SRP-006 ACR Systems SmartReader Plus 6 (Cat#01-0013) Data Logger: 8 Channels - Internal Temperature and 7 Thermocouple Inputs



SRP-006 SmartReader Plus 6 Thermocouple Data Logger

ACR 01-0013 8 Channel Logger: One Internal Temperature, Seven Thermocouple Inputs

Part Number: 01-0013

Be the first to ask a question about this product

Be the first to review this product


  • (7) External Thermocouple Inputs and (1) Internal Temperature Sensor

  • Accepts Type J, K, S, T or E Thermocouple Sensor Probes

  • Internal Temperature Sensor Features A Measurement Range of -40°C to 70°C (-40°F to 158°F) and ±0.2°C Accuracy

  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery

  • 25/Second to 8 Hour User-Selectable Sampling Rate

  • Continuous (FIFO) or Stop When Full Sampling Methods

Requires ACR TrendReader 2 Software and USB Cable Kit

Special order - please allow 7-10 business days for this item to ship.

$835.00

All Calibration Orders Have a 5 to 7 Business Day Lead Time
1 Year Calibration Due Date Unless Otherwise Specified

$835.00

SRP-006 ACR Systems SmartReader Plus 6 (Cat#01-0013) Thermocouple Data Logger Specifications

Channels Eight (one internal thermistor for cold-junction compensation and seven for thermocouple inputs)
Memory Available in 32KB (21,500 readings), 128KB (87,000 readings), 1.5MB (1,048,000 readings)
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams (3.75 ounces)
Case Material Noryl Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 25 per second to 1 reading every 8 hrs. Battery Pack (#BP-101) or Power Supply (#PS-201) required for sample rates faster than 8 seconds)
Resolution 12 bit (1 part in 4,096)
Mounting Magnetic backing or locking eyelet
Software Compatiblity Windows 10, 8, 7 (32-bit and 64-bit), Vista (32-bit) and XP (SP3)
Software Requirements TrendReader 2 Software and Interface Kit
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission require ments for the Interference Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5”

 

Thermocouples Accepted
Type Range Resolution
J -50 to 600°C (-55 to 1100°F) 0.30°C (0.55°F)
K -100 to 1150°C (-145 to 2100°F) 0.50°C (0.90°F)
S 0 to 1450°C (32 to 2642°F) 1.0°C (1.8°F)
T -200 to 400°C (-325 to 750°F) 0.40°C (0.75°F)
E -50 to 680°C (-58 to 1250°F) 0.24°C (0.44°F)
Accuracy: ± 0.5% of range + resolution

 

Internal Temperature Sensor
Type Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F)
Accuracy ± 0.2°C, over the range of 0 to 70°C(±0.3°F over the range of 32 to 158°F)
Range -40 to 70°C (-40 to 158°F)
Resolution 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C(0.12°F) between -25°C (-13°F) and 70°C (158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F)

You may also be interested in the following product(s)

USB Serial Adapter

USB Serial Adapter

  • Plugs into any Available USB Port on a Windows PC
  • Provides one RS-232 Male DB9 Port for Direct Connection to Serial Devices
  • Draws Power from the USB Connection - No Power Adapter Required
  • 0°C to 40°C (32°.F to 104°.F), 0-95% RH Operating Range
  • Includes Adapter, 85cm Cable(33"), CD and Quick Start Guide
Learn More
$31.00
SRP-DM Display Module

SRP-DM Display Module

  • Provides a Display for Critical Control Points Throughout the Manufacturing Process
  • Verification and Spot Checking
  • Portable, Battery Powered and Easy to Use
  • View Real-Time Channel Data When you Want
  • Optional Power Supply for Continuous Visual Display (Sold Separately)
Learn More
$545.00
ACR Systems PS-201 Network and Fast Sampling Power Supply

ACR Systems PS-201 Network and Fast Sampling Power Supply

  • Required When Network Length is Greater than 50ft or More Than (3) Loggers on the Same Network
  • Works as A Power Supply for Fast Sampling
  • Compatible with the ACR SmartReader Plus Data Loggers
  • Available in European or US Adapter Versions

Includes "Y" Splitter (01-0098)

Learn More
$69.00
Versions

Customer Reviews

Write Your Own Review

You're reviewing: SRP-006 SmartReader Plus 6 Thermocouple Data Logger

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Quality
Value

There are no product questions yet.

Ask Your Question

  • Reload captcha

* Required Fields