LOGiT LPT Temperature and Pressure Logger Specifications
Pressure (External Sensor) |
Measurement Range: 0 to 500 psi Accuracy: ±3 psi Resolution: 0.15 psi Connection: 1/4" NPT Pressure Sensor Connection |
Temperature (External Sensor) |
Range: -40°C to 65°C (-40°F to 150°F) Accuracy: ±0.5°C (±1.0°F) Resolution: 0.05°C (0.1°F) |
Data Storage Capacity | 10,750 Readings for Temperature and Pressure or 21,500 Readings for 1 Channel Temperature or Pressure |
Sampling Rate | 1 second to 18 hours |
Alarms | Over and Under Alarms for Pressure and Temperature |
Time Accuracy | ±100ppm @ 75°F |
Operating Environment | Temperature (Alkaline Battery): 0°C to 60°C Temperature (Lithium Battery): -40°C to 65°C Humidity: 0% to 95% RH, non-condensing |
Storage Environment | Temperature: -40°F to 170°F (-40°C to 77°C) |
Power Source | 9V Alkaline or Lithium Battery (Sold Separately) |
Battery Life | Alkaline Battery: 19 Months Lithium Battery: 38 Months Note: Dependant Upon Environment, Sampling Rate and Battery Type |
Calibration | Single point offset calibration available through software |
OS Compatibility | Windows XP, Vista and Windows 7 (32-bit and 64-Bit) |
Dimensions | 3" x 2.5" x 1.1" (7.6cm x 6.4cm x 2.8cm) |
Weight | 2.5oz (71g) |
Customer Reviews
Write Your Own Review
Questions
-
Answer:
The 1/4" NPT pressure fitting is made out of stainless steel.
-
Answer:
No, this logger only comes in a 0-500psi version. The pressure sensor can't be changed for a different range.
We offer the Monarch Track-It loggers in a closer range to what you are looking for - https://www.microdaq.com/monarch-instrument-track-it-35psig-gauge-pressure-temp-data-logger.php
-
Answer:
The data is viewable in the Supco software which must be purchased separately. The logger connects to your PC via an interface cable (included with the software kit). The part number for the software and cable kit is LLSU - https://www.microdaq.com/supco-logit-software-usb-kit.php
-
Answer:
The Supco LPT logger can only record gauge pressure. It will not work for barometric pressure.
-
Answer:
The pressure sensor on the logger can be used on anything with a 1/4" NTP fitting.
-
Answer:
If the logger is configured to only record one parameter (temperature or pressure) then you will be able to record 21,500 readings.