MicroDAQ.com
Toll Free: 1-877-275-9606
(603) 746-5524
$5.99 Flat Fee Economy Shipping on Most Items Shipped in the Continental USA

You have no items in your shopping cart.

Subtotal: $0.00

Telaire 7001 Carbon Dioxide CO2 Monitor



Telaire 7001 Carbon Dioxide (CO2) Monitor

CO2 and Temperature Monitor

Part Number: TELAIRE-7001

Ask a question (1)

Be the first to review this product


  • Monitor Carbon Dioxide and Temperature Readings

  • Provides a 0 to 4 Volt Output

  • 0 to 10,000 ppm Carbon Dioxide Measurement on Display

  • 0-4,000 ppm Carbon Dioxide Measurement Output

  • Large LCD Display with Push Button Interface

Availability: In stock

$529.00
$529.00

Carbon Dioxide Monitor Specifications

Performance CO2 Channel
Measurement Range 0-4,000 ppm Voltage Output
0-10,000 ppm Display
Pressure Dependence 0.13% of reading per mm Hg
(Corrected via user input for elevation)
Sensitivity ± 1 ppm
Repeatability ± 20 ppm
Temperature Dependence ± 0.1% of reading per ° or ± 2 ppm per °
whichever is greater, referenced to 25°
Accuracy ± 50 ppm or 5% of reading, whichever is greater
Annual Drift ± 20 ppm typical
Response Time < 60 seconds for 90% of step change
Warm-Up Time < 60 seconds at 22°C
Operating Conditions Temperature:32°F to 122°F (0° to 50°C)
Humidity: 0-95% RH, Non-Condensing
Storage Temperatures -40°F to 140°F (-40°C to 60°C)
Calibration Interval 12 months, offset adjustment using single gas at 0-1000 ppm CO2. Factory calibration available
Temperature Channel
Temperature Range Voltage Output: 32°F to 104°F (0°C to 40°C)
Display: 32°F to 122°F (0°C to 50°C)
Display Resolution 0.1°F (0.1°C)
Display Options °F, °C, or Off. Set with Panel Button
Accuracy ± 2°F (± 1°C)
Response Time 20-30 minutes
(Case must Equilibrate with Environment)
Calibration Interval 12 months, offset adjustment using temperature standard at 50°F to 86°F (10°C to 30°C).
Full factory calibration available
Other Specifications
Method Dual Beam Absorption Infrared™
Sample Method Diffusion or flow through (50 - 100 ml/min)
Output
Analog CO2: 0-4 VDC, 1mV/ppm (4,000 ppm max)
Temperature: 0-4 VDC linear, 32°F to 104°F (0°C to 40°C)
Output Impedance 100 Ohms
Wiring Connection Via RJ-45 to DB9 Serial Port Cable
Display LCD with independent CO2/ temp readings (panel buttons set elevation, °F/°C, calibration functions)
Power Supply
Battery Type Four AA Alkaline Batteries (Not Included)
Battery Operation 80 Hours (alkaline)
External 6 VDC from external AC/DC adapter (included)
Power Requirements 100 mA Peak, 20 mA average from 6V Certification

Customer Reviews

Write Your Own Review

You're reviewing: Telaire 7001 Carbon Dioxide (CO2) Monitor

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Value

  • Answer:

    This is a sensor so it's not actually sampling anything.  The sensor is outputting a linear (fluctuating) 0-4 volt output that will vary depending on the CO2 level.  In order to record this data you must use the optional cable and a data logger (purchased separately).  Once you have it set up you would use the software for the logger to program a sample rate.  The available sample rates vary by logger but generally speaking they are as fast as once per second and go up to once per 18 hours.  Typically for something like CO2 you would sample once per 30min or even once per hour.

Leave a Reply

  • Reload captcha

Ask Your Question

  • Reload captcha

* Required Fields