includes a U20-001 in the selected depth range, a BASE-U-4 base station with couplers, and a copy of HOBOware Pro software.
Onset HOBO® U20 Water Level Data Logger Specifications
Data Channels | 2 Channels (Water Level and Temperature) |
Water Level (Pressure) | Range*: 0 to 9 m (0 to 30 ft); 0 to 207 kPa (0 to 30 psia) Factory Calibrated Range**: 69 to 207 kPa (10 to 30 psia) Water Level Accuracy***: 0.5cm (0.015 ft) water; ±0.05% FS Raw Pressure Accuracy: ±0.3% FS, 0.62 kPa (0.09 psi) Max Resolution: 0.21 cm (0.007 ft), < 0.02 kPA (0.003 psi) Burst Pressure: 310 kPa (45 psia) or 18m (60 ft) depth Response Time (Pressure): < 1 Second to 90% Response Time (Thermal): About 10 Minutes in Water to Achieve Full Temperature Compensation of the Pressure Sensor * Nominal Values at Sea Level ** @ 0°C to 40°C Temperature Range *** Typical Maximum Error Over the Full Temperature and Pressure Calibrated Range |
Temperature | Range: -20°C to 50°C (-4°F to 122°F) Accuracy: ±0.37°C @ 20°C; ±0.5°C @ -5°C to 50°C Resolution: 0.1°C @ 20°C; 0.2°C @ -5°C to 50°C Response Time: 3.5 Minutes in Water to 90% Stability (Drift): ≤0.1°C/year (≤0.18°F/year) |
Data Storage Capacity | 21,700 Total Readings (10,850 Pressure and Temperature) |
Sampling Rate | 1 Second to 18 Hours (User-Specified) Up to 8 Sampling Intervals User-Defined |
Battery | 2/3 AA 3.6 Volt Lithium Battery - Factory Replaceable |
Battery Life | 5 Years @ 1 Minute Sampling Rate (Dependant Upon Environment and Operating Range) |
Battery Status Indication | Battery status displayed at launch or with status screen; Battery voltage can be logged |
Environment | Waterproof; suitable for deployment in water or air, case materials resistant to fuels, solvents and lubricants. Titanium version recommended for saltwater deployments. |
Operating Range | Temperature: -20°C to 50°C (4°F to 122°F) |
Sample & Event Logging | Samples: Recorded Sensor Measurements Events: Logger Activity (ie: Bad Battery, Host Connected) |
Wetted Materials | Vitron® O-Rings, Acetyle Cap and Ceramic Sensor U20-001-01 Housing: 316 Stainless Steel U20-001-01-TI Housing: Titanium |
Software Compatibility | HOBOware and HOBOware PRO |
OS Compatibility | Windows: Windows 11, 10 and 7 (32 and 64-Bit) Mac: OS X 10.9.x, 10.10.x and 10.11.x |
Operation Indicator | Red LED in Communications Window |
Start Modes | Immediate Start, Programmable Start Time/Date |
Offload Modes | Offload while logging or stop and offload |
Real-Time Clock | ±1 minute per month 0°C to 50°C (32°F to 122°F) |
Standards Compliance | CE |
Weight | 210 g (7.4 oz) |
Dimensions | Logger: 24.6mm D x 150mm L (0.97" D x 5.9" L) Mounting Hole: 6.3mm (0.25") Diameter |