  • Measure and Record Single Phase AC Current and AC Voltage with External Sensors
  • Measurement Range of 0 to 300 Amp AC (Current) and 0 to 500 Volts AC (Voltage)
  • Records onto Internal Memory up to a Total of 21,500 Readings (10,750/ Sensor)
  • 1 Second to 18 Hour User-Selectable Sampling Rate
  • User-Replaceable Battery with 20 to 40 Month Life
  • Includes AC Current Clamp and 4.5 ft Voltage Leads

Requires 9 Volt Battery and LOGiT PC Software Kit

Overview of the Supco LCV Current & Voltage Data Logger

The LCV is part of the LOGiT series of data loggers from Supco and is designed to measure and record AC voltage and current. The LCV can measure AC voltage from 0 to 500 volts and current from 0 to 300 amps. The logger can be used while connected to a PC for real-time data viewing or as a stand-alone data logger. The LCV has onboard memory that can store over 10k data points. Data is viewed and the logger is configured using the LOGiT Software and LINTU interface (both sold separately – Part # LLSU). Recorded data can be viewed in the software or exported as a .CSV file. Sample rates are user selectable from 1 second to 18 hours.

If you don’t already own loggers in the LOGiT series, we would suggest considering the newer Supco DVCV logger.

LOGiT LCV Current and Voltage Logger Specifications

Current
(External Sensor)
Measurement Range: 0 to 300 Amps AC
Accuracy: ±5%
Resolution: 0.1 Amp AC
Voltage
(External Sensor)
Range: 0 to 500 Volts AC
Accuracy: ±1 Volts AC
Resolution: 0.1 Volts AC
Length of Leads: 4.5 ft
Data Storage Capacity 10,750 Readings for Voltage and Current or
21,500 Readings for 1 Channel Voltage or Current
Sampling Rate 1 Second to 18 Hours
Alarms Over and Under Alarms for Current and Voltage
Time Accuracy ±100ppm @ 75°F
Operating Environment Temperature (Alkaline Battery): 0°C to 60°C
Temperature (Lithium Battery): -40°C to 65°C
Humidity: 0% to 95% RH, non-condensing
Storage Environment Temperature: -40°F to 170°F (-40°C to 77°C)
Power Source 9V Alkaline or Lithium Battery (Sold Separately)
Battery Life Alkaline Battery: 20 Months
Lithium Battery: 40 Months
Note: Dependent Upon Environment, Sampling Rate and Battery Type
Calibration Single point offset calibration available through software
OS Compatibility Windows 11, 10 and 7 (32 and 64 Bit)
Dimensions 3" x 2.5" x 1.1" (7.6cm x 6.4cm x 2.8cm)
Weight 1.2lbs (544g)
Customer Questions
Will this log 3 phase current?
This logger is designed for single phase applications.  We have a good selection of 3 phase loggers.  Here is a link to our voltage and current loggers.  Once there please click on the filter for "3-Phase" on the left hand side of the ...
Is the software and needed cabling included?
All the cabling to make your voltage and current connections are included with the logger.  The software and PC connection interface must be purchased separately.  The part number for this kit is LLSU. It can be found on the right hand side...
Regarding the sample rate of 1 second. Is this and exact sample (reading) each second or is it and average of several readings within a second. For example, does the unit software actually read four times in a second then average the four values and record the value as the sample data?
This logger will give you the actual reading at each sample interval.  It does not average the readings over a period like a meter would
How do I see the data? What do I need to see the data?
The data is viewable in the required software which comes with the LLSU software and interface kit - listed under "related items". The software must be installed on a PC and it's used to set up the logger and view the data.
How many samples per cycle does it take?
This particular logger samples at once per second at its fastest recording interval.  This logger is designed to be a low cost option for general purpose recording.  We offer other loggers that sample at higher rates.  Once example would...
If I record one conductor of a parallel feeder, will that give me the whole load of that phase? Or will it be less because of only being clamped to the one conductor?
The LCV logger can only measure a single phase so it would only give you the current of whichever leg of the three phases you are monitoring.  We also offer three phase loggers if that's what you are after.  One I suggest looking at is the ...
Can these meters be set up to do 15 minute averaging as required for measurements in the National Electrical Code?
No.  This logger records only the actual value at the specified user interval.  The fastest it can sample is once per second.  This is good for general power consumption information, it is not a revenue grade meter.
Is there similar product with all specified specification but ac voltage measure upto 1000 volts?
I'm afraid we don't have anything rated up to 1000 volts that I would consider similar to this product. The closest we could recommend looking at that will handle up to 1000 v would be this power meter from AEMC but it is a good deal more expensive: ...
if the battery life is 20 months, do you mean i can leave on for 20 months and the data will log for 20 months' duration?
The battery life shown in the specification is the maximum amount of time that the logger can operate and log data.  Because battery life will greatly vary depending on settings and operating environment the estimates shown should only be used as...
What is the maximum conductor diameter capacity of the clamp?
The opening of the clamp is approximately 1.25" wide by 1.5" tall.